My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
824 W CASINO RD BASE FILE 2018-12-27
>
Address Records
>
W CASINO RD
>
824
>
BASE FILE
>
824 W CASINO RD BASE FILE 2018-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2018 1:45:44 PM
Creation date
12/27/2018 1:45:37 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
824
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• . • <br /> Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Avaire Apartments Renovation Date 2/13/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method on plans <br /> Yes C405.2 E2.0 <br /> general for spaces and lighting zone(s)served,or exception taken <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of <br /> NA C405.2 lighting controls C405.2 lighting controls;provide description of control <br /> (LLLC) capabilities and performance parameters <br /> For permanently installed lighting fixtures in dwelling units, <br /> NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and <br /> units lighting zone(s)served,or demonstrate compliance with high <br /> efficacy exception <br /> C405.2.3 <br /> C405.2.1.1 Indicate on plans the method of manual lighting control(whethei <br /> combined with occupancy sensor,automatic light reduction, <br /> Yes C405.2.2.2 Manual controls E2.0 <br /> C405.2.4 daylight responsive or specific application controls),location of <br /> C405:2:5 manual control device and area or specifice application it serves <br /> C405.2.2.1 Manual interior Indicate on plans which method of manual 50%lighting load <br /> NA C405.2.2.2reduction is provided,or whether lighting load is reduced via <br /> lighting controls <br /> C405.2.3 occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control <br /> during unoccupied periods(occupancy sensor or time switch) <br /> NA C405.2.2 Method of automatic for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which <br /> time switch control exception applies <br /> Indicate on plans the spaces served by occupancy sensors; <br /> NA C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to <br /> C405.2.1.1 controls be manual-on,automatic 50%-on,or serve a space eligible for <br /> automatic 100%-on per exception <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting <br /> warehouses power by 50% <br /> Indicate required digital timer switch control function when <br /> NA C405.2.6 Digital timer switch <br /> control is used <br /> NA C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting <br /> switch controls zone(s)served,include area sq.ft. <br /> • Indicate primary and secondary sidelight daylight zone areas on <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- <br /> Indicate toplight daylight zone areas on plans,include sq.ft; <br /> NA C405.2.4.3 Sidelight and toplight For small vertical fenestration assemblies(rough opening less <br /> than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area <br /> to daylight zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive <br /> controls; _ <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s) <br /> NA C405 24 Daylight responsive that apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least <br /> two even steps between 0%-100%of rated power; <br /> . <br /> , <br /> ---- <br /> Indicate that daylight sensing controls are configured to <br /> completely shut off all controlled lights in the lighting zone <br /> Additional controls- <br /> Identify spaces and lighting fixtures on plans that require <br /> NA C405.2.5 Specific application <br /> specific application lighting controls per this section <br /> lighting controls <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent <br /> case lighting are controlled independently from both general <br /> NA Items 1&2 lighting area lighting and other lighting applications within the same <br /> space; <br /> ....._ -------- ----- <br /> Indicate manual and automatic lighting control method <br /> • ; -.-,` <br /> • ...., <br /> ,, ,,, <br />
The URL can be used to link to this page
Your browser does not support the video tag.