Laserfiche WebLink
equipment or documentation must be submitted which demonstrates NSF equivalency. Manufacturer names <br /> and model numbers for replacement equipment or equipment documentation must be submitted prior to the request <br /> for a preoperational inspection. Originally submitted manufacturer names and model numbers should be rechecked <br /> to assure the information submitted is accurate. Please note that subsidiary manufacturers are often not found in <br /> the NSF and equivalent listings. The manufacturer name should be verified and submit the parent company name if <br /> one is found. <br /> 13. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food preparation <br /> counters and tables. Sinks in corners must also have wall protection on the side walls. A 16-inch high backsplash <br /> of plastic laminate, fiberglass-reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is <br /> required on the wall behind counter top equipment taller than 16 inches.. Floor to ceiling protection is required on <br /> the wall behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br /> hardboard is not acceptable. <br /> 14. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be surfaced with <br /> a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and the like in concrete <br /> floors in all areas, including customer seating areas, must be filled and sealed so as to provide a smooth and <br /> cleanable surface. <br /> 15. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and easily cleanable. <br /> 16. Cabinet shelving must be nonabsorbent,smooth and easily cleanable. (Self stick vinyl or other type surfaces are <br /> not acceptable) <br /> 17. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof bulbs. <br /> 18. Plumbing must meet state and local codes. <br /> 19. It cannot be determined from the floor plan or information submitted whether or not a chemical dispensing system <br /> will be installed at the mop sink. Please note that the use of screw-on type `wye' adaptors at the mop sink faucet <br /> for use with chemical dispensing systems is prohibited. Additionally chemical dispensers cannot be connected to <br /> the mop sink faucet. The chemical dispenser must have a separate water connection. A`sidekick' adaptor at the <br /> mop sink faucet is acceptable. <br /> A preoperational inspection is required prior to operating permit issuance and approval to open for business. <br /> At the time of inspection the construction of the food service establishment must be complete and all equipment must <br /> be in place and in proper operating condition. Incomplete construction or equipment operation will result in a $180.00 <br /> re-inspection fee. Contact the Food Program office a minimum of one week in advance to schedule an <br /> appointment for the preoperational inspection.The preoperational inspection will ensure compliance with the Rules <br /> and Regulations of the State Board of Health for Food Service Sanitation. <br /> Changes or additions to.the approved plans or equipment require pre-approval from the Snohomish Health District prior <br /> to implementation of the changes. <br /> Please contact me if you have any questions. My office number is 425.339.8742 and my email address is <br /> ehaqedornsnohd.orq. <br /> Sinc- ely, <br /> Elai Hagedorn, R <br /> Environmental Health Specialist <br /> Food Establishment Plan Review <br /> EH/kdc <br /> Enclosure:Annual Food Establishment Permit Application, Fee Schedule—Food Safety <br /> cc: City of Everett Building Department <br /> WA State Liquor Control Board <br /> Robbie Evjue, Environmental Health Specialist <br />