My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8215 BROADWAY VERIZON ANTENNA 2021-02-18
>
Address Records
>
BROADWAY
>
8215
>
VERIZON ANTENNA
>
8215 BROADWAY VERIZON ANTENNA 2021-02-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 8:45:28 AM
Creation date
1/28/2019 8:02:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8215
Tenant Name
VERIZON ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS PND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> 01 APPROXIMATE LOCATION OF #2 AWG SOLID BARE TINNED GROUND RING. GROUND RING SHALL BE BURIED 30" - OMISSIONS.No VARIATIONS oR MODIFICATIONS To WORK <br /> SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN <br /> BELOW THE FROST LINE OR 30" BELOW GRADE, WHICHEVER IS GREATER. EXACT LOCATION AND NUMBER OF APPROVAL ALL PREVIOUS ISSUES Of THIS DRAWING ARE <br /> GROUND RODS TO BE DETERMINED ON SITE AND BASED ON "FALL OF POTENTIAL GROUND RESISTANCE METHOD" SUPERSEDED BY THE LATEST REVISION.ALL DRAWINGS AND <br /> FOR RESISTANCE < 5 OHMS. UNLESS OTHERWISE NOTED, DRIVEN GROUND RODS ARE TO BE BURIED AT 16 FEET HERSHFIELD NS REMNN THE EITHERRER M RISON ONRHERS <br /> INTERVALS. N NORORHERSHFIELD <br /> ARCHITECTR �WIILL BEPROVIDIINGR CONSTRUCTIONTO <br /> REVIEW OF THIS PROJECT. <br /> /1 <br /> O PROVIDE 3/4"x10'-O" LONG COPPER CLAD STEEL (COPPER WELD) GROUND ROD AS SHOWN. PROVIDE INSPECTION <br /> SLEEVE AT GROUND ROD TO SHOW BOND TO EXTERIOR BURIED GROUND RING (MINIMUM OF 4 INSPECTION <br /> SLEEVES/ SEE DETAIL 8/E-7). INSTALL GROUND ROD TWO (2) FEET MINIMUM AWAY FROM ANY SLAB. INSTALL SO 8259 <br /> THAT TOP OF GROUND ROD IS 30" BELOW GRADE OR FROST LINE, WHICHEVER IS DEEPER. EXACT LOCATION AND REGISTERED <br /> NUMBER OF GROUND RODS TO BE ESTABLISHED ON SITE AND BASED ON "FALL OF POTENTIAL GROUND <br /> RESISTANCE METHOD" FOR RESISTANCE < 5 OHMS. UNLESS OTHERWISE NOTED, DRIVEN GROUND RODS ARE ".CHITECT <br /> Jj BONDED TO THE BURIED GROUND RING AT 16 FEET INTERVALS. ' <br /> ONOT USED. r <br /> O4 NOT USED. El '•=E`_11E'R be 'A 1011° <br /> O #2 AWG GROUND FROM SERVICE ENTRANCE GROUND ELECTRODE TO EXTERNAL GROUND RING. . 1:54:1'-II J's!' <br /> O #2 AWG FROM H-FRAME TO EXTERNAL GROUND RING (TYP OF (2) PLACES). <br /> 0 #2 AWG GROUND FROM ICE BRIDGE VERTICAL POSTS TO EXTERNAL GROUND RING (TYPICAL). <br /> @ NOT USED. ROBERT JERRY LARA <br /> 0 NOT USED. LICENSED ARCHITECT <br /> STATE OF WASHINGTON <br /> 10 NOT USED. 8259 <br /> 11 EQUIPMENT GROUND RING AND TOWER GROUND RING SHALL BE BONDED TOGETHER IN AT LEAST TWO (2) POINTS <br /> USING A #2 AWG SOLID BARE TINNED COPPER CONDUCTOR. 00 CONSTRUCTION <br /> 12 BOND TO EQUIPMENT CABINET ENCLOSURE USING A MANUF. APPROVED CONNECTION WITH (2) # 2 AWG SOLID <br /> BARE TINNED COPPER CONDUCTORS AND EXOTHERMICALLY WELD TO GROUND RING. ®TYP <br /> 13 REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ANTENNA(S) AND ANTENNA - ' � <br /> SUPPORTS FRAME. Ili�Sw4n�' ,` :..,. 6TYP <br /> 14 EXTEND GROUNDING CONDUCTOR TO ANTENNA LOCATIONS AND BOND TO ANTENNA PIPE MOUNT. USE AN s��"r� 4 �, TYP <br /> EXOTHERMIC WELD AT ANTENNA PIPE MOUNT. SUPPORT CONDUCTOR AS REQUIRED EVERY TWO (2) FEET MINIMUM. •.'W G, w�`�p�•��.�`�, 0 09/14/17 ISSUED FOR PERMIT <br /> 15 PROVIDE #2 SOLID BARE TINNED COPPER CONDUCTOR FROM TEGB TO TOWER GROUND RING. TYPICAL OF TWO (2). G cy4'i:'�`e+��r I "` B 08/09/17 ISSUED FOR REVIEW <br /> 16 PROVIDE ANTENNA CABLE GROUND BAR. BOND ANTENNA CABLE GROUNDING KITS TO GROUND BAR. CONNECTION ;aVga017 <br /> ' '.