Laserfiche WebLink
� <br />Evare(f Housing Authoriry <br />P�iay i6. 2012 <br />� <br />�r� izoeo <br />Page G <br />the top of the pile during driving. If the piles are instailed by alternative melhods, such as a <br />vibratory hammer or a hammer that is hard-mounted to the installation machine, numerous <br />load tesls to 200 percent of the design capacity would be necessary to substantiate the <br />allo�vable pile load. The appropriate number of load tesis wouid need to be determined at <br />the time the contractor and installation method are chosen. <br />Although it is difficult to determine lhe final depths of the piles, we 2nticipate approximateiy 10 (eel <br />of pile embedment into ihe compelent native soils lo achieve the noted capacities. <br />As a minimum, Schedule 40 pipe should be used. Due to the existence of peat soils, which can <br />corrode metai, we recommend the piles be galvanized. Pile caps and grade beams should be used <br />to transmit loads to the piles. Isolated pile caps should include a minimum of two piles to reduce <br />the potential for eccentric loads being applied fo the piles. Subsequert sections of pipe can be <br />connected with slip or threaded couplers, or they can be welded together. If slip couplers are used, <br />they should fit snugly into the pipe sections. This may require that shims be used or that beads of <br />welding ti�x be applied to the outside o( the coupler. <br />Lateral :oads due to wind or seismic forces may be resisted by passive earth pressure acting on the <br />verlical, embedded portions of the foundation. For this condition, the foundation must be either <br />pourea dlrectly against relatively level, urdislurbed soil or be surrounded by level compacled fill. <br />�Ne recommend using a passive earlh pressure of 300 pounds per cubic foot (pcf) for lhis <br />resistance. If the ground in front of a foundation is loose or sloping, the passive eaRh pressure <br />given above will not be appropriate. �Ve recommend a satety factor of at Ieast 1.5 for the <br />(oundation's resistance !o lateral loading, when using the above ultimate passive value. <br />Due to their smail diameter, the later2l capacity of vertical pipe piles is reiatively small. However, if <br />laleral resistance in addilion to passive soil resistance is required, we recommend driving battered <br />piles in lhe same direction as the applied laterel load. The lateral capac�ty of a baltered pile is <br />equal to one-half of ihe lateral component of the allo�vable compressive load. The allo�.vable <br />vertical capacity oF battered piles does not need to be reduced if the piles are battered steeper than <br />1:5 (Horizontal:Vertical). <br />PERMANENT FOUNDATION AND RETAIN/NG WALLS <br />Retaining walls backfilled on only one side should be designed to resist ihe lateral earth pressures <br />imposed by ihe soil ihey retain. The following recommended parameters are for walls lhat resirain <br />level back(ill: <br />Activc Earth P�� c.:ure ' � 35 pd <br />Passive [a�th Pressure � 300 pcf <br />Whoro: (I) pcf Is pounds por cub�c lool, and (il) aclive an� <br />passive earth pressures are camputed using tho equivalenl IIuiU <br />pressuros. <br />• For a restrained v�all that cannot dellect at Ieast 0.002 times Its <br />helght, a unlfarm latoral pressurc equal to �0 psl tlmos the hal9ht <br />al tho wall should be addod lo lha �6ovo ac!ive equlvalont fluid <br />prossure. <br />GEOTECH COYSULT�NTS,INC. <br />