Laserfiche WebLink
SYMBOL ABBREVIATION DESCRIPTION DOUBLE LINE DUCTWORK LEGENQ SINGLE LWE DOUBLE LINE DUCTWORK LEGEND SINGLE LINE ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION <br /> [ PIPE CAP SUPPLY OUTLET, CEILING TYPE, DIFFUSER A COMPRESSED AIR (100 PSIG NOM.) °F DEGREES FAHRENHEIT R RETURN OR EXHAUST REGISTER <br /> ��— BF BLIND FLANGE RECTANGULAR DUCT, FIRST NUMBER X X SD 12/12 AC AIR CONDITIONING UNIT F FILTER RA RETURN AIR <br /> X/X INDICATES SIZE OF SIDE SHOWN 400 CFM �SD), GRILLE (SG) OR REGISTER (SR), • <br /> SQUARE OR RECTANGULAR AD ACCESS DOOR FAI FRESH AIR INTAKE RAD REFRIGERATED AIR DRYER <br /> c-f— 90° ELBOW DOWN AD PR ACCESS DOOR PRESSURE RELIEF FAT FINAL AIR TEMPERATURE RF RETURN FAN <br /> X� RETURN/EXHAUST REGISTER (RR), GRILLE � � <br /> o� 9(� ELBOW UP X� � ROUND DUCT, NUMBER INDICATES DIAMETER RG 12/12 �RG) CEILING DUCT TYPE, SQUARE OR ACFM ACTUAL CUBIC FEET PER MINUTE FD FLOOR DRAIN RH RELIEF HOOD <br /> �� OUTLET (TEE) DOWN 100 CFM RECTANGULAR AFF ABOVE FINISH FLOOR FL FLOQR �RH RELATNE HUMIDITY <br /> DUCT SHOWN W SECTION ARROW POINTS SUPPLY OUTLET, CEILWG TYPE, AHU AIR HANDLING UNIT FLA FULL LOAD AMPERAGE RLA RUNNING LOAD AMPERAGE <br /> X/X AMB AMBIENT FLEX FLEXIBLE CONNECTION RM ROOM <br /> -+� OUTLET (TEE) UP <br /> .F- TO SIDE CALLED OUT FIRST (SUPPLY) � DIFFUSER (SD), GRILLE (SG), ROUND AP ACCESS PANEL FO FLOOR OPENING RPM REVOLUTIONS PER MINUTE <br /> -��c� PIPE OFFSETTING DOWN X X D 10 400 FM APD AIR PRESSURE DROP FOB FLAT ON BOTTOM RV RELIEF VALVE <br /> � (W/RESPECT TO ARROW) � �j� DUCT SHOWN IN SECTION, ARROW POINTS <br /> . --��- PIPE FLANGE I�� TO SIDE CALLED OUT FIRST EXHAUST ARR ARRANGEMENT FOT FLAT ON TOP <br /> � � LINEAR DIFFUSER AND AIR FLOW RATE AS AIR SEPARATOR FOV FUEL OIL VENT S SUPPLY DIFFUSER OR REGISTER <br /> = PIPE GUIQE SUPPLY AIR DUCT, SQUARE OR RECTANGULAR 100 CFM AUX AUXILIARY FPM FEET PER MINUTE SA SUPPLY AIR <br /> ANC PIPE ANCHOR ELBOW TURNING TOWARDS T " AWT AVERAGE WATER TEMPERATURE FS FREEZE STAT SCFM STANDARD CUBIC FEET PER MINUTE <br /> � TEMPERATURE / HUMIDITY SENSORS FUD FUNNEL FLOOR DRAIN SD SMOKE DETECTOR <br /> �� PIPE HANGER DUCT MOUNTED BDQ GRAVITY BACK DRAFT DAMPER SD SUPPLY DIFFUSER <br /> SUPPLY AIR DUCT, SQUARE OR RECTANGULAR BOD BOTTOM OF DUCT . GA. GAUGE SF SUPPLY FAN <br /> � � FLEXIBLE CONNECTOR ELBOW TURNING AWAY X�X LINED DUCT (DIMENSIONS FOR NET BOP BOTTOM OF PIPE GAL. GALLON SM SHEET METAL ' <br /> EXPANSION JOINT EXHAUST AIR DUCT, SQUARE OR RECTANGULAR FREE AREA) BOT BOTTOM GC GENERAL CONTRACTOR SP STATIC PRESSURE <br /> �WL ELBOW TURNING TOWARDS BOS BOTTOM OF STEEL GPH GALLONS PER HOUR SPEC SPECIFICATIONS <br /> -p-- CONCENTRIC REDUCER BTU BRITISH THERMAL UNIT GPM GALLONS PER MINUTE SP.GR. SPECIFIC GRAVITY <br /> � EXHAUST AIR