|
1
<br /> .INSULATION AND-FENeST1 ATION REOUIREMENTS,.R40211; Vertical Fenestration(Windows and doors)
<br /> GENERAL NOTES Component Width Height Sill
<br /> CLIMATE ZONE Inch Inch Inch
<br /> CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR Description Ref. U-factor Qt. Feet Feet Feet Area UA
<br /> TO COMMENCING THE WORK. FENESTRATION U-FACTOR Ikl (N)D1-LITE-DOOR WSEC 0.30 1 3 0 6 8 20.0 6.00
<br /> WORK SHALL COMPLY WITH THE FOLLOWING CODES: <
<br /> 2015 INTERNATIONAL RESIDENTIAL CODE SKYLIGHT U-FACTOR IM 0.50 (N)D2-LITE/FOLDING-DOOR WSEC 0.30 1 12 6 6 8 83.3 25.00 K
<br /> 2015 WASHINGTON ENERGY CODE GLAZED FENESTRATION SHGC(k,e) (N)D3-SLIDING-DOOR WSEC 0.30 1 8 2 6 8 54.4 16.33 o m
<br /> OTHER CODES APPLICABLE BY JURISDICTION. a y
<br /> CEILING R-VALUE 161 44
<br /> AIR SEALING: WOOD FRAME WALL R-VALUE Id 21 INT Sum of Vertical Fenestration Area and UA 157.8 47.33 o a
<br /> 1. ALL PLUMBING,ELECTRICAL,AND HVAC PENETRATIONS IN FLOOR, MASS WALL R-VALUE(dl Vertical Fenestration Area U=UA W21 hied
<br /> WALLS,AND CEILINGS ARE CAULKED AND SEALED. FLOOR R-VALUE 9 /Area 0.30 F N
<br /> 2. WHERE PENETRATIONS NEED A FIRESTOP,DISCUSS WITH BUILDING BELOW-GRADE WALL R-VALUE le,cl Total SumFenestration Area and UA o
<br /> OFFICIAL. - of (for heating system sizing calculations) 157.8 47.33
<br /> 3. ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR WALLS SLAB 8-VALUE&DEPTH Ig,hl ' 10,2FT
<br /> MUST BE SEALED AT THE BACK OF THE RECEPTACLE OR SEALED WITH
<br /> FACEPLATE GASKETS. ENERGY REQUIREMENTS FOR ALTERATION AND ADDITIONS,PRESCRIPTIVE WINDOW&DOOR SCHEDULE NOTES:
<br /> 4. SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT LIKE APPROACH(SEATTLE)-SEC TABLE R402.1.1 1. XO=SLIDER,NH =SINGLE HUNG,DH=DOUBLE HUNG,FIX= PICTURE,
<br /> TYVEK"ON EXTERIOR. a. R-VALUES ARE MINIMUMS.U-FACTORS AND SHGC ARE MAXIMUMS. C=CASEMENT
<br /> 5. VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS,4 MIL. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN 2. IF CONTRACTOR DECIDES TO REPLACE WINDOWS,THEY MUST MEET f
<br /> VISQUEEN OR AN APPROVED VAPOR BARRIER PAINT. THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE ENERGY PERFORMANCE STANDARDS,HEAT TREATMENT
<br /> SEPARATION BETWEEN DWELLING AND GARAGE/CARPORT: COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE REQUIREMENTS AND EGRESS REQUIREMENTS.
<br /> a. NO SEPARATION REQUIRED ENTIRELY OPEN ON 2 OR MORE SIDES A101.4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE 3. ALL WINDOWS SHALL BE NFRC CERTIFIED.
<br /> AND NO SES. IFEPEN DECKS ABOVE ARE OKAY.NON-RATED TABLE.THE VALUES IN ITEMS B.THROUGH H.BELOW APPLY TO 4. CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT YEN DESIGN INC
<br /> WALLS AND ENCLOSEDOPENALE WINDOWS BETWEEN THE DWELLING AND ALTERATIONS AND ADDITIONS,AND ARE FOR WOOD FRAMING ONLY- REQUIREMENTS WITH WINDOW b DOOR MANUFACTURER.
