My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1330 ROCKEFELLER AVE MEDICAL OFFICE BLDG BASE FILE 2018-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
1330
>
MEDICAL OFFICE BLDG BASE FILE
>
1330 ROCKEFELLER AVE MEDICAL OFFICE BLDG BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 12:51:38 PM
Creation date
2/15/2019 8:54:26 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1330
Tenant Name
MEDICAL OFFICE BLDG BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> � <br /> . ,.... ,--. <br /> . � Mr. Ben Edwazds <br /> May 19, 1988 <br /> Page Three <br /> o Stair Width - 44 inches <br /> o Fiandrails may project 3-1/2" from each side of stairway stringers and <br /> other projections maq project into required width 1-1/2" on each side. <br /> o Rise/Rum of Stairs - <br /> . Not less than 4 inches nor greater than 7 inches for rise (6-1/2" <br /> actual) <br /> . Not less than 11 inches for treads (11" actual) <br /> o Stairway to Roof - <br /> . Every building 4 or more stories in height; one stairway shall extend <br /> to the roof surface. All other stairs must have a hatch of a <br /> minimum of 16 SF opeaing onto roof. Stair #1 has hatch and atair <br /> �#2 goes to the roof. <br /> o Dead-End Corridars - No more than 20 feet <br /> o Corridor Construction - 1 hour fire resistive <br /> o Enclosure Construction - <br /> . Encloaure walls shall be of not lesa than 2 hour fire reaistive <br /> construction in building of 4 ot more stories in height or of tqpe I ot <br /> type II fire resistive construction. Stairs enclosure walls aze 10" <br /> concrete walls. <br /> 7. The entrq lobby is designed as a vertical shaft. All doors lending into <br /> the shaft aze automatic closing 1-1/2 hour B label with all sepazation <br /> walls surrounding the shaft having a 2 hour rating. Opening in the <br /> exterior wall are per table 5A with fire sutters on the east windows that <br /> aze lesa than 10' form the adjoining building. The atairway in that <br /> enclosure is not a required exit way. <br /> I trust this gives you the in£ormation you require, if not, or if I can be of any <br /> further assistance� please call. <br /> Sincerely, <br /> ' i��"�'"'"' <br /> Dennis Forsyth <br /> Project Manager <br /> 153p <br /> cc: Mr. Mackie Skene <br /> Mr. Scott Greenwood <br /> Mr. Alan Limpo <br />
The URL can be used to link to this page
Your browser does not support the video tag.