My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4110 CLIFF DR 2019-01-25
>
Address Records
>
CLIFF DR
>
4110
>
4110 CLIFF DR 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 2:35:49 PM
Creation date
1/25/2019 2:35:39 PM
Metadata
Fields
Template:
Address Document
Street Name
CLIFF DR
Street Number
4110
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t(30(t7 <br /> PUBLIC WORKS <br /> FILE COPY <br /> Owner: FFCC 01 LLC <br /> Job Address: 4110 Cliff Drive <br /> Plan Check No: CW1612-003 <br /> RE: Remodel of Single Family Residence <br /> Dear Mr. Smith, <br /> In response to the application for a.building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> In order for the processing of your application to continue,it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> General <br /> 1. The building was in the process of a substantial remodel without required permits when <br /> the stop work order was issued. The plans show many walls as'existing'that are new or <br /> substantially altered. R106.1.1 <br /> 2. Work begun without required. permits includes electrical, plumbing and building <br /> modifications — much of which has been covered by wallboard. In order for <br /> inspections/approvals to occur, wallboard will need to be removed to expose all wiring, <br /> plumbing and framing that has not been previously inspected and approved. R109.4 <br /> 3. Snohomish County records list the structure as having 1 and 1/2 baths. The structure <br /> now has 3 1/2 baths. The permit will be revised to include the additional plumbing <br /> fixtures. All fixtures will be inspected and approval will be required. R105.1 <br /> 4. The heat pump has no permit record. The location of the pump should be shown on the <br /> site plan and is subject to Land Use approval. The permit will include inspection and <br /> approval of the pump. R105.1 <br /> 5. The existing interior and exterior walls along building lines C, D & 3 appear to have <br /> been altered significantly/completely or removed. As the bracing system has been <br /> altered/removed along those lines, the lateral design should be shown to comply with <br /> the current code requirements of the IRC. <br /> 6. The plans should show the locations of required smoke alarms and that they will be <br /> hardwired, interconnected and provided with battery backup. R314 <br /> 7. The plans should show the locations of required carbon monoxide alarms and that they <br /> will be hardwired with battery backup. R315 <br />
The URL can be used to link to this page
Your browser does not support the video tag.