My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7100 HARDESON RD 2019-03-22
>
Address Records
>
HARDESON RD
>
7100
>
7100 HARDESON RD 2019-03-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2019 12:28:00 PM
Creation date
3/22/2019 12:27:51 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
641 L e <br /> � '- <br /> 1601 <br /> 1601 Fifth Avenue,Suite 1300,Seattle,WA 98101 1206-382-0600 I kpff.com lgiff <br /> January 25, 2017 <br /> 11-E- n <br /> Meg Haley <br /> City of Everett Permit Services <br /> 3200 Cedar Street JAN N 3 0 2017 <br /> Everett,WA 98201 <br /> CITY OF EVERETT <br /> Permit Services <br /> Re:Permit#81701-003 Non-structural plan review corrections—Mechanical compliance <br /> Dear Meg, <br /> The scope of this mechanical permit application includes installing one roof-mounted downblast ventilator <br /> (exhaust fan)to exhaust air from two below-grade inspection pits. 2015 IFC 2311.4.3 states that for repair <br /> garages where Class I liquids are stored within a building having a pit wherein flammable vapors could <br /> accumulate,the pit shall be provided with a minimum rate of 1.5 cfm/sqft mechanical ventilation. This flow rate <br /> supersedes those required by IBC, IMC,and NFPA 30A. <br /> The existing ventilation ducts supply air into the inspection pit. This purpose of this project is to connect the <br /> existing ductwork to a new exhaust fan to provide adequate exhaust flow. <br /> Demolition: <br /> Remove ductwork connecting existing inspection pit ventilation ducts to the building supply air. Ceiling/roofing <br /> penetration is required to install an approximately 2'square curb to mount the exhaust fan. <br /> Construction: <br /> Install new roof mounted exhaust fan and curb,then connect existing inspection pit ductwork to exhaust fan. <br /> Code requirements: <br /> 1. 2015 IBC Table 307.1(1), hazardous material limits <br /> Class Stored (gal.) Allowed (gal.) Comment <br /> IB gasoline 56 120 OK <br /> IC paint <br /> II diesel, paint thinner 255 360 OK,307.1(1) notes d &e applied <br /> IIIB lube/motor/waste/hyd oil,atf 2500 13200 OK <br /> 2. 2015 IFC 2311.4.3 <br /> Provide minimum of 2430 cfm to two inspection pits,see enclosed exhaust fan design load calculations. <br /> 3. WSEC energy code compliance <br /> Completed 2015 WSEC compliance form and relevant spec/plan enclosed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.