DUCT SQUARE OR RECTANGULAR SOUND ATTENUATOR (SPECIFY SIZE, SQ SQUARE <br /> -�-'r ECCENTRIC REDUCER � LENGTH AND ATTENUATION) C COMMON HC HEATING COIL SR SUPPLY REGISTER <br /> �- FLOW ARROW ELBOW TURNING AWAY C CONDENSATE RETURN (GRAVITY) HDV HOLD DOWN VACUUM SS STAINLESS STEEL <br /> CAP CAPACITY HORIZ HORIZONTAL ST SOUND TRAP <br /> ��F- UN UNION „��;,�,, ROUND DUCT, ELBOW TURNING CC COOLING COIL HP HORSE POWER STM STEAM � <br /> � TOWARD � CENTRIFUGAL FAN CD CONDENSATE DRAIN HPC CONDENSATE, STEAM (HIGH PRESSURE) SV STEAM VE'�NT <br /> --���- FLOWMETER, ORIFICE <br /> ROUND DUCT, ELBOW TURNING CFH CUBIC FEET PER HOUR HPS STEAM SUPPLY (HIGH PRESSURE, <br /> � AV ANGLE VALVE � CFM CUBIC FEET PER MINUTE 125-250 PSIG) , <br /> AWAY � CENTRIFUGAL FAN, INLET GUIDE VANES CHWR CHILLED WATER RETURN HR HOUR T STEAM TRAP <br /> �o- GV GATE VALVE CHWS CHILLED WATER SUPPLY HPWR HOT PROCESS WATER RETURN MOP WATER TA TRANSFER AIR <br /> -►f- GV GATE VALVE (NORMALLY CLOSED) CLG CEILING HPWS HOT PROCESS WATER SUPPLY �MOP WATER� TD TEMPERAT,URE DIFFERENCE <br /> -D�- GLV GLQBE VALVE TRANSITIONS, RECTANGULAR TO TERMINAL UNIT (SINGLE DUCT UNIT SHOWN) CLV VACUUM, CLEANWG HWC HOT WATER CIRCULATING, DOMESTIC TEMP TEMPERAT,URE <br /> , � RECTANGULAR CO CLEANOUT HWR HEATING WATER RETURN (TO 250 �C 160 PSIG) TG TRANSFER GRILLE <br /> -� GLV GLOBE VALVE (NORMALLY CLOSED) CONC CONCRETE HWS HEATING WATER SUPPLY (TO 250 �C 160 PSIG) To� TOP OF DUCT <br /> fi� CV CHECK VALVE STANDARD BRANCH FOR SUPPLY AND COND CONDENSATE HX HEAT EXCHANGER TOM TOP OF MEZZANINE <br /> -lr'F- BFV BUTTERFLY VALVE RETURN (NO SPLITTER DAMPER) CONT. CONTINUATION TOP TOP OF PIPE <br /> �- DIAPHRAGM VALVE TRANSITION AT TAKE-OFF CONTR. CONTRACTOR V HAND VA VE TOS TOP OF STEEL � <br /> CS COLD SPRING B TSP TOTAL STATIC PRESSURE <br /> -�VF- PV PLUG VALVE SPLITTER DAMPER CRU CONDENSATE RETURN UNIT TYP TYPICAL <br /> ���- BV BALL VALVE TRANSITION, SQUARE OR RECTANGULAR (INDICATE SPLIT DIMENSIONS) CTR COOLING TOWER RETURN ID INSIDE DIAMETER <br /> TO ROUND CTS COOLING TOWER SUPPLY IE INVERT ELEVATION <br /> -I�I- BV BALL VALVE (NORMALLY CLOSED) CUH CABINET UNIT HEATER IN INCHES UH UNIT HEATER <br /> DUCT OFFSET UP OR DOWN —�- DUCTWORK AIR FLOW DIRECTION CV CONTROL VALVE IW INDUSTRIAL WATER UST UNDERGROUND STORAGE TANK <br /> . -� CIRCUIT SETTER/ EUP (ARROW SHOWS CHANGE OF ELEVATION CW COLD WATER, DOMESTIC <br /> , �- BALANCING VALVE IN DIRECTION OF AIR FLOW) C/C DR COOLING COIL DRAIN KW KILOWATT V VENT <br /> —�- FAN, AXIAL FLOW VAC VACUUM, HARD <br /> . PSV PRESSURE RELIEF/SAFETY VALVE � OPPOSED BLADE DAMPER � D DAMPER LAT LATENT VD VOLUME DAMPER <br /> � ��20 12 Y LB POUND W VARIABLE AIR VOLUME BOX <br /> -Dj� NEEDLE VALVE 2� 00 CFM LOUVER, DOOR OR WALL DH DOOR H ATER LDB LEAVING DRY