Laserfiche WebLink
• <br /> , <br /> F 4 Building Permit Plans Checklist, pg. 2 ENV-CHK • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all Ri <br /> Project Title: cRossoocK FACILITY Date 12/29/2016 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> 0103.2 Indicate rated U-factor(swinging)or R-value(non-swinging-roll- <br /> yes 0402.4.4 Opaque doors up/sliding)on wall sections or in door schedules-applies to doors with Al.11,A3.00, <br /> less than 50%glazed area A3.01 <br /> Floor over outdoor or Indicate R-value(s)of cavity/continuous insulation on floor sections; <br /> na C402.2.5 unconditioned space Indicate framing material on floor sections; <br /> insulation Indicate material density category and weight of qualifying mass floors <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> detail; <br /> yes 0402.2.6 Slab-on-grade floor Indicate insulation extends down vertically and/or horizontally the required <br /> 0303.2.1 insulation distance from top of slab; <br /> Indicate method of protection of exposed exterior slab edge insulation A3.16,Spec's . <br /> Indicate R-value of continuous insulation on wall section or foundation <br /> Radiantly heated detail; <br /> na 0402.2.6 slab-on-grade floor Indicate insulation extends down vertically from top of slab and then <br /> 0303.2.1 insulation horizontally under the entire slab; <br /> Indicate method of protection of exposed exterior slab edge insulation <br /> Radiant heating Indicate insulation R-value behind radiant panels,U-bend/headers and <br /> na C402.2.8 system insulation bottom surface of radiantly heated floors(other than radiantly heated slab- <br /> on-grade) <br /> 0402.4.1 Vertical fenestration Provide calculation for total vertical fenestration area as a percentage of <br /> yes 0502.2.1 gross above grade wall area(WWR)for new construction,additions and A2.01,A3.00, <br /> 0503.3.2 maximum area alterations In ENV-SUM A3.01 <br /> • Provide calculations showing that the percentage of overall conditioned <br /> floor area within daylight zones is equal to or greater than 50%in 1 &2 <br /> story builidngs:OR <br /> Provide calculations showing that the percentage of overall net floor area <br /> Increased within daylight zones is equal to or greater than 25%in buildings 3 stories <br /> 0402.4.1.1 prescriptive or more;include the gross floor area and list of spaces omitted for the net <br /> na 0405.2.4.1 maximum vertical floor area; <br /> 0502.2.1 fenestration area Note in envelope plans that all lighting fixtures located within daylight <br /> 0503.3.2 with daylight zones zones shall be provided with daylight responsive controls per WSEC <br /> and controls <br /> Section C405.2.4.1;indicate method of control in lighting fixture schedules <br /> Indicate that the VT of vertical fenestration is at least 1.1 times the rated <br /> SHGC <br /> Increased Indicate high performance U-factors and SHGC values in fenestration <br /> 0402.4.1.3 prescriptive schedules; <br /> na 0502.2.1 maximum vertical If applicable,provide area-weighted U-factor calculation(s)used for <br /> C503.3.2 fenestration area multiple fenestration elements within the same fenestration category per <br /> with high- Table C402.3 <br /> nerfnrmanna nla7inn <br /> Increased <br /> prescriptive Indicate that for eligibility,all occupied,conditioned spaces will be served <br /> C402.4.1.4 maximum vertical by a dedicated outside air system(DOAS)that delivers ventilation air <br /> na C403.6 fenestration area without requiring operation of the heating/cooling system per Section <br /> with DOAS 0403.6 <br /> mechanical systems <br /> Wall/vertical Indicate if component performance with target area adjustment will be <br /> na 0402.1.5 fenestration target used to account for vertical fenestration area in excess of the prescriptive <br /> area adjustment maximum allowed <br /> • <br /> 0402.4.1 Skylight maximum Provide calculation for total skylight area as a percentage of gross roof <br /> na 0502.2.2 area area(SRR)for new construction,additions and alterations in ENV-SUM <br /> 0503.3.3 <br /> Roof/skylight target Indicate if component performance with target area adjustment will be <br /> na 0402.1.5.2 used to account for skylight area in excess of the prescriptive maximum <br /> area adjustment allowed • <br /> Indicate U-factors,SHGC and VT values in fenestration schedules; <br /> U-factors,SHGC If applicable,provide area-weighted U-factor calculation(s)used for <br /> 0402.4.3 and VT for all multiple fenestration elements within the same fenestration category per <br /> yes 0303.1.3 fenestration <br /> Table 0402.3 <br /> assemblies Indicate if values are NFRC or default;if default then specify frame type, <br /> glazing layers,gap width;low-e coatings,gas-fill Spec's <br /> Permanent shading For windows with overhangs or permanent projection shading devices, <br /> yes C402.4.3 provide projection factor calculations(Equation C4-6)and associated <br /> devices minimum SHGC for north and non-north orientations 6/A2.01 <br />