`^O V2� "' � !�m rcs 0 A 07/27/17 ISSUED FOR REVIEW <br /> SHALL BE THE RESPONSIBILITY OF THE ANTENNA CABLE INSTALLER. BOND GROUND BAR TO TOWER USING ONE(1) �� doge <br /> #2 AWG SOLID TINNED COPPER CONDUCTOR. PROVIDE A U.L. LISTED CONNECTOR SUITABLE FOR THE MATERIALS A'_3e"`y °�'s <br /> a:C�` y,„„..„.. ^� �� / /1--- <br /> � No. Date Revision <br /> BEING CONNECTED. PROVIDE EXOTHERMIC WELDS FOR BONDS TO STEEL BEAM OR FRAME. .°'y ?'' �� A,yi�« y..u-wld-�i►•!�• / <br /> ` , �+' �v `A� Client: <br /> 17 THE TOWER EXIT GROUND BUS BAR TEGB SHALL BE INSTALLED BELOW THETRANSMISSION IN R N T • U <br /> O ( ) LNE ELLINE I GROUND KITS,. - t F,..��� 4,-x�G i � <br /> NEAR THE AREA A THE TOWER AT THE POINT WHERE THE ANTENNA TRANSMISSION LINES TRANSITION FROM THE ` - �p4t. i'''ll' . •4� \ TYP <br /> TOWER TO THE CABINETS. VERIFY EXACT LOCATION OF GROUNDING BAR FOR PROPER CONDUCTOR LENGTH. .7i.4 <br /> GROUNDING BAR PROVIDED BY THE ANTENNA CABLE INSTALLER. FINAL EXOTHERMIC WELD FROM THE BURIED <br /> 0 l • '� -�� ��` <br /> GROUNDING RING TO GROUND BAR SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. COORDINATE 1eltt i d .d'� ��� ._ \ <br /> WITH ANTENNA CABLE INSTALLER FOR SCHEDULE TO MAKE CONNECTION. PROVIDE 3/4" PVC SLEEVE WITH SWEEP ' <br /> ,ft <br /> BEND IN NEW ANTENNA BASE INSTALLATIONS FOR CONNECTION OF TEGB TO TOWER GROUND RING. 00III <br /> I <br /> " / � / �' '` * (�� © verizon <br /> ,�� 718 EXTEND GROUNDING CONDUCTORS TO REMAINING SECTOR ANTENNA PIPE MOUNT LOCATIONS AND BOND WITH j ,A 0/ / <br /> EXOTHERMIC WELDS TO ANTENNA PIPE MOUNT. SUPPORT CONDUCTOR AS REQUIRED EVERY TWO FEET MINIMUM. ® '" <br /> • 4 4•. <br /> 19 THE TOWER STRUCTURE STEEL SHALL BE UTILIZED FOR DISSIPATING THE LIGHTNING ENERGY. THE TOWER GROUND ' / ` / Implementation Teom: <br /> • <br /> BARS FOR ANTENNA GROUNDING SHALL BE.DIRECTLY FASTENED TO THE STEEL STRUCTURE WITH STAINLESS STEEL <br /> � / / <br /> HARDWARE &/OR ANGLE ADAPTORS (E.G. PIROD/VALMONT PART #167105 OR EQUIV. - W/O "CHERRY" 'O� / <br /> Wail.INSULATORS. THIS TYPE OF INSTALLATION SPECIFICALLY PRECLUDES THE USE OF INSULATORS BETWEEN THE TOWERs ,s.4, <br /> 1 • <br /> STRUCTURE & THE GROUND BARS & DOES NOT ALLOW ANY DRILLING OF WELDING TO THE TOWER. X4.1 0 4 , / '\ \'(\ / (.0r7----:.‘ CROv Y N <br /> 8 p / \ I\\ / CASTLE <br /> �: :Sys �� 1\\ \\` / .+ <br /> ;,r <br /> ��:'�O„" ��y / \ \\\\ `\\ .(� / / 1505 WESTLAKE AVE N,SUITE 800 <br /> �i�. Y <br /> �4i ___�\ ,\\ \1 SEATTLE,WA 98109 <br /> .`A. \ \\\ 1 >, / <br /> ice.>� n _ 1 <br /> t', ,`v d .. � � �� j 4/ A&E Team: <br /> ;111 m <br /> \N • Il/ <br /> / 11) s <br /> ' --/-'� MORRISON HERSHFIELD <br /> INSPECTION.WELL <br /> - /\ ---7,,.. 600 STEWART ST,SUITE 200 <br /> (//- SEATTLE,WA 98101 <br /> •-r <br /> i <br /> Tel:206.268.7370 <br /> �lrl O T - vhwv.monisonhershfield.com <br /> 0 1 / Project Info: <br /> // BU#824022 <br /> T\ FEELY <br /> `IF <br /> / © <br /> 8215 BROADWAY AVE <br /> EVERETi, WA 98203 <br /> Drawing Title: <br /> II <br /> GROUNDING PLAN <br /> AND NOTES <br /> Project Number: Start Date: <br /> 7170282 07/27/17 <br /> NOTE: Drafter: Designer: <br /> NO SOILS RESISTIVITY TESTING WAS PROVIDED AT THE TIME OF THIS DESIGN. JS LB <br /> Project Manager. Professional of Record: <br /> RKL RL <br /> Revision No: Sheet No: <br /> 0 <br /> 24-x36'SCALE: NOT TO SCALECALGROUNDING NOTES 2 24"x36"SCALE:CNOT TO SCALE <br /> CA E GROUNDING PLAN 1 E-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.