My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10901 27TH AVE SE 2018 Plans 2022-11-30
>
Address Records
>
27TH AVE SE
>
10901
>
Plans
>
10901 27TH AVE SE 2018 Plans 2022-11-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 8:13:41 AM
Creation date
3/12/2019 8:15:47 AM
Metadata
Fields
Template:
Address Document
Street Name
27TH AVE SE
Street Number
10901
Permit
B1803-047
Year
2018
Notes
MONROE ELEM INSTALL 1 NEW PORTABLE AND LANDING AND STAIRS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o � �A P�3 �,5,� co <br /> #5 VIA PC5 GENERAL NOTES: <br /> �,/ � <br /> 1. WHEN STRANDED WIRE IS USED, A�L TERMINATIONS ARE MADE BY <br /> (2) 8' x 4' WHITE BOARDS w/ A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br /> 3 5 7 � OR OTHER APPROVED MEANS OF TERMINATION. <br /> MARKER TRAY (SHIP LOOSE) PCPCPC ELECTRIC <br /> INSTALLED ON SITE BY OTHERS PANEL 2. ALL CONDUCTORS ARE COPPER;TYPE THHN /THWN <br /> t O b t O b � O b 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br /> -- - -- �— - - - - - - - - - - -- -- - - - - - - - - - - - �1 <br /> / � 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE <br /> I <br /> GFCI <br /> I #2,4 5. HVAC DISCONNECTS SHAIL BE LABELED WITH AN IDENTIFICATION <br /> � PLATE SHOWING CIRCUIT NUMBER AND EQUIPMENT SERVED. <br /> � WAC 296-46B-1 10 022 . <br /> � ONE-LINE-DIAGRAM <br /> � 6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A "HEAVY DUTY" 100 AMP FEEDER PANEL <br /> WEATHER PROOF"IN USE"COVER. 2014 NEC 406.9(B)(1) MAIN BREAKER <br /> C - - -. .- — _. —. - - - - - - - -- -- - - - - - - - - - - � -- - --� � -- 120/240 1� <br /> l O b 1 O b 1 O b I I PP 7• CONTROLLED RECEPTACLES SHALL BE �ABELED PER 2014 NEC <br /> 406.3(E) WITH THE TEXT"CONTROLLED"AND THIS SYMBOL � 100 AMP <br /> � - - - - - - - - - - - - - o r — <br /> B <br /> nPP16 POWER 8• THIS PLAN IS NOT AN"AS-BUILT"CIRCUITS MAY BE RUNDIFFERENT <br /> THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. 1/2" PVC 1-1/2" PVC STUB THRU <br /> � PACK TO SIGNAL STUB FOR BY BLAZER <br /> I THERMOSTAT FUTURE (2) #2 Cu THHN <br /> I OCCUPIED PERIOD GROUNDING (1) #4 Cu THHN <br /> � AND (1) #6 Cu <br /> � � (WIRE ON SITE BY OTHERS) <br /> � � � 51-11C WAC 2015 WSEC CHAPTER 4 NOTES: BON�iNc <br /> � a <br /> ,- - - - - - - - - - - - --� -- - - - - - - - - - - - -- � - -- Q <br /> 5 1. ALL LIGHTING SHALL CONFORM TO SECTION C405 <br /> 1 1 <br /> } O a O a O q �k 2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) PANEL SCHEDULE <br /> I 833 SQ. FT.x l WATT PER SQUARE FOOT=833 WATTS ALLOWED <br /> NOTE:ALL CONDUCTORS COPPER. 100 AMP 1� 22,000 AIC <br /> � ADDITIONAL REDUCTION IN LIGHTING POWER DENSITY (C406.3.1) <br /> � 833 WATTS ALLOWED (BASEJ x.75= 625 WATTS ALLOWED CKT DESCRIPTION TRIP WIRE VOLT "IOO VOLT WIRE TRIP DESCRIPTION CKT <br /> NO. AMPS SIZE AMPS A B AMPS SIZE AMPS NO. <br /> I 1 LIGHTS 20 12 552 �� r\ 7052 4 80 HVAC 2 <br /> TOTAL WATTS ALLOWED = 625 _�---� /--� <br /> �� TOTAL WATTS INSTALLED = 477 WATTS 3 RECEPTACLES 20 12 t260 �� �� 7052 / / / 4 <br /> � � %OF ALLOWED INSTALLED - 76% 5 RECEPTACI.ES 20 12 1080 — �PACE 6 <br /> 7 RECEPTACLES 20 12 900 �� �~ — — — SPACE 8 • <br /> O3. 100%OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 9 SPACE — — — �� �� - - - sPacE �o <br /> DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE 11 5PACE - - - �� �� - - - sPac� 12 <br /> INDIVIDUALLY ADDRESSABLE. (C406.4) 13 s�acF - - - �� �\ — — — SPACE 14 <br /> 15 SPACE — — — �� �~ — — — <br /> — SPACE 16 <br /> �4, 100%OF LIGHTING IS SET FOR CONTINUOUS DIMMING AND IS » SPACE — — — �� �� - - - sPACE �8 <br /> ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA 19 SP��cE - �� �\ — — — S�ACE 20 <br /> WALL PODS. (C406.4) <br /> ELE �TRICAL PLAN <br /> 5. 