My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1110 RAINIER AVE B DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
>
Address Records
>
RAINIER AVE
>
1110
>
DOMESTIC VIOLENCE SERVICES OF SNO CO
>
1110 RAINIER AVE B DOMESTIC VIOLENCE SERVICES OF SNO CO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2019 10:30:42 AM
Creation date
2/13/2019 10:00:42 AM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
1110
Unit
B
Tenant Name
DOMESTIC VIOLENCE SERVICES OF SNO CO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARCARCNITEGTS.COId i'��f_FIMrST-�"_b.:P•?:r:.TTL=`•::.°<'I:: ._�:3:J2_.^�' �Jfil�l2�� <br />� Both toilet rooms should be shown wdh s�gnage on the plans as unisex, whzre the new toilet room is <br />also signed as accessible, to comply with IBC seclions 29022 and 1109.2 <br />Response: Signage will be provided. Please refcr to plans and detail sheet A3.1 <br />Ene�gy <br />,/1. A change of occupancy to A-3 requires that the building envelope shoulo be shown on the drawings <br />to meet the requirements for a new building, per WSEC C101 A <br />a. Calculations should be submdted Wall sections and materials should be shown on the <br />drawings with the component R or U values referenced in the calculations <br />Response: Not A-3 <br />J 2 Atterations for a B occupancy require that the altered areas comply wdh the current energy code, per <br />WSEC sectian C701 4.3 <br />Response: See Energy Code notes on sheet T1.0. Added insulation at walls is shown in the <br />sections. Thermal requirements for new doors are included in tlie Building Code Data on <br />sheet T�.O. <br />� 3 Details for building envelope compliance required (or the energy code should be targeted and shoem <br />on the drawings. <br />a. Where mechanlcal and electrica� compliance requirements are not shown on lhe draw�ngs. <br />they should be scaped for deferred permils. <br />Response: See cover page notes regarding deferred permits. <br />� 4 The method of changing the build�ng envelope to comply with lhe mechanical code reqwremenis o( <br />outside a�r requirements should be shown on the drawings, per IMC table 403.3 and WSEC secl�on <br />C402. <br />JResponsc: See cover page notes regarding deferred permits. <br />5 Please show or scope lighting reduction controis on the drawings, per WSEC C4052 7 2 <br />J Response: See cover page notes regarding deferred permits. New light at ADA restroom to <br />be provided with vacancy sensor. See note on RCP, 3/A2.1. <br />6 Please show or scope additional hghting coNrols on the drawings, per WSEC C40522. <br />Responsc: Sce cover page noles regarding deferred permi[s. Ncw light at ADA restroom to <br />liave manual s�vitching. See note on RCP. 31A2.1. <br />[nd of Document <br />3/� <br />
The URL can be used to link to this page
Your browser does not support the video tag.