My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7533 LOWER RIDGE RD 2019-01-18
>
Address Records
>
LOWER RIDGE RD
>
7533
>
7533 LOWER RIDGE RD 2019-01-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2019 9:58:37 AM
Creation date
1/18/2019 9:58:29 AM
Metadata
Fields
Template:
Address Document
Street Name
LOWER RIDGE RD
Street Number
7533
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
inh 1915 Madison Street <br /> b ' Everett, Washington 98203 <br /> Phone: (425) 353-0531 <br /> Fax: (425) 353-6086 <br /> (.'i MPLETE HOME,<::BUILDING PLAN CENTER www.designlines.com <br /> March 25, 2011 <br /> Jeff Heilman <br /> Development Technician <br /> City of Everett <br /> Subject:Chun-Sheng Wang <br /> 7533 Lower Ridge Rd. <br /> Plan Check No. CW1101-001,27 Jan 2011 <br /> Greetings, <br /> In response to your plan check letter corrections and additions have been made to plan sheets as follows: <br /> 1. Energy code compliance is shown by the component performance method. Worksheets have been <br /> modified to reflect the actual square footage and all components and areas have been rechecked to reflect <br /> reality. <br /> 2. Per structural engineer. <br /> 3. Garage/basement section added to sheet 3,showing all components involved. <br /> 4. Appliances are shown on floor plan,sheet 2.Addition is not to be a"second kitchen". <br /> 5. Per client's conversation with City,interior stair not required. <br /> 6. "New Dwelling"reference removed from sheet 1.No other reference found. <br /> 7. Note added to foundation plan,sheet 2,showing calculations for required venting. Existing vents shown on <br /> foundation plan. One additional vent will need to be installed preferably above one of the existing vents to <br /> limit the impact on lateral bracing. <br /> 8. Client to fix site plan. <br /> In addition to these corrections the square footage noted on the plans has been changed on sheet 2 to reflect the <br /> actual area of the new basement.Two new sets of the revised plans will be provided for plan checking. Feel free to <br /> contact Design Lines if there are any further questions or concems. <br /> Sincerely, <br /> DexterTaylor <br /> dexter@ designlines.com <br /> MAR 2 ?On <br />
The URL can be used to link to this page
Your browser does not support the video tag.