Laserfiche WebLink
ii. Alternatively, a Snohomish County certified recorded Sales Prohibition <br /> Covenant can be submitted for the multi-family buildings which have <br /> building enclosure revisions. <br /> 3. Please identify how and where the costs for providing accessible improvements meet the <br /> requirements for (not to exceed) 20% of the cost of the alterations to the primary <br /> function areas, per IEBC section 506, and section 410.7 exception 1. Please note that <br /> any new work proposed on the drawings is already required to meet current accessibility <br /> requirements, so this would require additional 20% accessibility compliance over the <br /> cost of the work to convert the laundry areas to a second bedroom. <br /> Occupancy <br /> 1. Please indicate the occupant load of the new lease office and maintenance building, <br /> based on the assigned occupancy types and area of those occupancies. <br /> v"2. Two exits from the public space should be shown on the drawings for an assembly use, <br /> or the posted occupant load should be reduced to 49 maximum for a B occupancy, per <br /> IBC section 3011.2. <br /> .13. Is the proposed occupancy A-3 or B? Please indicate furniture for the proposed use. If <br /> it is tables and chairs, it may meet the requirement of a B occupancy with a maximum <br /> of 49 people with one exit. <br /> /4. The drawings should indicate specific signage at the main entrance door that the door <br /> will be open during business hours, per IBC section 1010.1.9.3, item 2.2. <br /> a. The door schedule should indicate that any locking devices on these doors are <br /> readily distinguishable as being locked. <br /> Construction <br /> 1. The removal of parking canopies and supporting structure should be shown in plan and <br /> section with the replacement proposed. <br /> Accessibility <br /> 1. For clarity in code requirements, please label the unit designations as some other <br /> reference than Type A and Type B units, because this is a reserved word for code <br /> requirements for compliance in residential units. The historically accessible units should <br /> have been designed to meet Type A requirements as a minimum. No Type B units were <br /> required at the time of original permitting, or under the scope of this permit. <br /> a. Five historically accessible units are required in the development, per the original <br /> site plan, per the attached Washington State Building Code Advisory Council <br /> Regulations for Barrier Free Facilities issued October 1, 1976, and amended in <br /> 1977 and 1979. <br /> b. Please identify those five apartments on the plans, and identify how the new <br /> change of use from a central laundry to a second bedroom meets either current <br /> or historical code requirements. Please be specific on the plans and details to <br /> show compliance. <br /> c. At least 2% of the parking provided for residents should be accessible parking, <br /> per IBC section 1106.2, item 1. This is in addition to the new van accessible <br /> parking provided for the clubhouse. <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br /> c°\\\ <br /> website: www.everettwa.gov/permit January 24, 2017 email: everettepsa@everettwa.gov °" r <br />