My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3703 RAILWAY AVE KIMBERLY CLARK 2018-01-01 MF Import
>
Address Records
>
RAILWAY AVE
>
3703
>
KIMBERLY CLARK
>
3703 RAILWAY AVE KIMBERLY CLARK 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 7:45:11 AM
Creation date
2/13/2019 7:41:51 AM
Metadata
Fields
Template:
Address Document
Street Name
RAILWAY AVE
Street Number
3703
Tenant Name
KIMBERLY CLARK
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ocizsio2 in:zo FAT I�oio <br />•� �V.1'T�R ATSTRIBiTTION <br />5-5.6 LOOPED MAIIVS <br />Jnless otherwise approved by the city, dead entiing of water main will not be permitted. All dead ends <br />must be looped to existin; water mains. In the e�•�n[ it is necessary for the developer to obtain ar. <br />easement for the city thzou;h private property to accomplish ]ooping of thc dcad end, the easement shall <br />be a minimum of 15 feet wide. <br />5-9 S�tVICE LINi�S <br />5-9.1 GENERAL <br />Service lines from the wat�:r main to the meter for all services 2 inches an.i smailer shall be copper or <br />polyethylene tubi+�. A nwnUcr 10 copper u�aca wire is required for po]yethylene pipe. A�l service lines <br />3 mches and larger shall he cement lined ductile iron pipe from the main to the meter. <br />All service connecuon pipiig within the public right-of-way shall be a minimum of 30 inches below the <br />finish grade surface. For fiirther details on services and hook-ups, see Standazd Nos. 502A and 502H. <br />On services installed in co�ijunction with new watcr mains, it is required that the services be installed <br />from the main to the permanent curb stop and be subjected to purity and hydrostatic testing wich the new <br />water main as detailed in Sections 5-1�. and 5-15. <br />5-9.2 MATER3ALS <br />Copper tubing shall conforni to the requirements of ASTM B88, Type B, annealed. The tubing shall b� <br />coupled using flare-type con�pression fittings conforming to the requiremen�s of AWR'A C800, minimum <br />150 psi worldng pressure. <br />Pclyethylene rubing shall conform to tlie requirements of AWWA C901. The pipe shall bear the seal of <br />the Narional Sanitarion Foui�dation for potaUle water pipe. Pipe joinu shall be made in accordaDce with <br />tbe manufatturer's recommendations. Solvent welded pipe joints will noc be nermiaed. Ivlinimum <br />worldng pressure shall be lii0 psi. 2" service shall be copper tube size (CT5), 'k" and 1" service shall <br />be iron pipe size (IPS). <br />Ductile iron pipe shzll coafo:rm to the requirements shown in Section 5-6.2 of these Standaids. <br />5-9.3 CONNECTIOr'S <br />Service connections on 4 inc,h ducrile iren ,nains or for any service 2 inches or larger shall be installed <br />witL Mueller, Rockwell, Romac or approved equal pipe saddles. birect taps may be ma�ie for 3/4 inch <br />and 1 inct� services on ducul�_ iron pipe 6 inch I.D. or larger. The minimum acteptable tap size shall be <br />3/4 inch. <br />No scrvice connections may be installed on fire service mains or on 5re hydrant laterals between the <br />hydrant valve ;u�d the fire hy�iranc <br />5-10 VALVFS FOR ViA�'�.R MAINS <br />5-10.1 CEIVERAI, <br />All valves s�all be inspectcd tipon deli��ery in the field to ensure proper worldng order before installadon <br />and shall t,; free of all rust a�id dirt. 'I'hey shall be set and iointed to the pipe in the manner as set forth <br />in the AWWA 5tandazds for the type of connectin� evds fu;nished. Tt�e valves shall also be carefully <br />� spected for injury to the out:r protective coatings. <br />S7ANDARD9 Sdu <br />Rw. 10lOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.