8215 BROADWAY VERIZON ANTENNA 2021-02-18
>
Address Records
>
BROADWAY
>
8215
>
VERIZON ANTENNA
>
8215 BROADWAY VERIZON ANTENNA 2021-02-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 8:45:28 AM
Creation date
1/28/2019 8:02:35 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
8215
Tenant Name
VERIZON ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POWER CABINET PANEL SCHEDULE (PANEL PP-1 ) DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS OR MODIFICATIONS.TO WORK <br /> SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN <br /> BUS VA BUS BUS VA APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> LOAD WIRE GND COND AMPS AMPS COND GND WIRE LOAD <br /> A - B A B A B_ SPECIFICATIONDED S REMAIN PROPERTY OF MORRISON <br /> THE LATEST REVISION.AU_DRAWINGS AND <br /> HERSHFIELD CORPORATION.NEITHER MORRISON HERSHFIELD <br /> 2792 - ANDREW PDU/BATT CABINET #6 #8 2" 40 1 2 60 1" #10 #6 SURGE ARRESTOR 0 NOR <br /> PVIEW THE ARCHITECT <br /> PROJECCT BE PROVIDING CONSTRUCTION <br /> t 2792 RECTIFIERS ** 3 4 0 <br /> 2792 ANDREW PDU/BATT CABINET #6 #8 2" 40 5 -•— 6 20 1/2" #12 #12 TELCO GFI RECEPTACLE 180 <br /> 8259 <br /> 2792 RECTIFIERS ** 7 —•- 8 20 1/2" #12 #12 TELCO CABINET FAN 180 <br /> ' R GISTERED <br /> j2792 -ANDREW PDU/BATT CABINET #6 #8 2" 40 9 S 10 20 1/2" #12 #12 EXTERIOR LIGHT 332 CHITECT <br /> 1 - 2792 RECTIFIERS ** 11 —0- 12 - - - - SPACE - <br /> 2792 _ ANDREW PDU/BATT CABINET #6 #8 2" 40 13 -0— 14 - - - - SPACE - of <br /> -_ 2792 RECTIFIERS ** 15 —� 16 SPACE - —_ 1�•1 ) <br /> '• •II S <br /> :- ±1--.-17=SPARE <br /> - 100 17 • 18 - - SPACE _ 1:54:08-1,I.,I <br /> ---_'.--- - 19 —0-20 - - - - SPACE - <br /> 180 RECEPTACLE INSIDE PDU CABINET** #10 #10 2" 20 21 22 - - - - SPACE - <br /> a 180 RECEPTACLE INSIDE BATTERY CABINET ** #10 #10 2" 20 23 —di-24 - - - - SPACE <br /> - SPACE - - - - 25 -0— ROBERT JERRY LARA <br /> —26 - - - - SPACE - <br /> LICENSED ARCHITECT <br /> 5 _ - SPACE - - - - 27 �28 - - - - SPACE - STATE OF WASHINGTON <br /> 24'x36-SCALE: NOT TO SCALE NOT USEDSPACE - - - - 29 -•—30 - - - - SPACE - 8259 <br /> 11"x17"SCALE: NOT TO SCALE <br /> - -' <br /> ---- SPACE - - - - 31 -�32 - - - - SPACE --- <br /> -- - - - - - - - _---- CONSTRUCTION <br /> — SPACE - 33 -�34 SPACE <br /> ----------------- - SPACE - - - - 35 • 36 - - - - SPACE _---------- <br /> - SPACE - - - - 37 �-38 - - - - SPACE - <br /> _ -= ---• <br /> _ - SPACE 39 <br /> - - - - -40 SPACE --- - <br /> SPACE 41 -111— - - - -42 SPACE 0 09/14/17 ISSUED FOR PERMIT <br /> TOTAL VA: BUS A 11860 BUS B 11528 CONNECTED VA:23388 AMPERES: BUS A 99 BUS B 96 TOTAL 97 - <br /> RATED VOLTAGE: III120/208 II 120/240 CI277/480 1 PHASE, 3 WIRE BRANCH POLES CI 12 1:118 CI20 CI24 CI30 El36 MI 42 B 