BULB VEL VELOCITY <br /> � P A R A L L E L B L A D E D A M P E R DIA DIAMETER L P C L O W P R E S S U R E C O N D E N S A T E VERT VERTICAL <br /> Q UC 1 2" UNDERCUT DOOR (SHOW CLEAR HEIGHT OF UNDERCUT DN DOWN LPS STEAM SUPPLY VP VELOCITY PRESSURE <br /> -D'� SOL2- 2-WAY SOLENOID VALVE 200 CFM IN INCHES AND FLOW RATE) DR DRAIN LRA LOCKED ROTOR AMPERAGE VP VACUUM �UMP DISCHARGE <br /> VOLUME DAMPER �� � DG 12 6 LVG LEAVING VTR VENT THRU ROOF • <br /> SOL3- 3-WAY SOLENOID VALVE VD VD VD � DWG. DRAWING LWB LEAVING WET BULB <br /> DOOR GRILLE <br /> DUCT DAMPER, MOTOR OPERATED 100 CFM LWT LEAVING WATER TEMP. <br /> . Q � (ELECTRIC OR PNEUMATIC, SHOW EA EXHAUST AIR W WIDTH <br /> --D� CV2- 2-WAY CONTROL VALVE pM PARALLEL OR OPPOSED BLADE DAMPER) EAT ENTERING AIR TEMPERATURE WB WET BULB <br /> PNEUMATIC OPERATOR TG 24 12 TRANSFER GRILLE ASSEMBLY EC ELECTRICAL CONTRACTOR MAT'L MATERIAL W.G. WATER GAUGE <br /> � BACKDRAFT DAMPER (ALLOWS EDB ENTERING DRY BULB MAX. MAXIMUM WH WATER HEATER <br /> CV3- 3-WAY CONTROL VALVE � �' 1000 EF EXHAUST FAN MBH 1000 BTU PER HOUR WPD WATER PRESSURE DROP <br /> PNEUMATIC OPERATOR BDD FLOW IN DIRECTION OF ARROW) <br /> � �. CEILING RETURN GRILLE WITH EFF EFFICIENCY MC MECHANICAL CONTRACTOR WTD WATER TEMP DROP <br /> CV2- 2-WAY AUTOMATIC CONTROL VALVE � 90° ELBOW EFT ELECTRIC FIN TUBE RADIATION MCC MOTOR CONTROL CENTER WxL WIDTH x �LENGTH <br /> ELECTRIC OPERATOR � AD ACCESS DOOR (AD) OR ACCESS PANEL (AP) <br /> EG EXHAUST GRILLE MECH MECHANICAL <br /> AD EL. ELEVATION MFR. MANUFACTURER p P PRESSURE DIFFERENCE <br /> CV3- 3-WAY AUTOMATIC CONTROL VALVE FD FD �► � �-► TRANSFER GRILLE, DUCT CONNECTED <br /> ELECTRIC OPERATOR AD FIRE DAMPER (1 HOUR) ELECT ELECTRICAL MID MIDDLE � PERCENTAGE . <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM MIN. MINIMUM * FIELD VERIFY <br /> _�, PRV PRESSURE REDUCING VALVE FD2 FD2 � MECHANICAL RETURN GRILLE/REGISTER ENT ENTERING MOD MOTOR OPERATED DAMPER ** VERIFY WITH APPROVED <br /> PILOT OPERATED AD FIRE DAMPER (2 HOUR) ER EXHAUST REGISTER MTD MOUNTED EQUIPMENT SHOP DRAWINGS <br /> , � PRV PRESSURE REDUCING VALVE � MECHANICAL SUPPLY DIFFUSER ESP EXTERNAL STATIC PRESSURE <br /> SELF CONTAINED ET EXPANSION TANK <br /> , SD SD . <br /> AQ SMOKE DAMPER —~CFM SUPPLY OR OUTSIDE AIR FLOW DIRECTION EWB ENTERING WET BULB N/A NOT APPLICABLE <br /> EWT ENTERING WATER TEMP. NC NORMALLY CLOSED <br /> PI PRESSURE GAUGE WITH VALVE XXX RETURN, TRANSFER OR EXHAUST NIC NOT IN CONTRACT <br /> �, RECTANGULAR DUCT, SQUARE ELBOW, SHOWN ��CFM AIR FLOW DIRECTION NO NORMALLY OPEN <br /> -�-�+ STR STRAINER (WYE TYPE) � WITH TURNING VANES T WALL MOUNTED THERMOSTAT NOM. NOMINAL <br /> STR STRAINER WYE TYPE � NTS NOT TO SCALE <br /> � � ) QT N NIGHT THERMOSTAT O.A. OUTSIDE AIR <br /> WITH BLOW OFF