<br /> METAL FRAMING NOT ALLOWED UNDER PRESCRIPTIVE APPROACH. FOR 5. CONTRACTOR TO VERIFY WINDOW AND DOOR DIMENSIONS PRIOR TO WWW.YENDES.COM
<br /> CARPORT ARE OKAY). ALTERATIONS ONLY,WHERE EXISTING FRAMING REMAINS AND THE ORDERING WINDOWS.
<br /> b. MINIMUM 1/2"GWB ON GARAGE/CARPORT SIDE OF WALLS REQUIRED FOR 6. EGRESS WINDOWS SIZED FOR"MILGARD STYLE LINE"SERIES 1622 NE 179TH ST.
<br /> ALL GARAGES/CARPORTS NOT COVERED BY IA ABOVE. FRAMING CAVITY IS EXPOSED DURING CONSTRUCTION,THE CAVITY MUST WINDOWS.CONTRACTOR TO VERIFY EGRESS REQUIREMENTS IF A SHORELINE,WA,98155
<br /> c. 1-HOUR FIRE RATED WALL REQUIRED IF LESS THAN 5 FEET FROM BE FILLED WITH INSULATION.WHERE THE FRAMING CAVITY IS NOT DIFFERENT MANUFACTURER/MODEL IS CHOSEN.
<br /> PROPERTY LINE No OPENINGS ALLOWED LESS THAN 3'FROM PROPERTY EXPOSED DURING CONSTRUCTION,NO ADDITIONAL INSULATION IS PHONE(206)432-1111
<br /> REQUIRED.WHERE NEW FRAMING IS INSTALLED,FULL INSULATION IS
<br /> LINE,257.MAXIMUM OPENINGS BETWEEN 3'AND 5'TO PROPERTY LINE). REQUIRED AS SPECIFIED BELOW: INSULATION CERTIFICATE(SEATTLE) APPROVAL STAMP
<br /> OVERHANGS MUST BE A MINIMUM 2'FROM PROPERTY LINE,EXCEPT b. MIN.CEILING INSULATION=R-49 IR-38 IF FULL THICKNESS OF
<br /> STEEL GUTTER ALLOWED CLOSER AND 5/8"GWB SHEATHING REQUIRED INSULACONTRRESIDENTIALACTOR SHALL COMPLETEIAND POST 3'AO INSULATIONTHEE CERTIFICATE
<br /> PANEL
<br /> ON UNDERSIDE WHEN 5'OR LESS FROM PROPERTY LINE. ORJOIST-VION EXTENDS OVER THE WALL TOP PLATE)FOR SINGLE RAFTER FOR OFINALONTION WITHIN OF THE ELECTRICAL PANEL
<br /> JOIST-VAULTED CEILINGS,THE [NSULAITON MAY BE REDUCED TO PRIOR TO FINAL INSPECTION.
<br /> R-EGRESS WINDOWS:REQUIRED FOR 1 WINDOW/BEDROOM OR SLEEPING AREA INT.
<br /> (BELOW 4TH FLOOR)AND 1 WINDOW/BASEMENT. c. INT.(INTERMEDIATE FRAMING)DENOTES STANDARD MIOF 16 INCHES
<br /> ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF 5-10 AIR LEAKAGE(SEATTLE):
<br /> a. MIN.NET CLEAR AREA= 5.7 SQ.FT.,(MIN.3'0"x 4'6"IF DOUBLE HUNG INSULATION.LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE A WRITTEN REPORT OF THE TEST RESULTS,SHALL BE SIGNED BY THE
<br /> OR 4'0"x 3'6"WINDOW IF SLIDER). 5.0 SQ.FT.IF SILL HEIGHT IS THICKNESS OF 3.5 INCHES ARE EXEMPT FROM THE INSULATION TESTING PARTY AND PROVIDED TO THE BUILDING INSPECTOR,PRIOR TO
<br /> WITHIN 44"OF GRADE(ABOVE OR BELOW). REQUIREMENT. CALL FOR FINAL INSPECTION.
