My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1110 RAINIER AVE A DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1110
>
DOMESTIC VIOLENCE SERVICES OF SNO CO
>
1110 RAINIER AVE A DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 10:32:45 AM
Creation date
2/13/2019 9:24:55 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1110
Unit
A
Tenant Name
DOMESTIC VIOLENCE SERVICES OF SNO CO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
252
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r� <br />►� <br />Everett No��singAuthority <br />May 16, 'LOt 2 <br />� <br />JN 12080 <br />Page 5 <br />Depending on the final site grades, overexcavation may be required below the (oolings to expose <br />competent native soil. Unless lean concrete is used to fill an overexcavated hole, the <br />overexcavalion musl be at least as wide at the bottom as ihe sum of the deplh of the <br />overexcavation and the footing v�idlh. For example, an overexcavation extending 2 feet below the <br />bottom o( a 2-foot-witle footing must be at I�ast 4 feet wide at the base oi the excavation. Ii lean <br />concrete is used, the overexcavation need only extend 6 inchos beyond the edges of lhe footing. <br />An allo�.vable bearing pressure of 3,000 pounds per square fool (psf) is appropriale for footings <br />supported on competent soil and/or structural fill as noted above. A one-third increase in this <br />design bearing pressure may be used when considering short-term wind or seismic loads. For the <br />above design criteria, it is anticipated that the total post-construction settlement of footings founded <br />on competent native soil, or on structural fill up to 5 feet in thlckness, �vill be about one inch, with <br />differenlial settlements on the order of one-half inch in a distance of 50 feet along a continuous <br />footing �vith a uniform load. <br />Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and <br />the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the <br />foundation. For the latter condilion, the foundation must be either poured directly againsi relatively <br />level, undisturbed soii or be surrounded by level, compad fill. If the ground in front of a(oundation <br />is loose or sloping, the passive eartn pressure given above will not be appropriate. We <br />recommend using the following uitimate values for the tcundation's resistance to lateral loading: <br />Coefficient of Friclion 0.50 <br />Passive Earth Pressure 300 pcf <br />Whero: (1) pcf Is pounds per cubic loot, and (I1� passivo earth <br />p�nssuro Is eomputed us(ng the equlva�ent IIuId densily. <br />We recommend maintaining a safety (actor of at least 1.5 `or the foundation's resistance to 12teral <br />Ioading, �vhen us�ng the above ultimate values. <br />PlPE PILES <br />Three-, 4- or G-inch-diameter pipe piles driven tvith a 800- or 1,100•pound hydraulic jac�chammer to <br />the (ollovr.ng final peneL�ation rates may bc assi�ned lhe (ollo�vfng compressive cap3citi�s. <br />_3 inches _ 1 ___ 10 sec'inch � n secl�nch n�a �__ 6 lon; ; <br />v inches 15 seGinch � 10 seclinch 5 seclinch 10 tons � <br />6 inches n/a �� 20 seclinch �� 10 sec/inch �_ 20 tons <br />Note: The refusal criteria indicated in the above table are valid only for pipe piles ihat are <br />installed using a hydraulic impact hammer carried on leads that allow the hammer to sit on <br />GEOT[CH COIJSULTANTS,iNC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.