3003 W CASINO RD 2017 BLDG 40-56 Plans 2025-03-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-56
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-56 Plans 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 2:39:00 PM
Creation date
12/20/2018 2:05:37 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-56
Permit
B1708-018
Year
2017
Notes
INSTALL NEW CLOSED LOOP HOLD DOWN , VACUUM PUMP, COOLING TOWER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FUNCTION B�OCKS — FUNCTION DESIGNATIONS P 8c ID �INE NUMBER IDENTIFICATION P �C ID INSTRUMENT TERMINOLOGY <br /> N0. FUNCTION SYMBOL DEFINITION XX��- XXX- X -XX - X-X FIRST LETTER SUCCEEDING LETTER(S) <br /> 1 SUMMING � THE OUTPUT EQUALS THE ALGEBRAIC SUM OF THE INPUTS (THE INPUTS MAY BE � <br /> � LABELED WITH POSITIVE OR NEGATIVE SIGN) TRACING TYPE MARK <br /> MEASURED OR MODIFIER READOUT OR OUTPUT MODIFIER <br /> INSULATION TYPE AND THICKNESS INITIATING VARIABLE PASSIVE FUNCTION FUNCTION <br /> 2 AVERAGING ��� THE OUTPUT EQUALS THE ALGEBRAIC SUM OF THE INPUTS DIVIDED BY THE PIPE/MATERIALS SPECIFICATION <br /> NUMBER OF INPUTS A ANRLYSIS ALARM <br /> MATERIAL CODE B BARRIER <br /> 3 DIFFERENCE a THE OUTPUT EQUALS THE ALGEBRAIC DIFFERENCE OF THE TWO INPUTS ANSI FLANGE CLASS � <br /> C CONDUCTIVITY CONTROL <br /> ❑ LINE NUMBER D DENSITY DIFFERENTIAL/DEVIATION <br /> THE OUTPUT IS DIRECTLY PROPORTIONAL TO THE INPUT. IN THE CASE OF A FLUID SERVICE E VOLTAGE ELEMENT/ SENSOR <br /> 4 PROPORTIONAL 1 ;1 VOLUME BOOSTER, "K" MAY BE REPLACED BY 1;1 FOR INTEGER GAINS, 2:1, 3:1, LINE SIZE (NOMINAL) F FLOW RATE RATIO <br /> " ETC, MAY BE SUBSTITUTED FOR K <br /> 2:1 G GROUND GLASS, GAGE <br /> P 8c ID PIPE FLUID SERVICE P �C ID PIPE MATERIAL CODE H HAND (MANUAL INITIATE) HIGH <br /> 5 INTEGRAL � THE OUTPUT VARIES IN ACCORDANCE WITH BOTH MAGNITUDE AND DURATION OF <br /> THE INPUT. THE OUTPUT IS PROPORTIONAL TO THE TIME INTEGRAL OF THE INPUT AA ATOMIZING AIR CODE MATERIAL I CURRENT (ELECTRICAL) INDICATE <br /> THE OUTPUT IS PROPORTIONAL TO THE RATE OF CHANGE DERIVATIVE OF BD BLOWDOWN A HIGH ALLOY J POWER SCAN <br /> 6 DERIVATIVE d df � ) <br /> THE INPUT BFW BOILER FEED WATER C CARBON STEEL K TIME TIME RATE CONTROL <br /> CA COMPRESSED AIR D DUCTILE IRON OF CHANGE STATION <br /> 7 MULTIPLYING � THE OUTPUT EQUALS THE PRODUCT OF THE TWO INPUTS CF CHEMICAL FEED G GALVANIZED STEEL L LEVEL LIGHT LOW � <br /> CWR COOLING WATER RETURN I CAST IRON M MOISTURE