My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10627 19TH AVE SE COOLEY SMILES DENTISTRY 2019-03-18
>
Address Records
>
19TH AVE SE
>
10627
>
COOLEY SMILES DENTISTRY
>
10627 19TH AVE SE COOLEY SMILES DENTISTRY 2019-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2019 8:51:29 AM
Creation date
3/7/2019 4:55:59 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10627
Tenant Name
COOLEY SMILES DENTISTRY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cooley Smiles Dental Clinic 17318.20 October 18,2017 <br /> Drainage Report Section II, Page 2 <br /> Minimum Requirement#1: Preparation of Stormwater Site Plans:The stormwater site plan consists of <br /> this report and the civil drawings, and is prepared in accordance with Chapter 3 of Volume 1 of the <br /> SWMMWW. <br /> Minimum Requirement#2: Construction Stormwater Pollution Prevention Plan (SWPPP):The SWPPP <br /> shall include a narrative and drawings.The SWPPP narrative shall include documentation that addresses <br /> the 13 elements of Construction Stormwater Pollution Prevention. See Section V and the civil drawings. <br /> Minimum Requirement#3:Source Control of Pollution: Source control BMPs during construction are <br /> described in Section IV, which addresses Minimum Requirement#2. It is not anticipated that permanent <br /> source control BMPs will be required as the site does not contain any of the activities listed in Vol IV Ch. <br /> 3-5 of the 2014 SWMMWW. <br /> Minimum Requirement#4: Preservation of Natural Drainage Systems and Outfalls: Natural drainage <br /> patterns shall be maintained, and discharges from the project site shall occur at the natural location,to <br /> the maximum extent practicable.The manner by which runoff is discharged from the project site must <br /> not cause a significant adverse impact to downstream receiving waters and down-gradient properties. <br /> All projects shall submit an off-site qualitative analysis.A qualitative analysis of the upstream and <br /> downstream system entering the site is presented in Section III. <br /> Minimum Requirement#5:On-Site Stormwater Management: Per Table 1-2.5.1 of the 2014 <br /> SWMMWW, redevelopment projects on any parcel inside the Urban Growth Area that trigger Minimum <br /> Requirements#1 through#9 must demonstrate compliance with the Low Impact Development <br /> Performance Standard and BMP T5.13; or use On-Site Stormwater Management BMPs from List#2.This <br /> project will demonstrate compliance with the Low Impact Development Performance Standard. See <br /> Section IV. <br /> Minimum Requirement#6: Runoff Treatment:This requirement applies to the new plus replaced hard <br /> surfaces and the converted vegetation areas.The following projects require construction of stormwater <br /> treatment facilities: <br /> i.) Projects in which the total of pollution-generating hard surface (PGHS) is 5,000 square feet <br /> or more in a threshold discharge area of the project, or <br /> ii.) Projects in which the total of pollution-generating pervious surfaces (PGPS)—not including <br /> permeable pavements is 0.75 acres or more in a threshold discharge area, and from which <br /> there will be a surface discharge in a natural or man-made conveyance system from the site. <br /> This project's total of PGHS is less than 5,000 square feet and runoff treatment is not <br /> required. <br /> The project requires water quality treatment because the total amount of pollution-generating hard <br /> surface (PGHS) is 5,000 square feet or more in a threshold discharge area of the project. See Section IV. <br /> 250 4th Avenue South,Suite 200 <br /> Edmonds,WA 98020 <br /> ENGINEERING ph.425.778.8500 I f.425.778.5536 <br /> www.cgengineering.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.