Laserfiche WebLink
ARC?RCHITECTS.COL1 �t f FIY�_'.T•� _^�F 1 � ��TIL':'.- -"�7: .. . ... '77.: ? ::6 •,-' <br />Response: Noted on the Building Code Data on sheet T7.0. <br />�2 If this �s not a sprinklered bwlding w�th a detection system, please note that on ihe code analysis <br />Response: Not a sprinklered building. No detection system. Noted in the Building Code Data <br />on shcet T1.0. <br />Egress <br />� 1 Where changes of elevation occur in the means o( egress, those details should be shown r� :tie <br />drawings, per IBC chapter 10. <br />Response: No changes of elevation occur in the means of egress. A new landing will be <br />added at door 100•2E to integrete seamlessly wilh existing exlerior grade. See iloor plan for <br />extent of new work. <br />� 2 The signage per IBC seciion 1008.1.9 3 should be shown on the egress side (inside) on the <br />tlrawings CurrenU} this sign is shown to be posted on the outside of the building on the drawings <br />Response: Gorrections made on sheet A2.1 to indicate sign on egress side (inside). <br />� 3 If the exit discharge is locat:d where access to a public way cannot be provided, a safe d�spersal <br />area shouid be shown on the architeclura� site plan, per IBC sec6on 1027.6. <br />Response: Access to a public way cao 6e provided. Please refer to the partial site plan nn <br />A 2.0. <br />Construction <br />f 1 The construction type of the building should be shown in the code analysis, per IBC table 503 <br />Response: Please refer to Building Code Data or sheet T1.0 <br />� 2 A new guard should be shown in detail and dimensions for the mechanical mezzanine, per IMC <br />sachon 304.1 t, d the mezzanine will stiil be used for mechanical access <br />Kesponse: Please re(er to lhe seclions on sheet A2.2. See structurel detail in separa[e <br />documenl, and on 31A�.1 <br />� 3 For bolh required exds, please prowde a section through the lhreshoids connec6ng Youth Center <br />�vlth ihe exterior landings, per IBC section 1008 1 5 <br />Response: Piease find the typical threshold detail 41A2.1. <br />Accessibility <br />�t A change oF occupanr,y lo A-3 should include the following accessib�liry iewsions shown on the <br />ar�hdeciurel sde plan, per IBC sec6ons 3411.42 and 1104 1 <br />• One accessible building entrance <br />• An accessible route connecting zccessible parking to an accessible entra��ce. <br />Response: Not A-J. <br />J2 Ailerations only (B occupancy) reqwre an accessible enlrance to the primary function area, per IBC <br />section 3411 ] The draw�ngs and supporting documents should mdicate that at least 20% of the <br />costs o( the altera6ons aftecting the area of pnmary function have been allocated to lhls <br />requirement. <br />Response: One accessible entrance is provided ro the primary function area. Costs ot <br />providing lhis are not required to exceed 20% o( the costs of the alterations aHecting the area <br />o( primary tunc[ion, per IEiC 31� 1.7, Exception 1. <br />