MOMENTARY MIDDLE <br /> 8 DIVIDING a THE OUTPUT EQUALS THE QUOTIENT OF THE TWO INPUTS CWS COOLING WATER SUPPLY K COPPER N <br /> ROOT n� THE OUTPUT EQUALS THE ROOT (I.E. CUBE ROOT, FOURTH ROOT, 3/2 ROOT, ETC) DR DRAIN (PUMPED OR GRAVITY) M MALLEABLE IRON 0 ORIFICE <br /> 9 EXTRACT OF THE INPUT. IF n IS OMITTED, A SQUARE ROOT IS ASSUMED FO FUEL OIL N NON-METALLIC P PRESSURE/VACUUM POINT (TEST) CONNECTION <br /> GAS NATURAL GAS S STAINLESS STEEL Q QUANTITY INTEGRATE <br /> 10 EXPONENTIAL Xn THE OUTPUT EQUALS THE INPUT RAISED TO A POWER (I.E. SECOND, THIRD ETC.) HPC HIGH PRESSURE CONDENSATE TOTALIZE <br /> HPS HIGH PRESSURE STEAM R RADIATION RECORD <br /> NONLINEAR OR IA INSTRUMENT AIR S SPEED/ FREQUENCY SAFETY SWITCH <br /> 11 UNSPECIFIED f(x) THE OUTPUT EQUALS SOME NONLINEAR OR UNSPECIFIED FUNCTION OF THE INPUT LPC LOW PRESSURE CONDENSATE P & I D P I P E AN S I FLAN G E C LASS T TEMPERATURE TRANSMIT <br /> FUNCTION <br /> LPS LOW PRESSURE STEAM A 2500 U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION <br /> , 12 TIME FUNCTION f�t� THE OUTPUT EQUALS THE INPUT TIMES SOME FUNCTION OF TIME OR MPC MEDIUM PRESSURE CONDENSATE B 1500 V VIBRATION VALVE/ DAMPER <br /> EQUALS SOME FUNCTION OF THE TIME ALONE <br /> MPS MEDIUM PRESSURE STEAM C 900 MECHANICAL ANALYSIS LOUVER <br /> 13 HIGH SELECTING � THE OUTPUT IS EQUAL TO THE GREATER OF THE INPUTS PCWR PROCESS COOLING WATER RETURN D 600 W WEIGHT/ FORCE WELL <br /> PCWS PROCESS COOLING WATER SUPPLY E 300 X UNCLASSIFIED X AXIS UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED <br /> 14 LOW SELECTING � THE OUTPUT IS EQUAL TO THE LESSER OF THE INPUTS SA ATOMIZING STEAM F 150 Y EVENT/ STATE Y AXIS RELAY/ COMPUTE <br /> SW SEAL WATER G 125 OR PRESENCE CONVERT <br /> 15 HIGH LIMITING � THE OUTPUT EQUALS THE INPUT OR THE HIGH LIMIT VALUE WHICHEVER IS LOWER VT VENT Z POSITION/ DIMENSION Z AXIS DRIVER/ACTUATOR , <br /> 16 LOW LIMITING � THE OUTPUT EQUALS THE INPUT OR THE LOW LIMIT VALUE WHICHEVER IS HIGHER WA RAW WATER P 8c I D P I P E I N S U LATI 0 N TYP E FINALACONTROL . <br /> ❑ WT SOFT WATER TREATED ELEMENT <br /> . H HEAT CONSERVATION <br /> �� REVERSAL � THE OUTPUT IS REVERSELY PROPORTIONAL TO THE INPUT P 8c I D P I P E T RAC I N G TY P E <br /> PROPORTIONAL P PERSONNEL PROTECTION <br /> ET ELECTRIC TRACING BLANK UNINSULATED <br /> THE OUTPUT EQUALS THE THE INPUT AS LONG AS THE RATE OF CHANGE OF THE ST STEAM TRACING <br /> P�CID GENERAL INSTRUMENT OR