° SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: CROSSDOCK FACILITY Date 12/29/2016 <br /> 6.3� Max.Target: 30% For Building Department Use <br /> Fenestration Area as%gross above-grade wall area g <br /> Skylight Area as%gross roof area Max.Target: 3% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the. <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. • <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x f SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> Skylight Totals <br /> • <br /> All Non-North Vertical Fenestration+ • Proposed SHGC Target SHGC++ <br /> PF <br /> • Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A) SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Vestibule 112-Door A-1,Storefront W31A3.01.Refer to <br /> W3/A3.01 Sunscreen detail on 6/A2.01 for Projection Factor 0.13 0.40 252 101 PF<0.2 0.40 252 100.8 <br /> 0.2.5PF<0.E 0.48 <br /> PF.. 0.5 0.69 <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals i 252.0 100.8 252.0 100.8 <br /> must be entered in the correct table according to I_ <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> INorth Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> PF<0.2 0.53 <br /> 0.25PF<0.5 0.58 <br /> PF 0.5 0.69 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design,Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x rea SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 252.0 I 100.8 Al, 252.0 100.8 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br />
The URL can be used to link to this page
Your browser does not support the video tag.