PLUMB NG FIXTURE SCHEDULE
<br /> �
<br /> REMOVE (E) WASH SERVICE PIPE SIZE BASIS OF DESIGN
<br /> FO U NTAI N MARK ITEM IXCALL/0 TIN FLOW RATE REMARKS NOTES
<br /> WASTE VENT C.W. H.W. MANUFACTURER MODEL
<br /> P-1 LAVATORY—UNDER COUNTER L-1 — 2 1-1/2 — — AMERICAN STANDARD OVALYN 0496.221 19x16 OVAL, UNDER COUNTER MOUNTING, VITREOUS CHINA, W/ GRID DRAIN. A, aa
<br /> FAUCET LF-1 0.5 GPM — — 1/2 1/2 SLOAN OPTIMA EfF-80 DECK MOUNTED, IR FAUCET, 4° O.C., RIGID SPOUT, PROVIDE W/ 24 VAC TRANSFORMER.
<br /> MIXING VALVE MV-1 0.5 GPM — — 1/2 1/2 CHICAGO 242.165.00.1 CONCEALED MECHANICAL MIXING VALVE W/ 1/2" TEMPERED WATER LINE FROM OUTLET
<br /> TO FAUCET.
<br /> ' P-2 URINAL—WALL HUNG U-1 1.0 GPF 2 1-1/2 — — AMERICAN STANDARD LYNBROOK 1.0 VITREOUS CHINA, LOW CONSUMPTION, BLOWOUT, BACK OUTLET, 1-1/4" INLET SPUD. 1
<br /> � FLUSH VALVE FV-2 1.0 GPF — — 3/4 — SLOAN ROYAL OPTIMA 180-1.0 ES—S 1.0 GPF, W/ EL-154 120 VAC/24 VAC TRANSFORMER.
<br /> FLOOR FLOOR P-2.1 URINAL—WALL HUNG—ADA U-1 1.0 GPF 2 1-1/2 — — AMERICAN STANDARD WASHBROOK 6590.001 VITREOUS CHINA, HIGH EFFICIENCY, WASHOUT, BACK OUT�ET, 3/4" TOP SPUD. RIM �
<br /> HEIGHT TO BE 17" OR LESS FOR ADA COMPLIANCE.
<br /> FLUSH VALVE FV-2 1.0 GPF — — 3/4 — SLOAN ROYAL OPTIMA 180-1.0 ES—S 1.0 GPF, W/ EL-154 120 VAC/24 VAC TRANSFORMER. '
<br /> CW&HW ���_ � (E)1 -1/2" VENT (VERIFY)
<br /> P-3 WATER CLOSET—WALL HUNG WC-1 1.6 GPF 4 2 — — AMERICAN STANDARD AFWAL� 2856.128 VITREOUS CHINA, ELONGATED BOWI., SIPHON JET, BACK OUTLET, 1-1/2" TOP SPUD. 1
<br /> �----� �E�2�� WASTE (VERIFY) FLUSH VALVE FV-1 1.6 GPF — — 1 — SLOAN ROYAL OPTIMA 111-1.6 ES—S TMO 1.6 GPF, W/ COURTESY FLUSN & EL-154 120 VAC/24 VAC TR,4NSFORMER. '
<br /> � � SEAT TS-1 — — — — — BEMIS 1655SSCT OPEN FRONT, LESS COVER, ELONGATED, PLASTIC, SELF—SUSTAINING CHECK HINGES.
<br /> � P-3.1 WATER CLOSET—WALL HUNG—ADA WC-1 1.6 GPF 4 2 — — AMERICAN STANDARD AFWALL 2856.128 VITREOUS CHINA, ELONGATED BOWL, SIPHON JET, BACK OUTLET, 1-1/2" TOP SPUD. 1
<br /> P—TRAP REMOVE (E) WASTE & (E) VENT TO
<br /> AN APPROPRIATE LOCATION FOR FLUSH VALVE FV-1 1.6 GPF — — 1 — SLOAN ROYAL OPTIMA 111-1.6 ES—S TMO 1.6 GPF, W/ COURTESY FLUSH & EL-154 120 VAC/24 VAC TRANSFORMER.
