ABBREVIATIONS FL FLOOR PS PAINT SYSTEM SYMBOLS NDO WINDOW BUG GENERAL N�TES <br /> FLG FLASHING PSF POUNDS PER SQUARE FOOT � <br /> � ANGLE FLUOR FLUORESCENT PSI POUNDS PER SQUARE INCH 1. THE GENERAL CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFEIY OF ALL <br /> � CENTER LINE FM FACTORY MUTUAL PT PRESSURE TREATED A q PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. <br /> INTERIOR ELEVATION(S) SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF � ���' � ����� <br /> � DIAMEfER OR ROUND FOC FACE OF CONCREfE PTD PAPER TOWEL DISPENSER .-- ELEVATION IDENTIFICATION THE CONTRACTOR'S SAFEfY MEASURES. �t <br /> # NUMBER OR POUND FOF FACE OF FINISH PTD/R PAPER TOWEL DISPENSER - � C�JLUMN LINE/GRID LINE D AX.X B 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN <br /> � PENNY FOIC FURNISH BY OWNER AND RECEPTABLE SHEET WHERE ELEVATION IS OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND <br /> � DRAWN SPECIFICATIONS. <br /> PERPENDICULAR INSTALL BY CONTRACTOR PTN PARTITION 3. THE GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED <br /> I� PLATE F010 FURNISH BY OWNER PTR PAPER TOWEL RECEPTABLE ITEMS, WHICH ARE BEING DONE BY OTHERS. <br /> INSTALL BY OWNER PVMT PAVEMENT DOOR NUMBER TITLE ROOM IDENTIFICATION 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY <br /> CORRESPONDS TO ROOM ENTERING TITLE2 DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH <br /> AB ANCHOR BOLT FOS FACE OF STUD ROOM NAME <br /> TITLE3 DISCREPANCIES ARE RESOLVED. <br /> AC ACOUSTICAL OR FS FULL SIZE QT QUARRY TILE ROOM ROOM N0. 5. SEPARATE PERMITS, WHEN REQUIRED AND/OR WHEN WORK ITEMS ARE DESIGN/BUILD IN NATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR <br /> A/C AIR CONDITIONING FT FEEf OX KEY NOTE MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DEfAILED DESIGN AND REQUIRED SUBMITTAL DOCUMENTS <br /> ACP ACOUSTICAL PANEL FTG FOOTING R RISER INFORMATION SHALL BE PROVIDED FOR REVIEW BY THE REGULATING AUTHORITIES AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO a r C h I t e C t S <br /> +8'-�' FINISHED CEILING HEIGHT ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN BUILD FIRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND OBTAIN <br /> ACT ACOUSTICAL TILE FTIC FURNISHED BY TENANT RA RETURN AIR / <br /> ADH ADHESIVE INSTALLED BY CONTRACTOR RAD RADIUS WT PARTITION TYPE PERMIT FROM THE AUTHORITY HAVING JURISDICTION FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. ALL WORK SHALL COMPLY WITH <br /> CURRENT GOVERNING CODES. 2505 Third Avenue <br /> ADJ ADJACENT FTIO FURNISHED BY TENANT RB RESILIENT BASE - - PROPERTY LINE 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL BE PERFORMED BY INSPECTORS APPROVED BY THE BUILDING OFFICIAL. Suite 324 <br /> ADJT ADJUSTABLE INSTALLED BY OWNER R&S ROD & SHELF X REVISION NUMBER 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED Seattle, WA 98121 <br /> AF ACCESS FLOOR FURR FURRING RD ROOF DRAIN NEW OR FINISHED CONTOURS PLANS ARE TO REMAIN ON SITE AT ALL TIMES. ANY MODIFICATIONS TO WORK SHALL BE INDICATED ON FIELD "AS-BUILI" SEf OF DOCUMENTS. <br /> AFF ABOVE FINISH FLOOR FUT FUTURE RD/0 ROOF DRAIN OVERFLOW CLOUD AROUND REVISION �8 `/ 8. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. 