My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1330 ROCKEFELLER AVE MEDICAL OFFICE BLDG BASE FILE 2018-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
1330
>
MEDICAL OFFICE BLDG BASE FILE
>
1330 ROCKEFELLER AVE MEDICAL OFFICE BLDG BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 12:51:38 PM
Creation date
2/15/2019 8:54:26 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1330
Tenant Name
MEDICAL OFFICE BLDG BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> I ' •-� ,_ <br /> , Mr. Ben Edwards ���' <br /> Map 19� 1988 <br /> Page Two <br /> � <br /> 4. Area and Height Limits For Tvpe II FR <br /> . Floor azea maximum - 39,9U0 SF <br /> . Building height maximum - 12 stories <br /> . Actual building as designed: <br /> . 6 atories plus penthouse <br /> Area Per Floor <br /> . Ground 14�826 <br /> . lst 14,510 <br /> . "Lnd 14�058 <br /> . 3rd 12�286 <br /> . 4th 10�097 <br /> . 5th 9,697 <br /> . Penthouse 4�818 <br /> 5. The building will be fully fire sprinkled. <br /> 6. The building was designed to the followir.g requirements of Chapter 33 <br /> on exits: <br /> . Exit calculations aze as follows using occupant load served divided by <br /> 50 and adding 50 percent of the occupant load of the first adjacent <br /> floor and t5 percent of the occupant load of the story imnzediately <br /> beyond the first adjacent floor. Occupant load is calculated.�s 100 <br /> persons per GSF. <br /> Occ. Exit <br /> Load Cap. Required <br /> Area C.alc. Req• Exit Width Exits as DesiQned <br /> Ground 14,826 148 Z56 5.12 feet 1 stairs � 44" + b' of door <br /> First 14�510 145 246 4.9Z feet 2 stairs @ 44" each <br /> Second 14�058 141 227 4.55 feet 2 stairs @ 44" each <br /> Third 12�286 123 198 3.95 feet 2 stairs a 44" each <br /> Fourth 10�097 101 149 2.99 feet 2 stairs @ 44" each <br /> Fifth 9�697 97 97 1.94 feet 2 stairs @ 44" each <br /> Penthouse 4�818 0 0 3.00 feet 1 stair @ 44" + hatch <br /> All floors meet or exceed the required exit capacities anc', are also designed <br /> to meet the Following additional requirements: <br /> o Ar-angement of exits� if only two exits aze required� shall be placed a <br /> distance apazt equal to and not less than 1/Z the length of the maximum <br /> overall diagonal dimension of the building or area to be served, <br /> measured in a straight line between exits, <br /> 4 <br /> o Distance to Exits -B-Z (MOB) <br /> . With sprinkler system - 200 feet actual maximum not greater than ,� <br /> 100' <br /> o Corridor Width - Minimum of 44 inches is actually 5' wide <br />
The URL can be used to link to this page
Your browser does not support the video tag.