Laserfiche WebLink
8. The size and location of each required shower/bathroom, and kitchen exhaust fan <br /> should be shown on the plans. Table M1507.4 <br /> 9. The distance from the centerline of the toilets to any obstruction (wall or otherwise) <br /> should be shown to be a minimum of 15 inches. R307.1 <br /> 10.The rise and run of the stairs should be shown on the plans. R311.7.5 &IFC 1104.10 <br /> 11.A handrail should be shown on the stairway. R311.7.7 <br /> 12.A closet has been framed in around the electrical panel in the closet (a violation of the <br /> National Electrical Code) of Master bedroom #2. The plans show that the enclosure will <br /> be removed. The location of the new closet should be shown on the plans. <br /> 13.All sleeping room emergency egress openings (with requirements) should be shown on <br /> the plans. R310 <br /> Washington State Energy Code <br /> 1. R-21 insulation should be shown in all exterior walls (2x6) that have had the framing <br /> exposed. R503.1.1 <br /> 2. The fenestration U-factors should be specified on the plans per Table R402.1.1 <br /> (maximum of 0.30). <br /> All codes cited refer to the 2015 International Residential Code (IRC), and the 2015 Washington <br /> State Energy Code (WSEC), as amended by the State of Washington and adopted by the City of <br /> Everett. These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Traffic, Planning or Fire). All required <br /> submittals must be of sufficient detail and information to ensure that the proposed structure <br /> will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Tony Lee <br /> Building Official <br /> (c:91/) <br /> c ,) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425)257-8813 • Page 2 <br />