<br /> b. MIN.NET CLEAR OPENING WIDTH=20';MIN NET CLEAR OPENING d. MIN ABOVE-GRADE"MASS WALL"INSULATION(TYPICALLY CONCRETE OR
<br /> HEIGHT=24" CMU)= R-21 CAVITY OR R-21 CONTINUOUS.THE SECOND R-VALUE HIGH EFFICACY LAMPS
<br /> a. MAX.SILL HEIGHT=44"(ONE PERMANENTLY INSTALLED STEP WITH APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIRO A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN
<br /> MAX.8"RISE AND MIN.9"RUN OKAY FOR EXISTING BEDROOMS). OF THE MASS WALL. LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
<br /> e, "10/15/21•TB"MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR
<br /> REQUIRED GLAZING FOR HABITABLE ROOMS: OF THE WALL,OR R-15 CONTINUOUS INSULATION ON THE INTERIOR OF
<br /> a. MIN.GLAZED EXTERIOR OPENING AREA =85 OF FLOOR AREA. THE WALL,OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK
<br /> b. GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY INSTALLED BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF
<br /> ARTIFICIAL LIGHT IS PROVIDED. THE BASEMENT WALL"10/15/21•TB"SHALL BE PERMITTED TO BE MET
<br /> c. OK IF OPENINGS ARE BELOW DECK 6 ROOFED PORCHES w/MIN.CEILING WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT OTHER REQUIREMENTS:
<br /> HEIGHT OF 7 FT.(LONG SIDE 655 OPEN). WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR a. GUARDRAILS:MIN.36"HT.MAX.4"SPACING BETWEEN IY
<br /> EXTERIOR OF THE WALL."TB"MEANS THERMAL BREAK BETWEEN FLOOR INTERMEDIATE MEMBERS(42"MIN.HT.FOR R-2 EXTERIOR). O
<br /> MECHANICAL/VENTILATION:REQUIRED FOR HABITABLE ROOMS OF ADDITIONS SLAB AND BASEMENT WALL. b FLOORINGS: BOTTOM MIN.12"BELOW GRADE,TOP OF FOUNDATION
<br /> AND ALTERATIONS MORE THAN 500 SQ. FT.OR THAT INCLUDE A KITCHEN, f. MIN.FLOOR INSULATION ABOVE UNHEATED SPACE =R-30 WALL MIN.6"ABOVE GRADE. w W
<br /> BATHROOM AND OTHER AREAS WHERE COOKING ODOR OR EXCESS WATER g. MIN.PERIMETER INSULATION FOR UNHEATED SLAB ON GRADE = R-10 c. CONCRETE SLABS ON GRADE:3-1/2"MIN.THICKNESS. O
<br /> VAPOR WILL BE PRODUCED. UNDER ENTIRE SLAB PLUS R-1O FOR 2 FEET H. PIER BLOCKS: MIN.12"X 12"SIZE; RESTING ON CONCRETE PAD MIN.
<br /> a. MIN.50 CFM FOR BATHROOM AND LAUNDRY;MIN.100 CFM FOR h. MIN.INSULATION FOR HEATED SLAB ON GRADE= R-IO UNDER ENTIRE 12"BELOW GRADE. w Z
<br /> KITCHEN. SLAB PLUS R-10 PERIMETER INSULATION.SEE R402.2.9.1 OF THE WSEC. e. FOUNDATION WALLS:PROVIDE ONE (1)#4 REBAR TOP AND BOTTOM w LU
<br /> b. MIN.AIR INTAKE OPENINGS= 4 SQ.IN.PER ROOM. i. MAX.WINDOW AND DOOR(FENESTRATION)U-FACTOR=U-30.THERE ARE AND AT ALL WINDOWS/DOOR OPENINGS.LIMIT 4'MAX.BACKFILL. Q ret
<br /> c. WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN INC M1507.3 NO SHGC REQUIREMENTS IN THE MARINE ZONE.