FUNCTION SYMBOLS <br /> 18 VELOCITY LIMITER � INPUT DOES NOT EXCEED A LIMIT VALUE. THE OUTPUT WILL CHANGE AT THE RATE GT GLYCOL TRACING <br /> ESTABLISHED BY THIS LIMIT UNTIL THE OUTPUT AGAIN EQUALS THE INPUT WT WATER TRACING MOUNTED INSIDE MAIN PANEL LOCAL PANEL LOCAL PANEL FIELD <br /> BLANK NO TRACING MAIN PANEL OPERATOR MOUNTED INSIDE FACE MOUNTED MOUNTED � <br /> OPERATOR ACCESSIBLE OPERATOR OPERATOR <br /> � INACCESSIBLE INACCESSIBLE ACCESSIBLE <br /> 19 BIAS a THE OUTPUT EQUALS THE INPUT PLUS (OR MINUS) SOME ARBITRARY VALUE (BIAS) MAN UAL LY 0 P E RAT E D VALVE D E S I G NATO R S P �C I D L I N E AN D P I P I N G <br /> . � SYMBOLS IDENTIFICATION <br /> —Da— DISCRETE <br /> 2-V1OO PROCESS/SERVICE LINE (NEW) INSTRUMENTS <br /> THE FORM OF THE OUTPUT SIGNAL IS DIFFERENT FROM THAT OF THE INPUT VALVE SIZE � �— VALVE PROCESS/SERVICE LINE (EXIST.) <br /> * * SPECIFICATION <br /> E- VOLTAGE H - HYDRAULIC <br /> LWE BY OTHERS (NIC) (PLC) <br /> 20 CONVERT * * � - CURRENT 0 - ELECTROMAGNETIC, SONIC P �C I D M I S C E L LAN E 0 U S I N ST R U M E N T • ' • MECHANICAL LINK PROGRAMABLE _ _ _ _ _ _ <br /> � P- PNEUMATIC R - RESISTANCE (ELECT.) �f�f PN EUM A TI C LI N E <br /> A- ANA L O G R O L E R ONT- <br /> B- BINARY D - DIGITAL ���_ <br /> CAPILLARY TUBING <br /> FI <br /> ROTAMETER - - - - - - - ELECTRIC SIGNAL COMPUTER <br /> � � STATE 1 X 5 H THE OUTPUT HAS DISCRETE SIGNAL FUNCTION - - - <br /> ** H DISCRETE STATES WHICH — o o SOFTWARE OR COMMUNICATIONS LINK <br /> STATE 2 (ENERGIZED OR ALARM STATE) X > H ARE DEPENDENT ON THE FE <br /> STATE 1 (ENERGIZED OR ALARM STATE) X < L VALUE OF THE INPUT. � -� HYDRAULIC SIGNAL <br /> 2� SIGNAL ** � SHARED <br /> MONITOR STATE 2 X > � wHEN THE INPUT "o ELECTROMAGNETIC SIGNAL (GUIDED) � <br /> EXCEEDS (OR BECOMES FLOW ELEMENT DISPLAY, - - - - - - • <br /> STATE 1 (FIRST OUTPUT M� ENERGIZED OR ALARM STATE) X < L LESS THAN) AN -- UNIT BOUNDARY / EQUIPMENT PACKAGE SHARED _ <br /> ** HL STATE 2 (BOTH OUTPUTS INACTIVE OR DE-ENERGIZED) L S X 5 H ARBITRARY I.IMIT VALUE, Xx CONTROL) <br /> THE OUTPUT CHANGES XXXX XXXX � <br /> STATE 3 (SECOND OUTPUT M2 ENERGIZED OR ALARM STATE) X > H STATE. DIRECT —�" PIPE SPECIFICATION CHANGE <br /> CONNECTION (ANY - <br /> INSTRUMENT) � POINT OF CONNECTION (OR INTERFACE WITH <br /> TE <br /> POC XXXX OTHERS) <br /> EXAMPLE LOOP TEMPERATURE ELEMENT <br /> W/0 THERMOWELL <br /> SOFTWARE OR DATA LINK -,� �� SET POINT TE <br /> �_�_ o