4. The drawings should indicate specific signage at the main entrance door and the kitchen <br /> egress doors to indicate that these doors will be open during business hours, per IBC <br /> section 1010.1.9.3, item 2.2. <br /> a. The door schedule should indicate that any locking devices on these doors are <br /> readily distinguishable as being locked. <br /> Construction <br /> 1. The removal of exterior canopies and exterior roofing elements should be shown in <br /> section with the replacement proposed. Reference the Energy comments for building <br /> envelope compliance. <br /> Accessibility <br /> 1. A van accessible parking space is required in addition to a second accessible parking <br /> space, based on the number of stalls shown. Please locate and dimension both the <br /> accessible and the van accessible stalls (with access aisles). The van accessible stall <br /> should be shown as being 16 feet wide, per ICC-A117.1-2009 section 502.2. <br /> a. The location of the accessible parking should continue to be on the shortest <br /> route to the primary use and accessible building entrance, per IBC section <br /> 1106.6 and IEBC Section 1105.1. Please indicate conforming curb cuts and <br /> accessible door hardware on the drawings. <br /> Energy <br /> 1. Comcheck does not apply in WA State, since the state has adopted a state-wide energy <br /> code WSEC (which although similar, is a complete replacement to the IECC). There are <br /> similar forms available on neec.net to demonstrate lighting and building performance <br /> compliance. Please submit those completed reports instead of ComCheck reports, which <br /> exclusively applies to the IECC. <br /> 2. Minimum prescriptive requirements for the building thermal envelope should be shown <br /> in section for all removed exterior cladding, to meet minimum prescriptive requirements, <br /> per WSEC section C503.3.1. <br /> 3. Please include actual code section language on the building drawings submitted for <br /> permit, for interior lighting controls, sensors, and all other methods of compliance <br /> covered in electrical power and lighting systems per WSEC section C405. <br /> 4. Please indicate the prescriptive method of building envelope compliance on sheet G1.1, <br /> to include detailed R-Values of modified exterior walls, roof-ceiling cavities, or <br /> replacement roofing, per WSEC section C402.1. <br /> 5. Accessible parking signage should indicate compliance with height and content of <br /> signage per ICC/ANSI A117.1-2009 section 502.7. <br /> All codes cited refer to the 2015 International Building Code (IBC), the 2015 International <br /> Existing Building Code (IEBC), the 2015 International Property Maintenance Code (IPMC), the <br /> 2015 International Fire Code (IFC), the 2015 International Mechanical Code (IMC), and the <br /> 2015 Washington State Energy Code (WSEC), as amended by the State of Washington and <br /> adopted by the City of Everett. The current IBC referenced standard for accessible design is <br /> the 2009 "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA <br /> regulations and standards may be more restrictive. Compliance with these regulations is the <br /> responsibility of the owner of the building. <br /> CITY OF EVERETT PERMIT SERVICES 3200 CEDAR ST, EVERETT, WA 98201 425-257-8810 <br /> website:www.everettwa.gov/permit January 24, 2017 email:everetteps@everettwa.gov <br />