Laserfiche WebLink
i <br /> INTERPLAIC <br /> KFC- Everett, WA <br /> April 20, 2017 <br /> Page 2 of 4 <br /> Occupancy <br /> 3. Comment: The maximum occupant load referenced on the cover page should be <br /> included in the note on F-1 on Sheet A-i.0. <br /> Response: Note amended, please refer to note F-1 on Sheet A-1.0 <br /> 4. Comment: The original permit B9410-12 included automatic fire detection. <br /> Please include that requirement in the code analysis on the cover sheet. <br /> Response: Please refer to updated code analysis on Sheet G-1.0. <br /> 5. Comment: Two exits from the public space should be shown on the drawings, <br /> or the posted occupant load should be reduced to 49 maximum. <br /> a.) A discernible path of egress should be shown with illuminated <br /> exit signs on the drawings, per IBC section 1011.1. <br /> b.) Emergency lighting should be shown on the drawings, per IBC <br /> Section 1006.1. <br /> Response: Two are shown, please refer to Fixture&Graphics Placement Plan on Sheet <br /> A-1.1. Please see Reflected Ceiling Plan on Sheet A-1.0 for Emergency <br /> Lighting, refer to note C20. <br /> 6. Comment: The drawings should indicate specific signage at the main entrance door <br /> and the kitchen egress doors to indicate that these doors will be open <br /> during business hours, per IBC section 1010.1.9.3, item 2.2. <br /> a.) The door schedule should indicate that any locking devices on these <br /> doors are readily distinguishable as being locked. <br /> Response: See General Notes on Sheet A-1.1. Signs are to be provided by separate <br /> signage vendor. <br /> Construction <br /> 7. Comment: T emoval of exterior canopies and exterior roofing elements should <br /> •e shown in section with the replacement proposed. Reference the <br /> Energy comments for building envelope compliance. <br /> Respons,: Please refer to Sheet D-1.0, Detail 1-0 & and note El on the Demoliti. <br /> Elevations. <br /> c'eQ` 1 0 s <br />