My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1602 COLBY AVE 2019-01-25
>
Address Records
>
COLBY AVE
>
1602
>
1602 COLBY AVE 2019-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2019 3:35:01 PM
Creation date
1/25/2019 3:34:56 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1602
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> Item #4. Office space must be a minum 70 square feet, and no <br /> OK' v horizontal dimension less that 7'. <br /> Response: Changed wall location over the stairs to basement, thus <br /> getting the width stipulated here. See the sheet Al. <br /> Item #5. ,/1 igid insulation was shown on exterior of the foundation on <br /> detail #2 of Detail DT1.0. <br /> Response: The detail was originally drawn incorrectly. It has been <br /> changed to show insulation at the interior at the furred <br /> walls, minimum R-19 called out. , -2./ W iy j PLO <br /> Item #6. Fireblocking required to cut off all concealed draft <br /> 5 openings. <br /> �"� "4 esponse: Added call out for fire blocking at walls to second floor <br /> framing connection. Modified all sections accordingly. <br /> Item #7. /The vaulted ceilings are required to have R-38 insulation <br /> with 1" air space. <br /> Response: Using blown in rigid closed cell foam insulation that <br /> provides over R38 value and eliminates the need for <br /> venting. See sections for callouts. <br /> Item # 8. / how 1" clear space for ventilation and insulation in the <br /> I� section of the plan set. <br /> Response: The revised sections now shows the rigid closed cell foam <br /> insulation and no air gap required in this system. <br /> Item #9. ,,/Provide roof ventilation calculations, and show size and <br /> location of vents. 4,,,, 4.fitc,474Oe4 c f I '/W✓ <br /> ec4444416 aResponse: All new construction on the second floorof ha blown in <br /> closed cell foam insulation and therefore do not required <br /> any ventilation elements. <br /> Item#10. The exterior elevations do not match the floor plans. <br /> Response: Added, moved or changed sizes on the exterior elevations to <br /> coordinate accurately with the floor plans of the remodeled ;,r-, <br /> house. <br />
The URL can be used to link to this page
Your browser does not support the video tag.