<br /> j. IN ANY ONE DWELLING UNIT(INCLUDING BOTH NEW AND EXISTING f. FOUNDATION ANCHOR BOLTS:MIN.1/2"X 10",6 FT. ON CENTER IY
<br /> SMOKE ALARMS:REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS AND ON MAX.WITH TWO)2)BOLTS PER PIECE OF PLATE AND AT LEAST (n Z
<br /> PORTIONS),ONE SIDE-HINGED DOOR UP TO 21 SQ FT PLUS UP TO 15 SQ AT END OF EACH PIECE REQUIRED FOR z CD
<br /> ONE(11 BOLT WITH 12"
<br /> ALL FLOORS. DIRECT WIRING IS REQUIRED FOR SMOKE DETECTORS,UNLESS �J,J w >
<br /> REQUIREMENTS.
<br /> FT OF GLAZED FENESTRATION CAN BE EXEMPT FROM U-VALUE O
<br /> REMOVAL OF INTERIOR WALL OR CEILING FINISHES IS NECESSARY TO NEW CONSTRUCTION(. > >
<br /> INSTALL THE WIRING. g ALL STRUCTURAL SOFTWOOD PLYWOOD,PARTICLE BOARD,WAFER Q - 03 N
<br /> k. MAXIMUM SKYLIGHT U-FACTOR=0.50.THE FENESTRATION U-FACTOR BOARD,AND OSB BOARD ARE STAMPED WITH EXPOSURE'1'OR Z [J,J 4 w 9
<br /> COLUMN EXCLUDES SKYLIGHTS.THE SHGC COLUMN APPLIES TO.ALL O
<br /> CARBON MONOXIDE ALARMS:REQUIRED OUTSIDE SLEEPING AREAS AND ON ALL GLAZED FENESTRATION. 'EXTERIOR'. f- Z U J a
<br /> FLOORS,UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES OF THE h. WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L
<br /> I. OTHER:ADD NOTES FOR ENERGY CERTIFICATE(R401,31),DUCT LEAKAGE I71rn w Y
<br /> BUILDING. APPLIANCE ENERGY CONSERVATION ACT.ASHRAE STANDARD rn V 0 m
<br /> TESTING IF FURNACE REPLACED IR1OI.4.3.11 90A-1980 INSULATION TO R-l6 OR 5-10 PAD IF LOCATED OVER ¢ L] H
<br /> STAIR REQUIREMENTS:(APPLIES TO ALL R-3 STAIRS AND R-2 PRIVATE m. SEATTLE ENERGY CODE,ALTERATIONS:PROVIDED THE ENERGY USE OF UNINSULATED SLAB. U Q w
<br /> THE BUILDING IS NOT INCREASED,EXISTING CEILING,WALL OR FLOOR - tr
<br /> STAIRWAYS): (. INSULATE HOT AND COLD WATER PIPES TO R-3 IN UNHEATED w Q O `. w
<br /> CAVITIES EXPOSED DURING CONSTRUCTION MAY BE FILLED WITH o J F W w
<br /> a. MIN.WIDTH =36" INSULATION.2X4 WALLS SHALL BE INSULATED TO A MINIMUM OF R-15. AREAS. <
<br /> b. MAX.HEIGHT/RISE =7-3/4"; MIN.TREAD RUN =10" J. SHOWER REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2.5 GPM
<br /> c. MIN.HEADROOM= 6'8" FOUNDATION LOCATION: PROPERTY CORNERS MUST BE ACCURATELY k. WOOD STOVES AND FIREPLACES HAVE TIGHT FITTING DOORS,
<br /> d. HANDRAIL 34"-38"ABOVE TREAD NOSING(RETURN ENDS) DETERMINED AND INDICATED ON SITE FOR FOUNDATION INSPECTION.A OUTSIDE COMBUSTION AIR DUCTED TO FIREBOX WITH ACCESSIBLE -J
