PER SCHEDULE PER SCHEDULE PER SCHEDULE � PER SCHEDULE i PER SCHEDULE �PER SCNEDULEi � PER SCHEDULE � � PER SCHEDULE �
<br /> Door Schedule I -2721 12th St
<br /> Door Frame
<br /> � i i 2721 Door Fire Hardware
<br /> , , � � � � Unit# Number Size Descritpion Depth Type Finish Rating Glazing Group Comments �
<br /> � � � � r,,`,Y�-,,v Width Height Thickness Type Finish �
<br /> W � / / CV
<br /> w m ° w ' w ' � - w � Ground Floor 1 -4
<br /> � � � �� � � ,� � ,' o � � � � � � - 1+4-001 2'-6" 6'-8" 0'-1 3/4" B PAINT PRE-HUNG EXTERIOR UTILITY 0'-51/8" 1 PAINT - - 6 NO VIEWER,KEYED DOOR LATCH �
<br /> � w v z � Q z � ' _ � _ � w - � `" w� 1 1 1+4-1.1 3'-0" 6'-8" 0'-1 3!4" A PAINT PRE-HUNG UNIT ENTRY 0'-51/8" 1 PAINT - - 1 VIEWER AT+60"AFF N
<br /> v � c..� w z t-- � v c) v v = _ �
<br /> cn w ¢ � � o ¢ w � � � � � v� v � c..> � 1 1+4-1.2 2'-6° 6'-8" 0'-1 3/4" Y PAINT CLOSET 0'-4 1/2" - PAWT - - 2 LOWERED DOOR AT W/D � 6'
<br /> W J
<br /> w � � o �� �= w C° w � w �� � w � �Z � 2"TRIM w 1 1+4-1.3 4'-0" 6'-8" 0'-1 3/8" D PAINT CLOSET BY-PASS - PAINT - - 4 �
<br /> � � c�i� � �� ¢ w w � � � � � � °' °- � 1 1+4-1.4 2'-6" 6'-8" 0'-1 3/4" C PAINT BEDROOM PRIVACY 0'-4 1/2" - PAINT - - 5 - � �
<br /> `n H � C� � � L c�
<br /> � �� � > Q �� `� � 1 1+4-1.5 4'-0" 6'-8" 0'-1 3/8" D PAINT CLOSET BY-PASS - PAWT - - 4 �' �
<br /> _ �
<br /> - PAINT - - 5 n �t,_.. m �
<br /> _
<br /> - ¢ � ¢ I� -�- 1 1+4-1.6 2'-4" 6'-8" 0'-1 3/4" C PAINT BATHROOM PRIVACY 0'-4 1/2"
<br /> >
<br /> INSULATED FIBERGLASS FIBERGLASS HOLLOW CORE WOOD WOOD BI-PASS WOOD HOLLOW METAL FRAME WOOD FRAME AT GYPSUM WALL BOARD 1 1+4-1.7 2'-6" 6'-8" 0'-1 3/4" C PAINT BEDROOM PRNACY 0'-4 1/2" - PAINT - - 5 � �
<br /> [GALVANIZED AT EXTERIOR [AT RESIDENTIAL SUITES, WRAPPED OPENWG 1 1+4-1.8 4'-0" 6'-8" 0'-1 3/8" D PAINT CLOSET BY-PASS - PAINT - - 4 - � �
<br /> OO O O LOUVERED PANEL O CONDITIONS� TRIM PROFILES VARY] AT BI-PASS DOORS 1 1+4-1.9 2'-6" 6'-8" 0'-1 3/4" C PAWT BEDROOM PRNACY 0'-4 1/2" - PAINT - - 5 `' .�. � �
<br /> FOR VENTILATION FRAME TYPE 1 FRAME TYPE 2 FRAME TYPE 3 1 1+4-1.10 4'-0" 6'-8" 0'-1 3/8" D PAINT CLOSET BY-PASS - PAINT - - 4 � .� �
<br /> Door T es Do�r Frame T �G.7 3 1+4-3.2 2'-6" 6'-8" 0'-13/4" Y PAINT CLOSET 0'-41/2" - PAINT - - 2 LOUVEREDDOORATW/D � o
<br /> �� �;" 3 1+4-3.7 2'-6" 6'-8" 0'-1 3/4" Z PAINT CLOSET 0'-4 1/2" 2 PAINT - - 2 WATER HEATER ACCESS DOOR IN NEW FRAME ` ` � �
<br /> ����-\�� Upper Floor 1 -4 - ° � M
<br /> � � 2 1+4-2.1 3'-0" 6'-8" 0'-1 3/4" A PAINT PRE-HUNG UNIT ENTRY 0'-5 1/8" 1 PAINT - - 1 VIEWER AT+60"AFF � ';-