SP <br /> PRES. ALARM HIGH � PRESSURE INDICATING CONTROLLER TEMPERATURE ELEMENT <br /> o WITH THERMOWELL � <br /> CONTROL VARIABLE <br /> ELECTRICAL SIGNAL FE <br /> I�- o — PALL PoH PIC �V - - - - - <br /> IN-LINE FLOW ELEMENT <br /> PAL 1001 <br /> DIR PV B�M I <br /> PRES. ALARM LOW LOW � <br /> PLC IDENTIFIER P 8c ID — VALVE AND LINE ABBREVIATIONS PLC IDENTIFIER TAG NUMBER IDENTIFICATION <br /> PASSED TO WTERLOCK I I INSTRUMENT <br /> I/P � AIR SUPPLY <br /> PRES. ALARM LOW PIT —PROCESS PY ' <br /> DIRECT DIR OR 1001 VARIABLE 1001 �� A'S' DC DRAIN CONNECTION CCS COMBUSTION CONTROL SYSTEM EQUIP P-1234A �a��" "` -0� �� � <br /> �"' � �� ��a � <br /> � � FC FAIL CLOSED 0 �' � �: � <br /> REVERSE (REV) CONTROL � ZT _ _ _ ZI ZA FL FAIL LAST INSTR. TE * � • -� �'� --� 6 � �`'°:� <br /> 1001 1001 FO FAIL OPEN BMS BURNER MANAGEMENT SYSTEM 1234A � <br /> 4"-LPC-099-FC25-H2" 1/2-V500 HB H05E BIB(CONNECTION) * = THIS INSTRUMENT IS IDENTIFIED AS A SAFETY INTEGRITY LEVEL (SIL) G R � � P <br /> HV HAND VALVE BOM BALANCE OF MODULE DEVICE WHICH IS PART OF THE BURNER MANAGEMENT SYSTEM (BMS). NO <br /> HXE ELECTRIC HEATER MODIFICATIONS OF ANY KIND ARE ALLOWED WITHOUT AUTHORIZATION. 6OO St�yl/�I"t St., St� ��OO <br /> � 3"-LPC-100-FC25-H2" PV-1001 LO LOCKED OPEN S@at��� W�shington 9�101 <br /> LC LOCKED CLOSED (IF REDUNDANT OR SUBPART A,B,C, ETC.) � <br /> MR MANUAL RESET INSTRUMENT OR EQUIPMENT N0. I SS U E D FO R P E RM I T ���'� <br /> NO NORMALLY OPEN j'��;. �@� 206.267.1700 <br /> BOILER N0. 1 THRU 6, 0 IF COMMON TO MODULE ���� <br /> P- 1001 NC NORMALLY CLOSED � � 7 Q '�%��#,��" Fax 206.267.1701 <br /> MODULE N0. (1, 2 OR 3, 0 IF SITE COMMON) O / . � V. � � �� <br /> SAZAN #500-1775 <br /> SYM REVISION BY APPROVED DATE SYM REVISIQN BY APPROVED DATE � ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> � LA� THIS DESIGN AND/OR �HE�KEo P&ID LEGEND AND A��REVIATIONS W2572915 — 07.� 8.� � <br /> - IRC ROUTER VAC PUMP H20 RECYCLE W2572915 SAZAN 07.18.17 ��� o� ��'�sff �y; � <br /> �� , �,-,�� SPECIFICATION IS APPROVED sHEET <br /> ,� � s CJ %.'i���1r'�� APPROVED BY DEPT. DATE N IN TITLE IRC — WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE . <br /> r � M1 - 1 <br /> ��� "�� s`'i��'�,��� x£�,,,..� CHECKED <br /> �F�� ��GI�Ex�° �ti�� �UI�DING 40m056 �og N0. COMP No. <br /> �� � APPROVED <br /> ��Na�L� <br /> 07/17/2017 APPROVED MECHANICAL MASTER COL. X—X/X—X EVERETT owc No. 40-056—M 1 -1 —scratch <br />