d L <br /> d. The location of the accessible parking should continue to be on the shortest <br /> route to the primary use and accessible building entrance, per IBC section <br /> 1106.6 and IEBC Section 1105.1. Accessible parking spaces should be shown in <br /> proximity to the historically accessible apartments as was required at the time of <br /> the 1980 permitting. Please indicate conforming curb cuts and accessible door <br /> hardware on the drawings. <br /> e. Please locate and dimension the historically accessible apartment accessible <br /> aisles and stalls on the site plan, adjacent to the five Type B units, per ICC/ANSI <br /> A117.1-2009 section 502.2. <br /> f. Accessible parking signage should indicate compliance with height and content of <br /> signage per ICC/ANSI A117.1-2009 section 502.7. <br /> 2. Additional accessible improvements to the primary function areas should be identified on <br /> the plans and the response letter, per IEBC section <br /> Energy <br /> 1. For the change of occupancy to the IBC Type A units and building enclosure revisions to <br /> the residential buildings, please indicate the prescriptive (or alternative) method of <br /> building envelope compliance on the cover sheet, to include detailed R or U-Values of <br /> modified exterior walls, doors, windows, roof-ceiling cavities, and new roofing, per <br /> WSEC Table R303.1.3(1) for glazed fenestration, WSEC Table R303.1.3(2) for doors, and <br /> WSEC Table R402.1.1 for building envelope and fenestration compliance. <br /> a. Printed reports demonstrating compliance with the building envelope should be <br /> submitted from the WSU website: <br /> http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode.aspx#EnergyCodeWo <br /> rksheets <br /> b. Please submit compliance using the alterations worksheet. <br /> c. Please submit compliance with the glazing schedule. <br /> d. Please submit compliance with the energy credit options. <br /> e. Please submit compliance with the heating system sizing worksheet for the IBC <br /> Type A unit expansions. <br /> 2. For the change of occupancy to the garage to make it a leasing office , please indicate <br /> the prescriptive (or alternative) method of building envelope compliance on the cover <br /> sheet, to include detailed R or U-Values of modified exterior walls, doors, windows, roof- <br /> ceiling cavities, and new roofing, per WSEC Table C402.4 for fenestration, and WSEC <br /> Table C402.1.3 for building envelope compliance. <br /> a. Roof replacements should be shown to meet minimum prescriptive requirements, <br /> per WSEC section C503.3.1. <br /> b. Printed reports demonstrating compliance with the building envelope, lighting, <br /> and mechanical should be submitted from the NEEC website: <br /> http://neec.net/energy-codes <br /> 3. For the new leasing office, please include actual code section language on the building <br /> drawings submitted for permit to identify required exterior lighting compliance, daylight <br /> compliance and interior lighting controls, sensors, and all other methods of compliance <br /> covered in electrical power and lighting systems per WSEC section C405. <br /> All codes cited refer to the 2015 International Building Code (IBC), the 2015 International <br /> Existing Building Code (IEBC), the 2015 International Property Maintenance Code (IPMC), the <br /> 2015 International Fire Code (IFC), the 2015 International Mechanical Code (IMC), and the <br /> 2015 Washington State Energy Code (WSEC), as amended by the State of Washington and <br /> adopted by the City of Everett. The current IBC referenced standard for accessible design is <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br /> website: www.everettwa.qov/permit January 24, 2017 email: everetteps(aeverettwa.gov <br />