<br /> RECONNECTION. SEE INSTALLATION SEAT TS-2 — — — — — BEMIS 1655SSCT OPEN FRONT, LESS COVER, ELONGATED, PLASTIC, SELF—SUSTAINING CHECK HINGES.
<br /> DETAIL
<br /> P-4 SEMI—CIRCUtAR WASH BASIN 1.0 GPM 2 1-1/2 1/2 1/2 BRADLEY TERREON WF2504—A—STD—CLC—IRP—TMA 54" SEMI CIRCULAR, INFRARED SENSOR CONTROLS, 12V SOLENOID ACTIVATION, TERREON �
<br /> MATERIAL CONSTRUCTION, THERMOSTATIC MIXING VALVE. 1 GPM FLOW PER SECTION.
<br /> WASH FOU �ITAIN REMO�A� DETAI � �� .
<br /> SCALE: NTS M2-1
<br /> �
<br /> P-5 CIRCULAR WASH BASIN 1.0 GPM 2 1-1/2 1/2 1/2 BRADLEY TERREON WF2508—A—STD—CLC—IRP—TMA 54° CIRCULAR, INFRARED SENSOR CONTROLS, 12V SOLENOID ACTIVATION, TERREON �
<br /> MATERIAL CONSTRUCTION, THERMOSTATIC MIXING VALVE. 1 GPM FLOW PER SECTION.
<br /> �
<br /> 1. COORDINATE MOUNTING HEIGHT W/ ARCH'L INTERIOR ELEVATIONS. A. LAVATORY GRID TYPE (ADA) "DEARBORN" 760W aa. 1-1/4"x1-1/2" 17GA., "MCGUIRE" C8872
<br /> P �UMB NG SYSTEM MATERIA�S AND METHODS
<br /> PIPE SYSTEM SYSTEM PIPE SIZE MATERIAL JOINING METHODS VALVES & ACCESSORIES INSULATION REQUIREMENT
<br /> � ABBREV. RANGE
<br /> BRONZE OR BRASS BODY, CW: 1-1/2"
<br /> S 2" SOLDERED, PROPRESS STAINLESS STEEL TRIM
<br /> DOMESTIC COLD WATER, HOT WATER, DCW, DHW, TYPE L COPPER HW: IF
<br /> HOT WATER CIRCULATING DHWC �2_1/2„ WELDED, FLANGED, GROOVED FITTINGS W/ HIGH BRONZE, BRASS, OR CAST IRON BODY, PIPE S 1.5 , THEN 1-1/2
<br /> „ »
<br /> TEMP GASKETS, VICTAULIC NSF 61 OR EQUAL CHROME PLATED TRIM IF PIPE >—2", THEN 2"
<br /> NEW SEMI—CIRCULAR 1 4 BEND AS HIGH AS cw: �-�/2"
<br /> WASH FOUNTAIN / �� BRONZE OR BRASS BODY,
<br /> S 2 SOLDERED, PROPRESS STAINLESS STEEL TRIM
<br /> POSSIBLE IN WALL INDUSTRIAL COLD WATER, HOT WATER, ICW, IHW, TYPE L COPPER HW: IF
<br /> HOT WATER CIRCULATING IHWC �2_1/2 WELDED, FLANGED, GROOVED FITTINGS W/ HIGH BRONZE, BRASS, OR CAST IRON BODY, PIPE S 1.5", THEN 1-1/2" �
<br /> !�� TEMP GASKETS, VICTAULIC NSF 61 OR EQUAL CHROME PLATED TRIM IF PIPE >—2„ THEN 2,�
<br /> DOMESTIC COLD WATER BELOW FOUNDATION DCW — DUCTILE IRON MECHANICAL JOINTS — —
<br /> � II DOMESTIC COLD WATER BELOW GRADE DCW — TYPE K COPPER BRAZED — _
<br /> �) 1/8 BEND EMERGENCY SHOWER & EYEWASH WATER ESE — TYPE L COPPER SOLDERED, PROPRESS BRONZE OR BRASS BODY, 1-1/2"
<br /> �� STAINLESS STEEL TRIM
<br /> �( LOW WALL PROCESS VENT (BELOW GRADE) PV ALL SIZES 316 SSTL, BLUCHER PASSIVATED, SOCKET WELDED W/ GASKET REMOVED TRANSITION BETWEEN DISSIMILAR _
<br /> P—TRAP �� MATERIALS W/ COUPLINGS
<br /> � VENT TRANSITION BETWEEN DISSIMILAR
<br /> DRAIN �� PROCESS VENT (ABOVE GRADE) PV ALL SIZES 316 SSTL, BLUCHER PASSNATED, SOCKET WELDED W/ GASKET REMOVED MATERIALS W/ COUPLINGS .