50%OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY E L E C T R ( C A L S Y M B O L S <br /> SENSORS (C405.10� <br /> 1/4" = 1'-0" ARS 9/25/2017 AFF <br /> SYMBOL DESCRIPTION REMARKS <br /> b. THERMOSTAT OCCUPIED PERIOD WIIL BE DETERMINED BY THE TO TOP <br /> nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTWG �px nLIGHT DIMMING CONTROL 48» DIMMING CONTROL. LOWER CASE , <br /> SWITCH CAT5E CONNECTED LETTERS DESIGNATE ZONING <br /> FIXTURES. <br /> H.V.A.C. (MOTOR, COMPRESSOR, HEATER SIZES) PC PLIUG LOAD2CONTROL RELAY CEI�NG FI�TUR�LOCCUPANCIY SEN RSED <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. nLIGHT nPP16 THERMOSTAT ABOVE CONTROLLED BY nLIGHT ENAB�ED <br /> COMPRESSOR 11.8 RLA 83 �RA ELECTRICAL PLAN REVIEW PP CONTROL RELAY CEILING FIXTURE OCCUPANCY SENSORS <br /> OUTDOOR FAN 2.5 FLA 1/5 H.P. LOAD CALCULATIONS <br /> rR DUPLEX RECEPTACLE 180 VA EACH <br /> INDOOR BLOWER FAN 2.8 FLA 1�3 H.P. � HALF CpNTROL�ED HALF HOT 20 TAMPER RESISTANT <br /> HEAT STRIP 10 KVA rR QUADPLEX RECEPTACLE 180 VA EACH <br /> MINIMUM CIRCUIT AMPS 7J AMPS VOLTAGE: 120/240 PHASE: 1� � HALF CONTROLLED HALF HOT 20 TAMPER RESISTANT <br /> MAXIMUM OVERCURRENT PROTECTION $O AMPS NOTE: ALL DEVICES 8c FACE coNNECTE� �oA� CALC. LOAD SINGLE RECESSED CLOCK <br /> OVERCURRENT PROTECTION- DUAL ELEMENT TIME DELAY FUSE PLATES TO BE IVORY � a HANGER RECEPTACLE 84�� 180 VA EACH <br /> OR HACR CIRCUIT BREAKER LIGHTING <br /> EXTERIOR 75 VA x 125 % = 94 VA �Fci W�ATHER RESISTANT GFCI . <br /> RECEPTACLE 20" 180 VA EACH <br /> INTERIOR 477 VA x 125 % = 596 VA PHONE / DATA BOX 20�� 4" SQ BOX SWGLE GANG MR WITH <br /> QTY. SIZE DESCRIPTION � <br /> 3/4" CONDUIT UP AND DOWN <br /> ELECTRICAL PANEL � 100 120/240V - SINGLE PHASE - STUB THRU - METALLIC RACEWAY SYSTEM RECEPTACLES � FIRE ALARM PULL STATION 48" <br /> THRU 10,000 3240 VA x 100 % = 3240 VA 4" SQUARE BOX w/ SINGLE GANG MUD <br /> 9 2 x 4 L�ED VOLUMETRIC TROFFER— nLIGHT ENABLED— 6000 LUMEN— 53 WATTS— 4000K FIRE ALARM INTERIOR RING — 3/4" RACEWAY STUB UP ONLY <br /> WITH EMBEDDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATING ON CAT5E � HORN / STROBE 84 PAINT BOX, MUDRING AND RACEWAY <br /> LIGHTING LOCAL NETWORK LITHONIA — BLT460LADPEZ1LP840N100NES7ADCX OVER�o,000 0 VA x 50 % = 0 VA "RED" IN COLOR <br /> MOTORS, COMPR. FIRE ALARM EXTERIOR <br /> � HORN / STROBE 84 <br /> 1 72 WATT LED WALL PACK w/ INTEGRAL PHOTOCELL ECONOLIGHT E-WP11 L07CZ / E-ACP1 TOTAL 4104 vA x 100 % = 4104 VA <br /> O THERMOSTAT 48» 4�� SQ BOX SINGLE GANG MR WITH <br /> HVAC 1 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ 1NTEGRAL ERV— 11 EER RATED LARGEST (2832) VA x 25 % = 708 VA 1/2" CONDUIT STUB UP <br /> HEATING 1000o va x 100 / = 10000 va � <br /> THERMOSTAT � BARD 8403-060 w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE AUTOMATIC SETBACK— � LED WALL PACK 84" 75 VA EACH <br /> DEADBAND CONTROL — OCCUPANCY INTEGRATED �NTO nI.IGHT SYSTEM <br /> 1 BARD CMC-29 FREEZE STAT O nLIGHT ENABLED LED TROFFER <br /> TOTAL KVA �7.90 TOTAL KVA 18.74 � w/ INTEGRAL SENSORS CEILING 53 VA EACH <br /> CO2 SENSOR � BARD 8403-067 - DEMAND CONTROL VENTILATION CONNECTE� CAICULATED , <br /> LOAD AMPS 74.57 LOAD AMPS 78.pg 8 ELECTRICAL PANE� 72" <br /> 7-17-17 ELECTRICAL ENGINEERING ARS COPYFiIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: Job No: 19031 <br /> 9-25-17 REDUCED PANEL SIZE TO 100 AMP i ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY Classroom for. <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ 2$ X 32 KC DA - Eve rett S�D■ File Copy: <br /> NOT BE REPRODUCED, USED,OR DISCLOSED <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,�Nc. Drawn ey: LDG � <br /> i� www.blazerind.com wA. GOLD Pacific Mobile 17 BLMP-04 A9 WA <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZEFi INDUSTRIES. �� p.p.BOX 489 t Aumsvil�e,OR 97325-0489 ISSU2 DBte: 9-ZJ�-17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.