Laserfiche WebLink
• <br /> 66'-120 <br /> 2'-84" 2'-5k 12'-8" 14'-5k 3'940 5'-104" 344" 20'-410 LEGEND <br /> :An 1'-114" rq" 3i-10n 1'"4" <br /> 3' 3'840 8" 8' 5'-9k" .40 4,4" 9i„ • 5'-780 12'-60 2'-9n 11.1 NEW STUD WALL G <br /> I////1 EXISTING WALL TO REMAIN o <br /> ___11-I DEMOLISHED WALLS <br /> U � <br /> ••••• • NEW BEAM w w <br /> o a <br /> SD SMOKE DETECTOR n <br /> w <br /> a ' <br /> o <br /> �__/,� INDICATES REFERENCE TO KEYNOTES SEE o <br /> l.J KEYNOTES ON THIS SHEET FOR BALANCE <br /> Q OF INFORMATION o <br /> III 11111 <br /> EW DECK 0 = CD CARBON MONOXIDE DETECTOR WITH <br /> BATTERY BACKUP. 10 <br /> - <br /> 4 <br /> �' s,� EF EXHAUST FAN(INTERMITTENT) <br /> 0 III I <br /> 111 5� ,„'+‘ x;F DX INDICATES NEW WINDOWS/DOORS, SEE SHEET A7.1 FOR <br /> �1 as WINDOWS/DOORS SCHEDULE. YEN DESIGN INC <br /> PLAN KEYNOTES <br /> -e-.1 <br /> diN <br /> P.s <br /> 7. BEARING WALLS TO BE REMOVED WWW.YENDES.COM <br /> NOOK a 1622 NE 179TH ST. <br /> D2pp 2. WINDOW OR DOOR TO BE INFILLED PER SHEET A1.1- SHORELINE,WA,98155 <br /> .. /��,,,.. .... /®� INSULATION AND FENESTRATION REQUIREMENTS <br /> Is_uI <br /> _�I `... .. I%///////////////// �I///////////////////Io1r/-.� /���%////� PHONE 1206)432-1111 <br /> r 3. PROVIDE 5inx12"GLULAM 24F-V4 HEADER,13'L w/ <br /> \ (4)2x_STUDS WEST END AND 1312x_STUDS NORTH END APPROVAL STAMP <br /> 7 4. NEW GUARDRAIL PER MANUFACTURER SPEGIF[CATION, <br /> i IN MI III AM © SEE SHEET 52.4 FOR GUARDRAIL REQUIREMENTS <br /> 1, <br /> 1 . <br /> �aca, TR DW 7 1, "' S. 1/8"DECK BOARD SPACING <br /> lk1111111mmi, 2 04/ i DINING'I 7e -\ 6. ALL TRUSS FRAMING ROOF LOAD TRANSFERS INTO <br /> �,,,', r\ 'l ' A 6 • -� EXTERIOR WALLS AND INTO FOUNDATION BELOW <br /> � I%//////////` ROOMKITCHEN <br /> / 7. PROVIDE 51/8"x12"GLULAM 24F-V4 HEADER,8'-6"L w/ <br /> A �� \ ',, -- EF • i I` LIVING MI 0 1312x_STUDS EA.END <br /> '\__J 1 OCFM �, f1 Ell <br /> ROOM <br /> % GENERAL NOTES <br /> QA II <br /> - .._. —,®1---- — �II A. SEE SHEETA1.1FORCOMMONCODEREQUIREMENTS. <br /> - 8,-2�„ 5 0„ III _ <br /> 3' 18'"30 i B. CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL <br /> 113 MASTER ,,�r ,, ,�.._--_�1 / ? _II �' LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO <br /> BEDROOM A II5 % SLEEPING AREAS. <br /> 110� // --,`�,, - G SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF COFFEE/� 32' , 32 '.■.ITHE DWELLING AND WITHIN EACH SLEEPING AREA.DIRECT <br /> w% EF ` -,300 `"12 M1�0--------- FRZR REFR WIRING REQUIRED. E W <br /> „ 1 PWDR \` _� r ��PNTi"GOAT D DOOR MANIUFACTURER.NDOW& OR ROUGH OPENING SIZES WITH WINDOW& ZV <br /> SD O �, 240 E. ALL DIMENSIONS TO FINISHED WALL. ce O W <br /> 600 /� I_I '/ 4 89 3'-: `° _ W - W <br /> Kms/ ,I 1viiiiiiiiiiiiiii�l A.. ,',/ <br /> //----ii;- -I- r„�z,�,�,��- --, 4izzz�� -_\ F. CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO z <br /> 360 .e- _ SD CD , �' \ CONSTRUCTION. W w O <br /> --I 24” = z �N/ <br /> 6'-tan 6'-6" - FOYER % j Q G. CONTRACTOR TO DETERMINE d VERIFY ALL WASTE DIVERSION Q cc Q Qp , <br /> 1.1 <br /> -- A - A RAISE FLOOR B TLERS" I, REQUIREMENTS PER THE LOCAL JURISDICTION.CONTRACTOR MAY z Q G o <br /> / EF / / �/ /% 11111 <br /> �_..P� \ BE REQUIRED TO REQUEST LEED REPORTS FROM RECEIVING O W - w g <br /> I / % /-- - 'NTRY % - FACILITIES. J ~ a <br /> o Iii <br /> 11O MASTER OFFICE - � ROOM IIII 30"FAMILY 1 �\ \ H. <br /> DOORS <br /> WITHOUT ASA PLACEMENT <br /> IADIMENSIONS WILL BE 3"OFF WALL Q V Z 2 <br /> BATHROOM ID' —r 4W 1im/rry \\30" <br /> I <br /> I. YEN DESIGN IS TO BE CONTACTED IF ACTUAL EXISTING O Q w a j <br /> _ -A-� - iii <br /> A1 <br /> . <br /> MI% FRAMING PLAN ASSUMPTIONS AFTER CEILING WALL COVERINGS < -J I- .- w <br /> MUD�' ARE REMOVED/_\ —, <br /> iimili, <br /> r.,--.3-2';, Ill t <br /> I II <br /> -re <br /> T 2'-6" 0'-62� MAIN FLOOR GARAGE IS UNCHANGED AND \ 1 3 1- -iit, <br /> DLD imm o <br /> .o \NOT SHOWN FOR CLARITY _ w 1 AI LJJ <br /> o p jal_E- <br /> (E) <br /> GARAGE J //, \ Z <br /> i, A (787 SF) IA ''' o Q <br /> 1 <br /> 4,-110 q�.1p2 2' it,' 2' 2' 2 q2"10i"L, 2'-31„ 'iii. <br /> 4'-1" 6' 2 2 2 6 <br /> 14'-220 12'-30 7.110 7'-60 15'-4" 9' yI I <br /> / / /-- / — .. - DRAWN BY Z.P.M. <br /> DESIGNER T.R.Y. <br /> L REVIEWER A.N.Y. <br /> PROPOSED MAIN LEVEL FLOOR PLAN EXISTING MAIN FLOOR PLAN 0' 4' 8' 16' 32' -4111111111,11111) JOB NO. Y47-010 <br /> O� 1� 2' 4' SCALE SEE SHEET <br /> 22x34:SCALE 1/16"=1'-0" SHEET OF 10 <br /> 22x34:SCALE 1/4"=1'-0" I 11x17:SCALE 1/32"=1'-0" <br /> 11x17:SCALE 1/8"=1'-0" elf <br /> A2. 1 <br />