<br /> CLEANOUT — —� � I PROCESS WASTE (BELOW GRADE) PW ALL SIZES 316 SSTL, BLUCHER PASIVATED, SOCKET WELDED W/ GASKET REMOVED N/A —
<br /> FLOOR �_�� j FLOOR PROCESS WASTE (ABOVE GRADE) PW ALL SIZES 316 SSTL, BLUCHER SOCKET/PUSH FIT N/A —
<br /> I I SANITARY VENT (BELOW GRADE) V ALL SIZES SERVICE WEIGHT CAST IRON HUB & SPIGOT N/A —
<br /> _ _ � - - - - - - � (E)VENT SANITARY VENT (ABOVE GRADE) V ALL SIZES SERVICE WEIGHT CAST IRON NO HUB N/A —
<br /> � USE (E) FLOOR SANITARY WA ST E B E L O W G R A D E W ALL SIZES SERVICE WEIGHT C A ST IR O N H U B & S P I G O T N/A —
<br /> PENETRATIONS SANITARY WASTE (ABOVE GRADE) W ALL SIZES SERVICE WEIGHT CAST IRON NUB & SPIGOT N/A —
<br /> WHERE POSSIBLE TRAP PRIMER PIPING — GENERAL TP 1/2" PEX TUBING CRIMP RINGS N/A —
<br /> (E)WASTE TRAP PRIMER PIPING — C.I.P. SKID DRAIN TP 1/2" 304 STAINLESS STEEL TUBING WELDED N/A —
<br /> LONG TURN PIPE INSULATION (INSIDE BUILDING) UNLESS OWENS CORNING FIBERGLASS WITH "EVOLUTION PVC COVERS FOR FITTINGS AND
<br /> 1/4 BEND NOTED OTHERWISE ON PLAN OR SPECIFICATIONS PAPER—FREE ASJ" REMOVABLE COVERS FOR VALVES
<br /> WASH FOU �ITA f� IS �A�1D �E�1T DETAI ��
<br /> � SCALE: NTS
<br /> M2-1
<br /> �
<br /> 1
<br /> W5741115
<br /> OFFMAN
<br /> ' PHASE 1 RENOVATION PACKAGE N G I N E E R S
<br /> 1101 2nd,Suite 400�Seattle,WA 98101
<br /> I FC S U B M ITTAL ph 206.623.0717�fax 206.624.3775
<br /> 07.02.18 coffman.com
<br /> LASTING creativity�resNts�relationships
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> yy . J�j��� ACCEPTABILITY COFFMAN 05.25.18
<br /> ORIG WORKPLACE ENVIRONMENT INVESTMENT W5741115 CEI PJ 07.02.18 �� oF W�S� "►' THIS DESIGN AND/OR CHECKED MECHANICAL SCHEDULES AND DETAILS W5741115 O R G 07.02.18
<br /> ��''ti�' I�'G��c� SPECIFICATION IS APPROVED PNGIN�ERS 05.25.18 sHE�r
<br /> BOE���� TITLE WORKPLACE ENVIRONMENT INVESTMENT .
<br /> � APPROVED BY DEPT. DATE COFFMAN 05.25.18 M 2 1 M 4
<br /> CHECKED
<br /> �0 21481 � APPRo�Eo B U I LD i N G 40'S ITE �oB No. W5741115 cornP r,a
<br /> � �0�, REGI STERE� �C'
<br /> �
<br /> �ssroNaL ��� APPRovE° MECHANICAL MASTER EVERETT, I�Iq °wc No. 40—SITE—M2-1