RECTANGULAR DUCT, RADIUS E�BOW, SHOWN �T UNIT MOUNTED THERMOSTAT OBD OPPOSED BLADE DAMPER <br /> STRAINER, DUPLEX � WITH TURNING VANES �H CEILING DUCT MOUNTED HUMIDISTAT O.C. ON CENTER <br /> g � OPER OPERATING <br /> a WAL� MOUNTED TEMPERATURE <br /> T SENSOR/TRANSMITTER P PUMP <br /> TC TEST PLUG �' EXTRACTION GRID SP WALL MOUNTED STATIC PRESSURE PCWS PROCESS COOLING WATER SUPPLY <br /> SENSOR/TRANSMITTER B PCWR PROCESS COOLING WATER RETURN <br /> SP DUCT MOUNTED STATIC PRESSURE P <br /> TI THERMOMETER, LINE MOUNT SENSOR/TRANSMITTER PHC PREHEAT COIL <br /> FLEXIBLE DUCT �'VI� - -�'VI�� PRESS PRESSURE <br /> STATIC PRESSURE REGULATOR PRV PRESSURE REDUCING VALVE <br /> PW PROCESS WATER (CW PROTECTED BY BFP) '. <br /> ' TI THERMOMETER, SEPARABLE WELL MOUNT �IIIII� FLEXIBLE DUCT CONNECTION � WALL MOUNTED SWITCH <br /> � SD 12 6 SIDEWALL SUPPLY AIR DIFFUSER (SD), QH WALL MOUNTED HUMIDISTAT ,QTY QUANTITY <br /> � �- STEAM TRAP �I100 CFM GRILLE (SG) QR REGISTER (SR) (NOTE <br /> ELEVATION AS REQUIRED) 4s DUCT TYPE DETECTOR, SMOKE <br /> �v AAV AUTOMATIC AIR VENT RD 12/6 SIDEWALL RETURN/EXHAUST AIR GRILLE � <br /> � MAV MAV MAN A AIR V NT WITH HOSE END �I100 CFM (RG/EG), OR REGISTER (RR/ER) {NOTE 4H DUCT TYPE DETECTOR, HEAT <br /> �TAV U L E ELEVATION AS REQUIRED) <br /> cu x�z <br /> �.�,,,,� ; � ��4 ��� <br /> TAV THERMOSTATIC AIR VENT WITH HOSE END I12�/6_ SCREENED OPENING � TEST PORT ,n,,y <br /> � 100 CFM (NOTE ELEVATION AS REQUIRED) � � ,m�A �� � �,� <br /> BFP BP BACKFLOW PREVENTER � DUPLEX AIR DROP � <br /> REDUCED PRESSURE TYPE � STUB-UP DUPLEX FLOOR MOUNTED AIR OUTLET (NOT IN TRENCH) G R O U P <br /> TRANSITION AFTER TAKE-OFF A DUPLEX VACUUM DROP OUTLET 600 Stewart St., Ste 1400 <br /> -� UH UNIT HEATER � � <br /> � � DRY AIR OUTLET Seattle, Washington 98101 <br /> -C QUICK DISCONNECT FITTING, FEMALE ISSUED FOR PERMIT Tel 206.267.1700 <br /> �7. � 8. 17 �F Fax 206.267.1701 <br /> SAZAN # 500-1775 <br /> SYM REVISION BY APPROVED DATE SYM REVISION 8Y APPROVED oarE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL D DATE <br /> �. L,, W2572915 L� 07.18.17 <br /> �� , THIS DESIGN AND/OR CHECKED MECHANICAL LEGEND <br /> �,�� oF �ti�ls�f� cS <br /> � A MOP #3 — RECORD 13365026 HGI SEL 03.28.14 �� 3 ��r�� SPECIFICATION IS APPROVED SHEET <br /> . B IRC — WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE W2572915 SAZAN 07.18.17 BOE,�� � � J €� j2� N �N TITLE IRC — WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE M 1 <br /> c �r,r APPROVED BY DEPT. DATE <br /> ;:� l�� �`�_� �. �„Mr CHECKED <br /> � � � �,��' ���� ������ BUILDING 40-056 <br /> �O�' ��`��'`��'�'�� �`��� APPROVED JOB N0. COMP N0. <br /> � �'��ION,L ��` � W2572915 <br /> ��� APPROVED DWG N0. <br /> 07/17/2017 MECHANICAL MASTER EVERETT, WA 40-056-M1 <br />