My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3601 COLBY AVE 2019-01-28
>
Address Records
>
COLBY AVE
>
3601
>
3601 COLBY AVE 2019-01-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2019 9:07:36 AM
Creation date
1/28/2019 9:07:33 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3601
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Ener ode Compliance Forms for Commercial,R2 and R3 ove odes and all R1-Page 2 of 7 <br /> • Mechanical Permit Plans Ch.;cklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Dr.Amy Norman Date 6/5/2018 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> C403.2.4.3 Stairway and shaft vent I Indicate location of stairway and shaft vent dampers on plans;verify dampers are Class 1 <br /> dampers motorized;refer to HVAC System Controls for additional requirements <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> C403.2.4.4 Zone isolation dampers are expected to be occupied non-simultaneously;identify isolation zone areas on plans and <br /> locations of associated isolation dampers in HVAC distribution system;refer to HVAC System <br /> Controls for additional requirements <br /> For cooling systems with humidification equipment that are also required to have air <br /> C403.2.3.4 Humidification economizer,indicate humidifier is adiabatic(direct evaporative or fog atomization),or <br /> exception taken <br /> Additional Efficiency Package Option,More Efficient HVAC Equipment&Fan Performance- <br /> Must comply with all 3 provisions to be eligible <br /> C406.2.1 To comply with additional efficiency package option,calculate the percentage of heating and <br /> C403.2.3 HVAC system selection cooling equipment in the project(based on output capacity)that do not have a corresponding <br /> WSEC listed efficiency;shall be less than 10%to comply <br /> C406.2.2 Minimum equipment To comply with additional efficiency package option,indicate that all listed heating and cooling <br /> C403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br /> C406.2.3 To comply with additional efficiency package option,indicate rated FEG of stand alone fans is <br /> C403.2.11.3 Minimum fan efficiency >_71;indicate these fans are sized so the fan efficiency at design conditions is within 10%of <br /> the maximum total or static efficiency <br /> HVAC System Controls <br /> Indicate locations of thermostatic and humidity control devices and the zones they serve on Existing <br /> plans,including perimeter system zones - location <br /> Where adjacent(neighboring)zones are controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or loss),and are connected by permanent <br /> Thermostatic controls openings>10%of either zone sf area,indicate controls configured to prevent adjacent zones <br /> Yes C403.2.4.1 (thermostats and from operating in conflicting modes(one in heat,other in cool);applies to adjacent perimeter <br /> humidistats) zones,adjacent nonperimeter zones,and adjacent perimeter and nonperimeter zones <br /> If applying Exception 2 to nonperimeter zones adjacent to perimeter zones,indicate that <br /> setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter <br /> zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br /> perimeter zone temperature in heating <br /> C403.2.4.1.1 Heat pump supplementary Indicate staged heating operation with compression as the first stage of heating and <br /> heat supplemental heating controlled with outdoor lock-out temperature set to 40°F or less <br /> C403.2.4.1.2 Deadband Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that Yes <br /> control both heating and cooling <br /> If separate heating and cooling systems with separate thermostatic control devices are used to <br /> Setpoint overlap restriction serve a zone,indicate locations of both thermostatic control devices and the zone they serve <br /> C403.2.4.1.3 (thermostats) on plans <br /> Indicate a limit switch,mechanical stop or DDC control with programming to prevent <br /> simultaneous heating and cooling <br /> C403.2.4.2 Indicate zone thermostatic controls configured with required automatic setback and manual <br /> C403.2.4.2.1 Automatic setback and override functions,setback temperatures,and control method(automatic time clock or <br /> C403.2.4.2.2 shutdown programmable controls);note exceptions taken <br /> C403.2.4.2.3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served <br /> up to design temperature just prior to scheduled occupancy <br /> C403.2.4.3 Outdoor supply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment <br /> operation;not including economizer cooling,night flush or IMC required OSA/exhaust <br /> C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of <br /> dampers power) <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> C403.2.4.4 Zone isolation controls are expected to be occupied non-simultaneously;indicate controls that allow for independent <br /> space conditioning of isolation zones;or exception taken <br /> C403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automatically shut off <br /> heating system when area served is unoccupied <br /> C403.2.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature <br /> exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40°F <br /> C403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or <br /> controls conditions protect fluid from freezing <br /> Group R1 hotel/motel For hotels and motels with over 50 guest rooms,indicate automatic controls serving guest <br /> C403.2.4.9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at <br /> least 5°F;indicate control method-activated by room entry or occupancy sensor <br /> f; <br />
The URL can be used to link to this page
Your browser does not support the video tag.