<br /> Tvpical Door Schedule Notes Z 1+4-2.2 2'-6" 6'-8" 0'-13/4" Y PAWT CLOSET 0'-41/2" - PAINT - - 2 LOWEREDDOORATW/D � M '
<br /> - - - - - - - - EXISTING EXTERIOR WALL-NEW SIDING 1X6 PRESSURE TREATED ��``',''�''w�"', .��-• ,�` .� �
<br /> FRAP�IE WITH 1!4"MESH • REPLACE ALL HAND SETS AT ALL EXTERIOR AND INTERIOR DOORS 4 1+4-4.2 2'-6" 6'-8" 0'-1 3/4" Y PAINT CLOSET 0'-4 1/2" - PAINT - - 2 LOUVERED DOOR AT W/D L h
<br /> � �3 • WITH LEVER-TYPE HAND SETS ��"'"�'� 4 1+4-4.7 2'-6" 6'-8" 0'-1 3/4° Z PAINT CLOSET 0'-4 1/2" 2 PAINT 2 WATER HEATER ACCESS DOOR IN NEW FRAME ` ¢ C9
<br /> - NEW CEMENTITIOUS PLANK SIDING SCREEN LEVER ' � o
<br /> - NEW 1 1/2"WIDE FURRING STRIPS CENTERED ON HARDWARE ' �N H E R E E X I ST I N G EN T RY DOORS ARE REPLACED REPLACE DOOR, � �, -
<br /> AND ATTACHED TO EXISTING WOOD STUDS. DEPTH � VARIES � WATER-PROOF DOOR FRAME,AND HARDWARE � °-
<br /> OF FURRING AS REQUIRED TO ALIGN FINISHES 12"TO 24" CAULK ALL • VERIFY ALL FRAME DEPTHS
<br /> - EXISTING EXTERIOR SHEATHING AROUND • WHERE EXISTING EXTERIOR UTILITY ROOM DOORS ARE REPLACED
<br /> REPLACE DOOR,DOOR FRAME,AND HARDWARE ���� ��. '�.�€�r��'
<br /> SSUMED 1 HOUR FIRE-RATED _ ExisTiN�2x4 sru�s aT�s"O.C. • REPLACE HINGES AS ALL NEW INTERIOR AND EXTERIOR DOORS s����;;, ..
<br /> E� EQUIVALENT AT EXISTING UNIT - EXISTING BATT INSULATION
<br /> DEMISING WALLS - ExisriN�5is"GYPSUM WALL BOARD �
<br /> w i 54'-4" i t
<br /> . . � - �°��,�:)1. r���+t�sf;i'e{f'?f�
<br /> � BUILDING TYPE 1 ������'����'=y'=����*'�'�': �
<br /> 2721 -2727 -2733 � -� .
<br /> ' � A B
<br /> ' EXISTING 2X4 STUDS REMOVE EXISTING WOOD DRILL HOLE IN CONCRETE STEM QUANTITY VARIES- � _
<br /> AT 16"O.C. SIDWG AND BUILDING PAPER WALL FOR WATER HEATER 9 PER 4-PLEX ' ' ^,
<br /> OVERFLOW 18 PER 8-PLEX W
<br /> EXISTING TO EXPOSE EXISTING PIPE WHERE OCCURS VERIFY IN FIELD / � � a - � _ + - � - � - � � _ � o � � - � � i � � � � � - � � � � � - � - � � � � - � � � - � � - - � � ` �
<br /> 5/8"GWB \ GYPSUM SHEATHING
<br /> EXISTING BATT � _� 5�"$�� I 42'-5" � I � O
<br /> INSULATION - - - ;�`� -`_ �_-_ -' �'- - �4_., _ � �
<br /> REMOVE AND DISCARD EXISTING VENT �
<br /> � I REPLACE ALL CRAWL SPACE VENTS ALL I
<br /> .;• - WHERE OCCURS,CUT EXISTING HOT WATER E2 �
<br /> � TANK OVERFLOW PIPE AS REQUIRED.INSTALL I ' ' � A30 AROUND BUILDING.SEE TYPICAL CRAWL � ! �
<br /> ',-',
<br /> �� COUPLING AND EXTEND PIPE THRU CONCRETE I SPACE VENT DETAIL THIS SHEET.VERIFY I �
<br /> ,��` WALL WITH 90 DEGREE ELBOW DOWN � � LOCATION AND QUANTITY IN FIELD , �
<br /> � 2"MINIMUM FROM FACE OF BUILDING I I I � �
<br /> , - -'s =- ----- =-- - -- � - -�- - - - -__ --- G I � - - - - - - - - - - - - - - - - - - - - - - - � �
<br /> - - - - - - - - - - - � T icalCrawlS aceVent � � �' � � � � � �
<br /> EXISTING 1/2" ............. r ' ( I I � • •
<br /> GYPSUM SHEATHING � NEW TOILET- I ( � '
<br /> TYPICAL 4 LOCATIONS INSTALL NEW BATH FAN
<br /> EXISTING VINYL WINDOW TO ( REPLACE EXISTING AT EXISTING LOCATION � �
<br /> NEW CEMENTITIOUS i BUILDING TYPE 1 � EXISTING UNIT - E2 I �
<br /> PLANK SIDING CLIPPED REMOVE EXISTING REMAIN WITH NAIL FIN I ELECTRIC WATER HEATER-
<br /> TO NEW BATTENS VINYL SIDING,TRIM ATTACHED THRU EXISTING TYPICAL 4 LOCATIONS DEMISING WALL
<br /> �Yrwti,_ 1/4"INSULATION BOARD � � BUILDWG TYPE 1 BE�2 TYPICAL 4 LOCATIONS I �
<br /> � AND ATTACHMENT BUILDING TYPE 1
<br /> NEW 1 1/2"WIDE PRESSURE AND 1X FURRING TO REMAIN
<br /> TREATED PLYWOOD STRIPS - SYSTE����� w�f-�-��� � I BED 1 \ BED 3 BED 1 , � U
<br /> CENTERED ON AND ATTACHED TO INSTALL DRIP EDGE AT �; REFINISH EXISTING TUB �
<br /> �ROVIDE CONTINUOUS- WINDOW HEAD � , I I I
<br /> EXISTING STUDS-DEPTH OF BLOCKING AT JOINT ' ^
<br /> FURRING AS REQUIRFD AS REQUIRED � 1+4-1.8 AND INSTALL NEW SHOWER
<br /> TO ALIGN FINISHES �J��J \� 4"WIDE CEMENTITIOUS I SURROUND,VALVES AND I I LJ�
<br /> , !� TRIM ALL AROUND i TRIM-TYPICAL 4 LOCATIONS NEW COUNTER TOP,SPLASH �
<br /> I BUILDING TYPE 1 BASE CABINET LAVATORY AND I �
<br /> Z HEAD CONDITION SIMILAR I � WH 1+4-1.7 ' 1+ 14� FAUCET-TYPICAL4LOCATIONS . � �
<br /> Z ' I - BUILDING TYPE 1 I I
<br /> . . . . � I 3A � - - - 1+�4 - - - - - - - - - - �\ 1+4-3.5� �� - - - - - �+� - - - 3B \ I I �
<br /> � � A601 � � - - - - - - - - � - - - - - 1 �
<br /> T�pical Siding Detail at Window Jamb UNIT1 � � 1+4-��9 - - � 1+4-3.4 A601 �
<br /> I I �+4-1.4 - -� - - --- - � � - - - - - - I UNIT3 I I i"1
<br /> `�J �
<br /> �/ - � - - - - � - - - -- � 1+4-1.6 ` � - '- - - T- - - -I , - - - - - - � � p�
<br /> � � � �- � - - ! - - � � � � - - - - � � � I O
<br /> A ( t3 _ � U� REF. ' ' 1+4-1.3 B�QTH A � 1+4-3.3 � REF. � � ' � � �' �
<br /> � � ( I O'� ( I \ � I I _ � � I � 4 � � N ��
<br /> _ 54'-4" M �_A30 I DINING KITCHEN A ( I � I BATH B I I KITCHEN B � I 1-A30 0 � � `
<br /> REPLACE EXISTING DOWNSPOUTS AT � N ��
<br /> ' ' � ° 'I " - - � - � I � NEW REFRIGERATOR- DINING I � � O
<br /> , SELECT LOCATIONS IDENTIFIED BY OWNER ( NEW RANGE AND HOOD FAN. I I I TYPICAL 4 LOCATIONS I � �
<br /> I AT SELECTED BUILDINGS(TYPICAL) ( USE EXISTWG VENT PATH- _ _� � _� � BUILDWG TYPE 1 � , � � �
<br /> , ( TYPICAL 4 LOCATIONS � r I ' I I I � � � �.+ �
<br /> I BUILDING TYPE 1 � � � � � , W/D , ' � -� � U �+ �'�/
<br /> , � I '-0� ° ° �- - -� - -I I I I � ° � I I- _ ' ° (�' °`� � � c�5 a� `�_
<br /> � �
<br /> I � NEW DISHWASHER- � ' ' � I � � � � - � Q� j �
<br /> � � _ ' _ _ _ _ _ _ _ _ _ _ _ _ _ _ E2 �_- TYPICAL 4 LOCATIONS � � I I 1+4-1.2 , � � W A+
<br /> � � � BUILDINGTYPE1 � i � _ - _ - _ _ _ _ _ -_ - _ - _ � (�$ � W
<br /> O- , -� , � i i _
<br /> N I NEW SINK, FOOD CO IBM NA IT ON � �, i � , � _ _ �REPLACE EXISTING DOOR � � L-- � .�
<br /> I I WASTE DiSPOSER,- - - ' " ' � ' - -WASHER AND VENTLESS i WITH NEW LOUVERED DOOR- (�
<br /> AND FAUCET- LIVWG CONDENSING DRYER� I ( UTILITY I TYPICAL 2 LOCATIONS I � � � � •
<br /> - I � • � i � � BUILDING TYPE 1 � ++
<br /> TYPICAL4LOCATIONS TYPICAL4LOCATIONS i I I UNIT 3 C� � �
<br /> `;' ' BUILDING TYPE 1 UNIT 1 gUILDING TYPE 1 I �
<br /> I � I I I
<br /> `s' , � 3BD/1 BA i 1+4-1.1 � � � 1+4-3.1 1+4-32 i LIVING 1 BD/1 BA ' � � � -,
<br /> N � }+
<br /> I � NEW CONTINUOUS � DOOR WITH NEW G i - - -- _ ' _ - _ _ _ .- 1+4-001 � I � � � T
<br /> iRIDGE VENT(TYPICAL) I UNIT 2 LOUVERED DOOR- � � � ( W�� I UNIT 4 � � � � T�
<br /> - � - - - - - - - - - - - - - - - - - - - - - n I 3BD/1BA BUPLDNGTOEA110NS I � ( I 1BD/1BA I � .� o �
<br /> � I � � � N N
<br /> � � - I NEW ELECTRIC HEATER i ( I (
<br /> I
<br /> � � AND T-STATS-SEE � � WH �+4 3 7 I �
<br /> M I ` O I I
<br /> � �, ,�-Yf�r�Y � ELECTRICAL(TYPICAL)
<br /> I � INSTALL NEW � �� �
<br /> PHALT SHINGLE � �� � _ - _ _ - _ - _ _ _ _ _ - _ _ - .
<br /> R00
<br /> I � � � � Job No: 1662 Date:Apr 28 2017
<br /> � I � � I ' - - - - - - - - - - - " - ' - I / File No: 1662 Wiggums Renovation.rvt
<br /> 0 3 ` ' s o � _ e o � m � .� � � � � � o � � � o � � � m .o. � � v � � � ��� �. .�. - - - - - � �'� Drawn By: AMC
<br /> N I _ � � NEW WH ACCESS DOOR- I Checked By: NCM
<br /> - TYPICAL 2 LOCATIONS Issued for: Permit Submittal
<br /> o �`�'�"�r�r�v��,� I _ 3'-0"MIN. 1 BUILDING TYPE 1 I
<br /> I N TYPICAL BUILDING AND UNIT PLAN PROJECT NOTES 'I�� EZ , � Bid Set May 19 2017
<br /> TYPICAL A601
<br /> I � I - NOTES ON DRAWING ABOVE APPLY TO THE SPECIFIC UNITS SHOWN. �RUBBER _� 20'-0" 4'-7" 6'-6" 4'-7" 18'-8" � 2 Bid Addentla June 19 2017
<br /> - DEMOLISH ALL CASEWORK W KITCHENS AND BATHROOMS IN PREPARATION BASE � r����-� INSTALL NEW EXHAUST FAN 3 Permit Resubmittal July 12 2017
