Laserfiche WebLink
Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: NORTHCORNER STUDIOS(FITNESS CENTER) (Date 8.29.17 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the Washington <br /> State Energy Code,Commercial Provisions. <br /> Applicability Location In Budding Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> C405.2 Lighting controls, For all lighting fixtures,indicate lighting control method on plans for <br /> general spaces and lighting zone(s)served,or exception taken <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of C405.2 <br /> C405.2 lighting controls lighting controls;provide description of control capabilities and <br /> (LLLC) performance parameters <br /> Lighting in dwelling For permanently installed lighting fixtures in dwelling units,indicate <br /> C405.1 lighting control method on plans for spaces and lighting zone(s) <br /> units served,or demonstrate compliance with high efficacy exception <br /> C405.2.3 Indicate on plans the method of manual lighting control(whether <br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction, <br /> C405.2.2.2 Manual controls daylight responsive or specific application controls),location of <br /> C405.2.4 manual control device and area or specifice application it serves <br /> C405.2.5 <br /> C405.2.2.1 Manual interior lighting Indicate on plans which method of manual 50%lighting load <br /> C405.2.2.2 reduction is provided,or whether lighting load is reduced via <br /> C405.2.3 controls occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control during <br /> unoccupied periods(occupancy sensor or time switch)for all <br /> C405.2.2 Method of automatic lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which time <br /> switch control exception applies <br /> Indicate on plans the spaces served by occupancy sensors; <br /> C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to be <br /> C405.2.1.1 controls manual-on,automatic 50%-on,or serve a space eligible for <br /> automatic 100%-on per exception <br /> C405.2.1.2 Occupancy sensor Indicate aisleways and open areas in warehouse spaces provided <br /> controls-warehouses with occupancy sensor controls that reduce lighting power by 50% <br /> C405.2.6 Digital timer switch Indicate required digital timer switch control function when control <br /> is used <br /> C405.2.2.1 Automatic time switch Indicate locations of override switches on plans and the lighting <br /> controls zone(s)served,include area sq.ft. <br /> Indicate primary and secondary sidelight daylight zone areas on <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include sq.ft.; <br /> C405.2.4.3 Sidelight and toplight For small vertical fenestration assemblies(rough opening less than <br /> 10 percent of primary daylight zone)where daylight responsive <br /> controls are not required,provide fenestration area to daylight zone <br /> calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive <br /> controls; <br /> Identify sidelight and toplight daylight zones that are not provided <br /> Daylight responsive with daylight sensing controls and the exception(s)that apply; <br /> C405.2.4 controls Indicate on plans the lighting load reduction method-continuous <br /> dimming,or stepped dimming that provides at least two even steps <br /> between 0%-100%of rated power; <br /> Indicate that daylight sensing controls are configured to completely <br /> shut off all controlled lights in the lighting zone <br /> Additional controls Identify spaces and lighting fixtures on plans that require specific <br /> C405.2.5 Specific application <br /> lighting controls application lighting controls per this section <br /> Indicate on plans that display and accent lighting,and display case <br /> C405.2.5- Display and accent lighting are controlled independently from both general area <br /> Items 1&2 lighting lighting and other lighting applications within the same space; <br /> Indicate manual and automatic lighting control method <br /> (1-...._..167.../1/12 <br />