My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
112 SE EVERETT MALL WAY LOVERS PACKAGE 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
112
>
LOVERS PACKAGE
>
112 SE EVERETT MALL WAY LOVERS PACKAGE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2019 3:50:25 PM
Creation date
3/8/2019 3:46:08 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
112
Tenant Name
LOVERS PACKAGE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, l � <br /> Constntction <br /> 1. Lateral and gravity structural calculations must be provided before a structural review <br /> will begin. <br /> 2. Energy calculations (envelope, lighting& mech.) should be provided. <br /> 3. Safety glazing should be labeled on the elevation drawings for the windows with the <br /> bottom edge less than 60"above the floor and within 24"either edge of a door(in a <br /> closed position). Section 2406.4 <br /> 4. Fire blocking should be shown within the furred walls at the level of the suspended <br /> ceiling. Section 708.2.1 <br /> 5. Details for the lateral bracing and compression swts for the suspended ceiling should <br /> be provided. UBC Standazd 25-2 <br /> 6. Roof venting should be provided at a minimum ratio of 1:150. Calculations and <br /> details should be provided. Venting at beam line B should be clarified. Section <br /> 1505.3 <br /> 7. The slope of the entry sidewalk should not be greater than 1:20. A curb cut should be <br /> provided from the pazking access aisle to the sidewalk. Sections 1106.43 @_ <br /> 1106.4.7.1 <br /> Please prepare a response letter showing where each item in this coaection letter is <br /> addressed on the plan set. <br /> Upon resubmission of the drawings, your application�vill be given priority and plan <br /> review will recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to <br /> ensure that the proposed structure will be constructed in compliance with all adopted <br /> codes. <br /> Sincerely, <br /> � <br /> nv R. Lee <br /> Plans Examiner <br /> �L <br />
The URL can be used to link to this page
Your browser does not support the video tag.