<br /> I OF WSTALLATION OF NEW WORK.TYPICAL AT ALL UNITS. ' �� � � \ IN NEW LAUNDRY CLOSET- I
<br /> � - REMOVE EXISTWG WOOD BASE TRIM THRU-OUT ALL UNITS E LA E TH RUBBER BASE. ROUTE WHOLE HOUSE FAN IN NEW SOF�� �VENTLESS � TYPICAL 4 LOCATIONS �
<br /> � 3 � I � �� T - REPAIR AND REPAINT ENTIRE UNIT INCLUDWG WALLS,CEILINGS,WINDOW, � SEE MECHANICAL DRAWWGS FOR ROUTE- CONDENSING � _ A401
<br /> 1 A30 BUILDING TYPE 1 I
<br /> AND DOOR TRIM AT SELECT LOCATIONS IDENTIFIED BY OWNER. TYPICAL 2 LOCATIONS BUILDING TYPE 1 DRYER � 3
<br /> - REPLACE WINDOW BLINDS THRUOUT ENTIRE UNIT. 1� �'�`J`'�-'�`J`�J�� A401
<br /> I - REPLACE EXISTING INTERIOR DOORS AND HARDWARE PER DOOR SCHEDULE. I ������,� �� I '
<br /> - REPLACE EXISTING ENTRY DOORS AND HARDWARE PER DOOR SCHEDULE. r�..,,�,-, Q THRU-WALL VENT CAP FOR WHOLE
<br /> I f�\� r-rl-rY r-��-
<br /> - REPAIR EXISTING FLOOR UNDERLAYMENT AT SELECT LOCATIONS IDENTIFIED BY OWNER. CRAWL SPACE NOTES: �-�r.� HOUSE FAN AT ALL UNITS-TYPICAL FLOOR AN D R00 F
<br /> � SEE G001 FOR ORIENTATION ON SITE INSTALL NEW VINYL PLANK FLOORING THRUOUT ENTIRE UNIT. ( ,-�r
<br /> - REPLACE EXISTING EXTERIOR AND INTERIOR LIGHT FIXTURES WITH NEW ENERGY STAR ' 4 LOCATIONS B ILDING TYPE 1 \�VENTLESS
<br /> -CONTRACTOR�f0 VERIFY ROOF CONFORMS TO RATED FIXTURES THRUOUT ENTIRE UNITS AND BUILDINGS. �1.REMOVE WATERAND CLEAN CRAWL SPACE, CONDENSING PLANS
<br /> CURRENT CODE REQUIREMENTS FOR VENTILATION. - REPLACE ALL EXISTING GUTTERS AND DOWNSPOUTS AND RE-ESTABLISH TIGHTLINE TREAT SOIL PER SPECIFICATION DRYER
<br /> CONNECTION TO EXISTING STORM DRAIN AT ALL DOWNSPOUTS WHERE OCCURS 2.INSTALL NEW VAPOR BARRIER PER NOTE: - GROUND FLOOR UNITS ARE ODD-NUMBERED
<br /> UPGRADE VENTILATION TO CURRENT CODE IF REQUIRED �-_�� � SPECIFICATION THRU-OUT CRAWL SPACE
<br /> ( - DEMO EXISTING ASPHALT SHINGLE ROOFING TO EXISTING - REMovE sixTY ExisriN�Foo�wasrE�isPosERs wHERE occuRs-iNSTa��NEw Foo� - UPPER FLOOR UNITS ARE EVEN-NUMBERED
<br /> ROOF 3.INSTALL NEW FLOOR INSULATION PER
<br /> '� WASTE DISPOSERS AT ALL NEW KITCHEN SINKS(80 LOCATIONS) SPEC�FICATION THR-OUT CRAWL SPACE GROUND FLOOR PLAN SHOWN - UPPER FLOOR PLAN SIMILAR
<br /> SHEATHING. ( UP TO TWO LAYERS OF EXISTING ROOFING. °EMo -`-`��
<br /> PROVIDE UNIT PRICE FOR ANY ADDITIONAL LAYERS DISCOVERED) � SEE G001 FOR ORIENTATION ON SITE
<br /> -���-J`�`�.�J'��_� J
<br /> . � Roof Plan - 2721 12th Street � Ground Floor Plan - 2721 12th Street _ .
<br /> 2 � 1/4" = 1'-0,� ,� 4�
<br /> . 1/8" = 1'-0" �,� 4� ,6�
<br /> 0 2' 8'
<br /> � 2� 8�
<br />
|