My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1110 RAINIER AVE A DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1110
>
DOMESTIC VIOLENCE SERVICES OF SNO CO
>
1110 RAINIER AVE A DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 10:32:45 AM
Creation date
2/13/2019 9:24:55 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1110
Unit
A
Tenant Name
DOMESTIC VIOLENCE SERVICES OF SNO CO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
252
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />Everatt Housing Fl ufhority <br />M2y 16, 2012 <br />� <br />JN 12080 <br />Pac,e 7 <br />The vaiues given above are to be used to design only permanent foundation and retaining walls <br />that are to be backfilled, such as conventional �valls constructed of reinforced concrete or masonry. <br />It is not appropriate to use the above earth pressures and soil unit eveight to back-calculate soil <br />strength parameters for design of other types of retaining walls, such as soldier pile, reinForced <br />earth, modular or soil nail walls. We can assist �vith design of these types of walls, if desired. The <br />passive pressure given is appropriate only for a shear key poured directly against undisturbed <br />native soil, or for the depth of level, compact fill placed in front of a retaining or foundation wall. <br />The values (or friclion and passive resistance are ultimate values and do not inc{ude a safety <br />factor. We recommend a safety factor of at least 1.5 for overturning and sliding, when using the <br />above values to design the walls. Restrained �vall soil parameters should be utilized for a distance <br />of 1.5 times the wall height from corners or bends in the walls. This is intended to reduce the <br />amo�nt of cracking that can occur where a wall is restrained by a corner. <br />The design values given above do rot inciude the effects of any hydrostatic pressures behind the <br />walls and assume that no surchar5es, such as those caused by slopes, vehicles, or adjacanl <br />foundalions will be exerted on the ��•alis. If these conditions exist, ihose pressures should bo added <br />to the above laleral soil pressures. Where sloping backfill is desired behind the walis, we �vill need <br />to he given lhe wall dimensions and ihe slope oF the backfill in order to provide the appropriate <br />design earih pressures. The surcharge due to lraKc loads behind a wall can lypically be <br />accounted for by adding a uniform pressure equal to 2 feet multiplied by the above active (luid <br />density. Heavy construction �quipment should not be operated behind relaining and foundation <br />walls wilhin a distance equal to the height of a wail, unless the walls are designed tor the addl:ional <br />Iaterai pressures resulting irom the equipment. <br />Wall Piessures Due to Seismic Forces <br />The surcharge wall Ioads that couid be imposed by ihe design earlhquake can be modeled <br />by adding a uniform lateral pressure to lhe above-recommended active pressure. The <br />recommended surcharge pressure is 8H pounds per square foot (psf), where H is lhe <br />design reter�tion height of the wa11. Using this increased pressure, the safety factor against <br />sliding and overturning can be recuced to 1.2 for the seismic analysis. <br />Retaininq Wall Backfill and Waterproofinp <br />Backfill placed behind retaining or foundalion �valls should be coarse, free•draining <br />siructural (ill containing no organics. This backfill should contain no more lhan 5 percent silf <br />or clay particles and have no gravel greater than 4 inches in diameter. The percentage of <br />particles passing the No. 4 sieve should be between 25 and 70 percent. The later section <br />entitlod Drainage Considerations should also be reviewed for recommendations relaled to <br />subsurface drainage behind foundation and retaining walls. <br />The purpose of these backfill requirements is lo e�sure that the design criteria for a <br />retaining wall are not exceeded because of a build•up o( hydrostatic pressure behind the <br />wall. The top 12 to 18 inches of the backfill should consist of a compacted, relatively <br />impermeable soil or topsoil, or the surface shoutd be paved. The ground surface must also <br />slope away from backiilled walls to reduce lhe potential for surface �vater to percolate into <br />Ihe backfill. <br />It is critical Ihat the wall backfill be placed in lifts and be properly compacted, in order for the <br />above•recommended design earih pressures to be appropriale. The wall design criteria <br />GEOTECH CONSULTANTS.INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.