My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
824 W CASINO RD BASE FILE 2018-12-27
>
Address Records
>
W CASINO RD
>
824
>
BASE FILE
>
824 W CASINO RD BASE FILE 2018-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2018 1:45:44 PM
Creation date
12/27/2018 1:45:37 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
824
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> Building Permit Plans Checklist, pg. 2 ENV-CHK <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 <br /> Project Title: Avaire Apartments Renovation Date 03/30/2017 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> 0103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll- <br /> yes Opaque doors up/sliding)on wall sections or in door schedules-applies to doors with <br /> 0402.4.4 less than 50%glazed area A6.1 <br /> No Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> No C402.2.5 unconditioned space Indicate framing material on floor sections; <br /> No insulation Indicate material density category and weight of qualifying mass floors <br /> no Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> C402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required <br /> no C303.2.1 insulation distance from top of slab; <br /> no Indicate method of protection of exposed exterior slab edge insulation <br /> No Indicate R-value of continuous insulation on wall section or foundation <br /> Radiantly heated detail; <br /> C402.2.6 slab-on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> No C303.2.1 insulation horizontally under the entire slab; <br /> No Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> No C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> C402.4.1 Provide calculation for total vertical fenestration area as a percentage of <br /> Vertical fenestration <br /> yes 0502.2.1 maximum area gross above grade wall area(WWR)for new construction,additions and <br /> 0503.3.2 alterations In ENV-SUM ENV-SUM <br /> Provide calculations showing that the percentage of overall conditioned <br /> No" floor area within daylight zones is equal to or greater than 50%in 1&2 <br /> story builidngs:OR <br /> Provide calculations showing that the percentage of overall net floor area <br /> Increased within daylight zones is equal to or greater than 25%in buildings 3 stories <br /> No C402.4.1.1 prescriptive or more;include the gross floor area and list of spaces omitted for the net <br /> 0405.2.4.1 maximum vertical floor area; <br /> 0502.2.1 fenestration area <br /> C503.3.2 with daylight zones Note in envelope plans that all lighting fixtures located within daylight <br /> and controls zones shall be provided with daylight responsive controls per WSEC <br /> No Section 0405.2.4.1;indicate method of control in lighting fixture schedules <br /> No Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> increasea Indicate high performance U-factors and SHGC values in fenestration <br /> No prescriptive <br /> 0402.4.1.3 schedules; <br /> maximum vertical <br /> C502.2.1 fenestration area If applicable,provide area-weighted U-factor used for <br /> No 0503.3.2 with high- multiple fenestration elements within the same fenestration category per <br /> nerfnrmanna nla7inn Table 0402.3 <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served <br /> No C402.4.1.4 maximum vertical by a dedicated outside air system(DOAS)that delivers ventilation air <br /> C403.6 fenestration area without requiring operation of the heating/cooling system per Section <br /> with DOAS C403.6 <br /> mechanical systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be <br /> No 0402.1.5 fenestration target used to account for vertical fenestration area in excess of the prescriptive <br /> area adjustment maximum allowed <br /> C402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof <br /> No 0502.2.2 <br /> 0503.3.3 area area(SRR)for new construction,additions and alterations in ENV-SUM <br /> Roof/skylight target Indicate if component performance with target area adjustment will be <br /> No 0402.1.5.2 used to account for skylight area in excess of the prescriptive maximum <br /> area adjustment allowed <br /> no Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC If applicable,provide area-weighted U-factor calculation(s)used for <br /> No C402.4.3 and VT for all multiple fenestration elements within the same fenestration category per <br /> 0303.1.3 fenestration Table C402.3 <br /> assemblies Indicate if values are NFRC or default;if default then specify frame type, <br /> yes glazing layers,gap width,low-e coatings,gas-fill A6.1 <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> No C402.4.3 devices provide projection factor calculations(Equation C4-6)and associated <br /> minimum SHGC for north and non-north orientations <br /> #/1))) <br />
The URL can be used to link to this page
Your browser does not support the video tag.