My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7407 EVERGREEN WAY KENTUCKY FRIED CHICKEN 2019-02-05
>
Address Records
>
EVERGREEN WAY
>
7407
>
KENTUCKY FRIED CHICKEN
>
7407 EVERGREEN WAY KENTUCKY FRIED CHICKEN 2019-02-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2019 2:49:47 PM
Creation date
2/5/2019 2:49:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7407
Tenant Name
KENTUCKY FRIED CHICKEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INTERPLANs <br /> KFC- Everett, WA <br /> April 20, 2017 <br /> Page 3 of 4 <br /> Accessibility <br /> 8. Comment: A van accessible parking space is required in addition to a second <br /> accessible .arki • .. - .. -d on the number of stalls shown. Please <br /> locate and dimension both the accessible and the van accessible stalls <br /> (with access aisles).The van accessible stall should be shown as being <br /> 16 feet wide, per ICC-A117.1-2009 section 502.2. <br /> a.) The location of the accessible parking should continue to be on the <br /> shortest route to the primary use and accessible building entrance, per <br /> IBC Section 1106.6 and IEBC Section 1105. Please indicate conforming <br /> cur. •.. accessible door hardware on the drawings. <br /> Response* LENDLEASE to provide. � %-•- id If��,e . <br /> Energy No� ` 1, <br /> 9. Comment: ComCheck does not apply in WA State, since the state has adopted a <br /> state-wide energy code WSEC (which although similar, is a complete <br /> replacement to the IECC).There are similar forms available on neec.net <br /> to demonstrate lighting and building performance compliance. Please <br /> submit those completed reports instead of ComCheck reports,which <br /> exclusively applies to the IECC. / <br /> Response: WSEC report included in re-submittal. �/ <br /> 10. Comment: Minimum prescriptive requirements for the building thermal envelope <br /> should be shown in section for all removed exterior cladding, to meet <br /> minimum prescriptive requirements, per WSEC section C503.3.1. <br /> Response: Scope of work does not modify any exterior cladding. <br /> 11. Comment: Please include actual code section language on the building drawings <br /> submitted for permit , for interior lighting controls, sensors, and all other <br /> methods of compliance covered in electrical power and lighting systems <br /> per WSEC section C405. <br /> Response: Please refer to Sheets, G-2.0, G-2.1, G-2.2&G-2.3. ,/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.