08/09/17 ISSUED FOR REVIEW <br /> IRATED AMPS: ❑ 100 11 200 ❑ 400 CABINET: • SURFACE ❑ FLUSH A 07/27/17 ISSUED FOR REVIEW <br /> FULL NEUTRAL BUS • GROUND BUS II HINGED DOOR II KEYED DOOR LATCH ENCLOSURE TYPE NEMA-3R No. Date Revision <br /> BRANCH DEVICES ❑ FUSED 111 CIRCUIT BREAKER Client: <br /> MAIN LUGS ONLY MAIN 200A •BREAKER ❑ FUSED SWITCH <br /> ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT CURRENT OF MINIMUM 42,000 AMPS SYMMETRICAL. <br /> ACCEPTABLE MANUFACTURER/MODEL: INTERSECT MODEL: D300L verizon <br /> NOTES: <br /> PANEL PP-1 IS INCORPORATED INTO THE INTEGRATED LOAD CENTER (ILC). <br /> ALL BREAKER POSITIONS TO BE POPULATED AS SHOWN ABOVE INCLUSIVE CIRCUIT BREAKERS INTENDED FOR OPTIONAL EQUIPMENT. ALL UNUSED BREAKERS TO BE LABELED "SPARE" <br /> (*0) CIRCUITS ROUTED INSIDE SAME CONDUIT Implementation Team: <br /> 11N1 = NOT TO S NOT USED 4 11"x17"SCALE:CNOT TO SCAB PANEL SCHEDULE 3 r" CROWN <br /> CASTLE <br /> 1505 WESTLAKE AVE N,SUITE 800 <br /> SEATTLE,WA 98109 <br /> EXOTHERMIC WELD A&E Team: <br /> FINISHED GRADE <br /> m� <br /> '` ' MORRISON HERSHFIELD <br /> WAVE GUIDE POST ELEVATION - 600 STEWART ST,SUITE 200 <br /> BONDING CONDUCTOR DRILL WAVE GUIDE GRATING IF SEATTLE,WA 98101 <br /> TO EQUIPMENT PAD REQUIRED TO ALLOW INSTALLATION Tel 206268 7370 <br /> GROUND RING OF STAINLESS STEEL THREADED ROD www.mornsonhershfield.com <br /> WAVE GUIDE GRATING Project Info: <br /> FENDER WASHER TYP <br /> I i 1/4"STAINLESS STEEL / B 1# 824022 <br /> WAVE GUIDE POST THREADED ROD (TYPICAL EACH �, TOWARD L7ll V <br /> END OF GROUND BAR PLATE) i�- EQUIPMENT PAD FEELY <br /> ¢0 8215 BROADWAY AVE <br /> A _ EVERETT, WA 98203 <br /> 85 <br /> CC <br /> p _ Ii! <br /> ANTENNA CABLE z Drawing Title: <br /> 3 `'0ANTENNA CABLE GROUNDING CABLE <br /> FULL THREADED ROD �i (ACTUAL NUMBER r� AS REQUIRED) ELECTRICAL, <br /> CABLE SUPPORT � * WAVE GUIDE MOUNTED GROUNDING DETAILS & <br /> COPPER GROUND BAR PLATE <br /> NUT AND LOCK WASHER PANEL SCHEDULE <br /> WAVE GUIDE MOUNTED COMBINATION (TYPICAL) SECTION A-A <br /> GROUND BAR PLATE. 4-1 <br /> SUSPEND BELOW LOWEST GROUNDING CABLE <br /> W OF ANTENNA NOTE: SEE SHEET C-3 FOR CONSTRUCTION Project Number: Start Date: <br /> CABLEROS. LOCATE WITHIN (TYP. EACH SPECIFICATIONS FOR WAVEGUIDE SUPPORT 7170282 07/27/17 <br /> 2•-0"OF CLOSEST ICE ANTENNA CABLE) <br /> BRIDGING POST TO Drafter: Designer: <br /> ANTENNA CABLE COVER #2 AWG BARE TINNED SOLID <br /> ASSEMBLY COPPER PIGTAIL ROUTE PIGTAIL <br /> SUCH AS TO AVOID 90• BENDS PS <br /> BETWEEN GROUND BAR PLATE Project Manager. Professional of Record: <br /> AND WAVE GUIDE POST RKL RL <br /> Revision No: Sheet No: <br /> 0 E_5 <br /> WAVEGUIDE MOUNTED GROUND BAR PLATE INSTALLATION 2 NOT USED 1 , <br />