Laserfiche WebLink
Rrar\r-N,F--zn\kfir-E, 0 <br /> MAY -9 2018 <br /> CITY OF EVERETT <br /> �� Permit Services <br /> MN <br /> enGinEeRs <br /> Washington <br /> Oregon <br /> on <br /> California <br /> Texas <br /> (1) <br /> (1) May 9,2018 <br /> Alaska <br /> Tit <br /> Colorado <br /> ' Montana City of Everett <br /> Attn: Drew Martin <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> Re: Structural Plan Review <br /> 1502 Hewitt Avenue <br /> Plan check Number B1801-036, First Review <br /> Dear Mr. Martin <br /> The following is our responses to your structural comments for the referenced project in your letter dated <br /> February 23,2018. <br /> Structural <br /> 1. The structural drawings do not include structural notes. The structural drawings should specify <br /> the 2015 International Building Code and the 2015 International Existing Building Code as the <br /> governing codes for the design. The drawings should specify design loads and other <br /> information pertinent to the structural design per IBC Section 1603.1. Geotechnical information <br /> should be specified per iBC Section 1603.1.6. <br /> DCI Response: Structural General Notes have been added to the drawings. See sheets <br /> G1.1 and G1.2. <br /> 2. The structural drawings do not include material requirements for the structural systems. <br /> Material properties, connection requirements, fabrication and coating requirements, and other <br /> information required to perform the structural work should be specified in accordance with the <br /> following: <br /> a. Concrete:iBC Sections 1901.5. <br /> b. Masonry:IBC Section 2101.2 and ACi 530-13 Section 1.2. <br /> C. Steel:IBC Section 2205.1,AiSC 360-10 Section A4, and AISC 303-10 Section 3.1. <br /> d. Wood:IBC Section 2306.1 and NDS-15. <br /> DCI Response: The added structural general notes include the required material <br /> properties for the new construction materials in this project. <br /> 3, Structural and geotechnical special inspections are required for this project.A statement on <br /> special inspections shall be submitted with the permit documents. The statement shall include <br /> a table listing each type of special inspection and shall specify the extent of each inspection <br /> (e.g., continuous,periodic)per IBC Section 1704.3.1. The table shall include special <br /> requirements for seismic and wind resisting systems as required by IBC Sections 1704.3.2 <br /> and 1704.3.3, respectively. See iBC Sections 107.1, 1704.2.3 and 1704.3. <br /> 1/b <br /> 818 Stewart Street,Suite 1000,Seattle,Washington,98101 Phone(206)332-1900 <br /> Service Innovation Value <br />