206.720.7001 pi-ione <br /> 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 206.720.2949 fax <br /> AL ALUMINUM FUTURE- FUTURE ROUGH IN ONLY REBAR REINFORCING BAR � EXISTING CONTOURS 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DEfAILS SHALL BE THE SAME AS FOR OTHER SIMILAR <br /> ALT ALTERNATE RIO REF REFERENCE - - �1 � WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. <br /> MATCH LINE 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER AND ARCHITECT WITH DEfAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START www-craftarchitects_com <br /> AP ACCESS PANEL FX FIXED REFR REFRIGERATOR _ - SHADED PORTION IS THE SIDE O OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER AND ARCHITECT. <br /> APPROX APPROXIMATE REINF REINFORCED CONSIDERED 1�'� 12. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH CURRENT GOVERNING CODES. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED <br /> ARCH ARCHITECTURAL GA GAGE REQ'D REQUIRED ��� TOP OF WALL AS TO PERMIT WORK WHICH IS NOT CONFORMING TO CURRENT GOVERNING CODES. <br /> ASPH ASPHALT GALV GALVANIZED REV REVISION WORK POINT, CONTROL POINT 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. <br /> GB GRAB BAR RH RIGHT HAND OR ROBE HOOK � � OR DATUM POINT 16p 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICE PROVIDERS, PUBLIC AND/OR PRIVATE. <br /> BD BOARD GL GLASS OR GLAZING RESIL RESILIENT ��� TOP OF CURB 15. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10'-0" O.C. AND ALSO AT ANY LOCATION WHERE WALL FRAMING PENETRATES <br /> BETW BEfWEEN CEILINGS. REFER TO IBC SEC. 708 FIRE BLOCKING AND DRAFT STOPS FOR CONSTRUCTION. <br /> GLBM GLU-LAM BEAN RM ROOM 1492 EQUIPMENT NUMBER 16. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND AFFECTED BY NEW CONSTRUCTION. <br /> BLDG BUILDING GEN CONTR GENEFiAL CONTRACTOR RO ROUGH OPENING 17. PRIOR TO FINAL INSPECTION, A CERTIFICATE OF CONSTRUCTION COMPLIANCE SHALL BE READY FOR THE INSPECTOR. THE CERTIFICATE SHALL STATE <br /> BLK BLOCK GND GROUND RT RESILIENT TILE �5�` TOP OF PAVEMENT "BASED UPON PERSONAL KNOWLEDGE, THAT THE WORK APPEARS TO HAVE BEEN PERFORMED, AND THE MATERIALS USED AND INSTALLED APPEAR IN � <br /> BLDG BUILDING GR GRADE RUB RUBBER BUILDING SECTION �Q• EVERY MATERIAL RESPECT IN COMPLIANCE WITH THE PLANS". THE CERTIFICATE MUST BE SIGNED BY ONE OR MORE OF THE FOLLOWING: <br /> BM BEAM GWB GYPSUM WALL BOARD RVS REVERSE X (A) OWNER, (B) GENERAL CONTRACTOR, (C) AN APPROVED INDEPENDENT INSPECTOR OR INSPECTION AGENCY. � Z <br /> BRG BEARING AX.X SECTION IDENTIFICATION 18. ASBESTOS AND HAZARDOUS WASTE EXCLUSION: O <br /> RW RAIN WATER SHEET WHERE SECTION IS DRAWN THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, � <br /> BOT BOTTOM HB HOSE BIB RWL RAIN WATER LEADER PROJECT (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CIAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM � � <br /> BSMT BASEMENT HC HOLLOW CORE OR HANDICAP NORTH PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED T0, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND � <br /> BUR BUILT UP ROOF N RELATED TO THE INVESTIGATION DETECTION. W <br /> HDR HEADER S SOUTH PROJECT NORTH 19. PROVIDE FIRE EXTINGUISHERS WITH A MINIMUM RATING OF 2A:10B:C IN QUANTITY AND