<br /> e. HANDRAIL GRASP DIMENSION:MIN.1-1/4",MAX.2" SURVEY MAY BE REQUIRED.FENCE LOCATIONS WILL NOT BE ACCEPTED AS DAMPER,MIN 6 SQ IN FREE VENT AREA.TIGHT FITTING FLUE J
<br /> F. WINDING STAIRS: ESTABLISHING PROPERTY CORNERS. DAMPERS REQ'D. o D
<br /> 1.MIN.TREAD RUN AT NARROWEST POINT 6" I, ALL GAS AND OIL COMBUSTION APPLIANCES HAVE A DIRECT VENT a o
<br /> 2.MIN.TREAD RUN 12"FROM NARROWEST POINT=10" OR FORCED DRAFT VENTING. Z W
<br /> g. SPIRAL STAIRS: r6 FIRE SEPARATION m. RECESSED LIGHTS ARE I.C.RATED,DOUBLE WALL CAN LIGHTS OR _
<br /> 1.MIN.CLEAR WALKING AREA WIDTH =26" A. 1-3/8"SOLID-CORE WOOD,1-3/8"SOLID OR HONEYCOMB STEEL,OR 20 WITHIN SEALED WPGWB BOX-IN. U
<br /> 2.MIN.TREAD RUN 12"FROM NARROWEST POINT =7-1/2"/ MIN.RATED GARAGE /DWELLING DOOR EQUIPPED WITH A SELF-CLOSING U)
<br /> DEVICE. W
<br /> MAX.RISER HEIGHT=9-1/2" B. MIN.1/2"GYPSUM WALLBOARD AT GARAGE WALLS AND 5/8"TYPE X W o
<br /> 3.MIN.HEADROOM = 6'6" GYPSUM BOARD CEILING SEPARATING GARAGE FROM DWELLING IF
<br /> APPLICABLE. lb O
<br /> CEILING HEIGHT IN ADDITIONS AND ALTERATIONS (SEATTLE): C. MIN.1/2"GYPSUM WALLBOARD WRAPPING POSTS, BEAMS AND WALLS Z ❑
<br /> a MIN.TO":FOR NEW CONSTRUCTION OR ADDITIONS SUPPORTING THE DWELLING ABOVE THE GARAGE IF APPLICABLE, «f
<br /> b. MW.6'4":IF BUILDING WAS IN EXISTENCE PRIOR TO 10/17/79(SEE DR Q
<br /> 23-2008 FOR SPECIFICS)
<br /> CC
<br /> c. ROOMS WITH SLOPED CEILINGS REQUIRE MINIMUM CEILING HEIGHT IN W
<br /> 1/2 OF THE AREA.(PORTIONS OF THE ROOM WITH CEILING HEIGHT Z
<br /> LESS THAN 5 FT.DO NOT COUNT IN TOTAL AREA). LLI
<br /> INSULATION:
<br /> 1. FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING MEMBERS DRAWN BY Z.P.M.
<br /> 2 ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED
<br /> INSULATION,INCLUDING ALL CAVITIES ISOLATED DURING FRAMING, DESIGNER T.R.Y.
<br /> WIRING,AND PLUMBING. REVIEWER A.N.Y.
<br /> 3, ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID BOARD - N"_, JOB NO. Y-17-010
<br /> INSULATION BEHIND THEM.
<br /> 4. UNDER-FLOOR INSULATION IS SUPPORTED BY LATH,TWINE,OR OTHER erl !;``� SCALE SEE SHEET
<br /> NON-COMPRESSING MEANS. l7 // 1 SHEET OF10
<br /> 5. ATTIC ACCESS i5 BAFFLED,WEATHER-STRIPPED AND INSULATED. , 6�/ A1 . 1 1 . 1
<br />
|