My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY NORTH CORNER STUDIOS 2019-01-28
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
NORTH CORNER STUDIOS
>
607 SE EVERETT MALL WAY NORTH CORNER STUDIOS 2019-01-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2019 1:51:17 PM
Creation date
1/28/2019 1:51:10 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
NORTH CORNER STUDIOS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: NORTHCORNER STUDIOS(FITNESS CENTER) !Date 8.29.17 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the Washington <br /> State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> Item 3 rooms control of all installed luminaires and switched receptacles in guest <br /> room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy control <br /> Item 4 lighting for supplemental task lighting,including under-shelf or under- <br /> cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications,include <br /> sq.ft.area of each lighting control zone; <br /> C405.2.5- Lighting for non-visual Indicate on plans that non-visual lighting are controlled <br /> Item 5 applications independently from both general area lighting and other lighting <br /> applications within the same space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or demonstration <br /> C405.2.5- Lighting equipment for are controlled independently from both general area lighting and <br /> Item 6 sale or demonstration other lighting applications within the same space; • <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal and <br /> - emergency means of egress illumination; <br /> C405.2.5- Means of egress Provide calculation of lighting power density of total egress lighting; - <br /> Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq.ft., <br /> indicate on plans egress fixtures requiring automatic shut-off <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off control • <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and locations <br /> served; <br /> For building façade and landscape lighting,indicate automatic <br /> Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed <br /> C405.2.7 controls opening/closing time; <br /> For all other exierior lighting,indicate automatic controls shut off • <br /> lighting as a function of available daylight;include control <br /> sequence that also reduces lighting power by at least 30% <br /> between 12am-6am,or from 1 hour after closing to 1 holm: <br /> opening,or based upon motion sensor <br /> Exterior building For building grounds-fixtures greater than 100 watts,indicate on <br /> C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or;are <br /> controls controlled by motion sensor,or are exempt lighting per C405.5.2 <br /> Indicate location(s)of master control switch(es)intended to control <br /> Area controls-Master multiple independent switches;circuit breaker may not be used as <br /> C405.2.5 control switches and a master control switch; <br /> circuit power limit Verify that no 20 amp circuit controlled by a single switch or <br /> automatic control is loaded beyond 80% <br /> - To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed and <br /> • <br /> C406.4 Enhanced digital provided with continuous dimming,or exception taken; <br /> lighting controls Include calculation of percent total installed interior lighting power <br /> that is configured with required enhanced lighting control functions <br /> (min 90%to comply with additional efficiency package option) <br /> • If claiming lighting system commissioning exemption provide <br /> supporting calculation; <br /> C405.13 Lighting system Identify applicable commissioning documentation requirements per ,. <br /> C408.3 functional testing Section C408 or eligibility for exception; <br /> Provide written procedures for functional testing of all automatic <br /> controls and describe the expected system response - <br /> • <br /> ery,y) <br /> xt, <br />
The URL can be used to link to this page
Your browser does not support the video tag.