LOCATIONS AS DIRECTED BY THE FIRE MARSHALL, MINIMUM OF � � Z <br /> HDWD HARDWOOD SC SOLID CORE DETAIL SECTION ONE UNIT PER 3,000 SF AND NO MORE THAN 75 FOOT TRAVEL DISTANCE TO ANY FIRE EXTINGUISHER. Q � � � <br /> CAB CABINET HDWE HARDWARE X 20. PROVIDE APPROVED RADIO COVERAGE FOR EMERGENCY RESPONDERS WITHIN THE BUILDING BASED UPON THE EXISTING COVERAGE LEVELS OF THE <br /> CB CATCH BASIN SCD SEAT COVER DISPENSER SECTION IDENTIFICATION � Z � <br /> HM HOLLOW MEfAL SCHD SCHEDULE AX.X PUBLIC SAFEfY COMMUNICATION SYSTEMS OF THE JURISDICTION AT THE EXTERIOR OF THE BUILDING PER INTERNATIONAL FIRE CODE (IFC) SECTION � <br /> CBU CEMENTITIOUS BACKER UNIT HORIZ HORIZONTAL SHEEf WHERE SECTION IS DRAWN g�_p^ DENOTES CHANGE IN 510.1. � a <br /> CEM CEMENT SD SOAP DISPENSER OR ELEVATION Q � <br /> HR HOUR SECT SECTION ��-� _ � <br /> CER CERAMIC HT HEIGHT SF SQUARE FEET � Q w <br /> CFM CUBIC FEEf PER MINUTE HTG HEATING SHTG SHEATHING U W � <br /> CFT CONDUCTIVE FLOOR TILE HVAC HEATING/VENTILIATION/ SIM SIMILIAR r DEfAIL OR ENLARGED PLAN PT FINISH SYMBOL � � � w <br /> CG CORNER GUARD AIR CONDITIONING <br /> CHBD CHALK BOARD SK SINK AX.X DETAIL IDENTIFICATION 2 � � w <br /> HWH HOT WATER HEATER SLR SEALER SHEEf WHERE DEfAIL IS DRAWN <br /> CI CAST IRON <br /> CJT CONTROL JOINT SND SANITARY NAPKIN w � <br /> ID INSIDE DIAMEfER/ DISPENSER � � <br /> CLF CHAIN LINK FENCE DIMENSION <br /> ��� CEILING SNR SANITARY NAPKIN EGRESS SUMMARY LEGEND KEY NOTES� O <br /> IG INSULATED GLAZING RECEPTACLE <br /> CJ CONSTRUCTION JOINT IHM INSULATED HOLLOW MEfAL SNT SEALANT A. MAX. TRAVEL DISTANCE: 200' (TABLE 1016.1 - S-1 OCCUPANCY) NEW EXIT SIGN W EMERGENCY POWER TO MEEf IBC <br /> CLK CAULKING IN INCH 250' EXIT ACCESS DISTANCE INCREASE WHEN FULLY SPRINKLED EXIT SECTION 1011 / �. ACCESSIBLE ENTRANCE/EXIT PER IBC SECTION 1105.1 <br /> CLO CLOSEf SPEC SPECIFICATION <br /> INCL INCLUDE SQ SQUARE FIRE DEPARTMENT ACCESS DOORS PROVIDED AT <br /> CLR CLEAR B. MAX. COMMON PATH OF EGRESS TRAVEL: 75' (1014.3) 100' INCREASE WHEN FULLY SPRINKLED FIRE <br /> INSUL INSULATION INTERVALS LESS THAN 100' SPACING AROUND PERIMETER <br /> CMU CONCRETE MASONRY UNIT SST STAINLESS STEEL OF BUILDING <br /> INT INTERIOR SSK SERVICE SINK C. MINIMUM CLEAR DOOR OPENING: <br /> CNTR COUNTER ST STONE/STONE TILE 32 INCHES (1008.1.1) 1 2 3 4 5 6 7 8 9 b fl 12 <br /> CO CLEANOUT STA STATION CONSULTAWI' <br /> COL COLUMN �TN JONNTOR D. MAXIMUM DEAD END CORRIDOR: FIRE <br /> CONC CONCRETE STC SOUND TRANSMISSION 50 FEET (1018.4) /� <br /> CONSTR CONSTRUCTION CLASS - - - - - - � - - - - - - - -� A ) <br /> KIT KITCHEN STD STANDARD EXIT EXIT EXIT �'� <br /> CONT CONTINUOUS KO KNOCK OUT <br /> CORR CORRIDOR STL STEEL _ _ FIRE _ I FIRE <br /> KS KNEE SPACE STOR STORAGE � � <br /> CPT CARPET - - - B <br /> CT CERAMIC TILE �qM LAMINATE STRL STRUCTURAL � EXIT � EXIT � <br /> CTR CENTER SUSP SUSPENDED I I I <br /> LAV LAVATORY SV SHEEf VINYL <br /> CY CUBIC YARD <br /> LB LAG BOLT SYM SYMMEfRICAL I I <br /> LF LINEAL FOOT <br /> DBL DOUBLE LG LENGTH T TREAD I I I I I I I I I ( I <br /> DEPT DEPARTMENT LH LEFT HAND TB TOWEL BAR I I <br /> DET DETAIL LINO LINOLEUM T&B TOP & BOTTOM <br /> DF DRINKING FOUNTAIN(W/0 COOLER) LKR LOCKER TG TEMPERED GLASS I I ' FIRE ��� R����'�E�' <br /> DIA DIAMETER LT LIGHT THK THICK FIRE 0 _ ARCN�rEc� <br /> DIAG DIAGONAL THR THRESHOLD � � � <br /> STAT£Qf SHiNGTON <br /> DIM DIMENSION MACH MACHINE TIG TEMPERED INSULATED � I I I I I I I I I � , � �� <br /> DISP DISPENSER MATL MATERIAL GLAZING I <br /> DN DOWN MAX MAXIMUM TO TOP OF I I I <br /> DR DOOR OR DRAIN MECH MECHANICAL TOC TOP OF CONCREfE Submittals Revisions: <br /> DWR DRAWER MEf OR MTL MEfAL TOP TOP OF PAVEMENT I I / <br /> DS DOWNSPOUT MEZZ MEZZANINE TOS TOP OF STEEL I I I I I I I I I <br /> DW DISHWASHER MFR MANUFACTURER TOSL TOP OF SLAB � I I I FOR PERMIT 05/04/16 <br /> DWG DRAWING MH MANHOLE TOW TOP OF WALL - - - - - - - - - - � <br /> MIN MINIMUM TPD TOILET PAPER DISPENSER I I I <br /> E EAST MIR MIRROR TPH TOILET PAPER HOLDER <br /> o TRAVEL DIST. 205'-9„ TRAVEL DIST. 237'-0" RAVEL DIST. 242'-11" TRA EL DIST. 222'-4" TRAVEL DIST. 212'-2" <br /> EA EACH MISC MISCELLANEOUS � TPTN TOILET PARTITION — — — — - -�- — — —� — — — — — — — — „� — � � �— � � — � � — — � <br /> EB EXPANSION BOLT TS TUBULAR STEEL TRAVEL DIST. 22h'-2" I TRAVEL DIST. 205 -9 � TRAVEL DIST. 214-7 � XRAVEL DIST. 220 -6 TRAy�EL DIST. 152 -0 I I TRAVEL DIST. 181 -0" � <br /> MLD MOLDING I <br /> EJ EXPANSION JOINT MRGWB MOISTURE RESISTANT GYP BD N TELEVISION FIRE ~TRA DI 20 9" � FIRE <br /> EL ELEVATION MTD MOUNTED TYP TYPICAL I I <br /> ELEC ELECTRIC MULL MULLION UL UNDERWRITERS LABORATORY �� <br /> ELEV ELEVATOR UNF UNFINISHED - - - - - - - - - - - - - - - -{ E ) <br /> EM ENTRY MAT N NORTH UON UNLESS OTHERWISE NOTED �'� <br /> � I I I I I I I II I � <br /> EMER EMERGENCY NIC NOT IN CONTRACT UR URINAL I <br /> ENCL ENCLOSURE OR ENCLOSED NO/# NUMBER � I � <br /> EP ELECTRICAL PANEL NOM NOMINAL VAR VARIES <br /> EWC ELECTRIC WATER COOLER NTS NOT TO SCALE VCT VINYL COMPOSITION TILE FIRE I I I Sheet Title: GENERAL INFORMATION <br /> EPX EPDXY OA OVERALL VERT VERTICAL � <br /> � EQ EQUAL OC ON CENTER VEST VESTIBULE � I I I I I I I I I EXIT I I AND EGRESS PLAN <br /> Q EQPT EQUIPMENT VIN VINYL - - - - - � � <br /> J EST ESTIMATE OD OUTSIDE DIAMEfER/ t- � � EXIT F Date: <br /> � DIMENSION �C VINYL WALL COVERING _ _ _ _ _ _ FIRE _ _ _ _ 05�04�16 <br /> a <br /> EX EXPANSION W WEST Design: <br /> I �— <br /> w EXIST EXISTING OHF OVE HEAD W� WITH FIRE <br /> o EXT EXTERIOR <br /> z OPH OPPOSITE HAND W/0 WITHOUT � I I I I I I I I I I I Drawn: <br /> � OPNG OPENING WC WATER CLOSET <br /> w FA FIRE ALARM WD WOOD I <br /> � FBO FURNISHED BY OTHERS OPP OPPOSITE � <br /> Project No: 15-198 <br /> WF WIDE FLANGE EXIT � <br /> � FCIC FURNISHED BY CONTRACTOR PERP PERPENDICULAR WG WIRE GLASS 1 _ _ _ _ _ _ _ _ H Approved: <br /> �' INSTALLED BY CONTRACTOR PFN PREFINISHED WP WATER PROOF EXIT � FIRE EXIT <br /> � FCTY FACTORY PL PLATE OR PROPERTY LINE WR WATER RESISTANT - � - I- - - - I - I ! - I - - -1--�-- � B u i I d i n g N o: <br /> FD FLOOR DRAIN P LAM PLASTIC LAMINATE � � � � � � N , , , <br /> � WSCT WAINSCOT <br /> � FDN FOUNDATION PLYWD PLYWOOD WT WEIGHT FIRST FLOOR EGRESS PLAN Sheet No: <br /> 0 <br /> °' FE FIRE EXTINGUISHER PNL PANEL <br /> � <br /> FEC FIRE EXTINGUISHER CABINEf PNT PAINT XFMR TRANSFORMER � <br /> � 1"=30'-0" <br /> o FIN FINISH PR PAIR YD YARD COPYRIGHT CRAFT ARCHITECTS 2016 <br />