i <br /> � <br /> Coffman VFT Engineers . I , �� --�� <br /> Apri125, 198R II Un� �J � � 'il ,� l�' I �J � <br /> u U APR 2 �i 1988 '--� <br /> ................... _ <br /> ciiv o� cv����r� <br /> Mr. Dennis Forsyth Publ�c '�v��is �ept. <br /> The NBBJ Group <br /> 111 South Jackson Street <br /> Seatde,Washington 98104 <br /> Project: Everett Medical Office Building Pazking Lot <br /> Everett,Washington <br /> Subjxt Retaining Wall <br /> Dear Dennis: <br /> At your request,we have invesrigaud the structural integrity of the existing ntaining wall <br /> reladve to the revised usage of the area ie back of the wall (namely, being converted to a <br /> � pazldng lot). <br /> ` As you will recall at the time the bid documents were prepazed,we had not(and still have <br /> not) seen any drawings and/or calculations for the original design of the wall. <br /> Consequendy, we indicated a strengthening method which we envisioned as a worst case <br /> (from both a dme and money point of view)subject to a more thorough investigadon aftor <br /> � contract award. <br /> � On Aprii 5, 1988, Gaffney Construcaon performed an "x-ray" evaluation of the wall <br /> reinforcement, subsequendy confirmed by exploradon through selecdve demolidon. It <br /> would be reasonable to assume that the roinforcement pattem discovaed would bc unifomi <br /> throughout the length of the wall. That reinforcement has proven to be: <br /> No. 5 Bars @ 8" o.c, vertically (flexural) with every other bar terminated 2' 6" from U�e <br /> top of the wall and No. 4 Bars @ 12" o.c. horizontally (temperature/shrinkage). The <br /> physical properties of�tie wall are: approximately 150'0" long; 12-inch thick throughout <br /> its 10' 6" height with 3 1/2-inch square drain holes @ 4' 0" o.c. (note that the drain holes <br /> have been covered by tennis court paving); the reinforcement has been placed on the <br /> tension (backfill) side of the wall with 1 1/2" of cover. A visual inspecdon by Gaffney <br /> Consavcdon has revealed no signs of distress in the wall. A soils invesdgadon performed <br /> before awazd of contract has revealed soils of a very stable and dry nature. <br /> We compared the above informaaon to the properties required by the Concrete Reinforcing <br /> Steel Institute (CRSn handbook(1984 edidon)for canalevered retaining walls using what <br /> we feel to be conservadve criteria(Class "C" soil with sloping backfill). Using this criteria <br /> the flezural steel is well W�ithin guidelines and the wall thiclmess and temperature/shrinkage <br /> steel is marginal; however, the service life and condidon of the wall lead us to conclude that <br /> they aze sadsfactory. Please note that there has been no discussion of the existing wall <br /> footing; to examine the wall foodng would require demoliaon of a portion of the exisdng <br /> tennis courts which aze not the property of this Owner. We believe that it is a sound <br /> �m o�rve vrr•eurte wo•se�me vM uim�ieu•t:oe�ezw�ir <br /> 55a SEVENiN ME•SUIiE 100•ANLMORr1GE AK 9950�•(90])2)6665� <br />