My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-37 Plans 2022-12-05
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-37
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-37 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 1:23:55 PM
Creation date
4/1/2019 11:42:55 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-37
Permit
B1807-041
Year
2018
Notes
ACCESS DEMO AND REPLACE WALLS MINOR RECONFIGURE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONSTRUCT ON �IOTES GEf� ERA� �IOTES <br /> � RETROFIT FLUORESCENT FIXTURE PER DETAIL 3 ON � MOUNT FIXTURE AT 10'-0" ABOVE FINISHED FLOOR. <br /> � � DRAWING 40-037-E500. <br /> 2� SURFACE MOUNTED FIXTURE. <br /> � PROVIDE NEW WALL MOUNTED LED FIXTURE OVER ' <br /> MIRROR. � RECESSED FIXTURE <br /> TO PANEL <br /> X3V37-02C14ELP2 3� PROVIDE NEW RECESSED LED FIXTURE. � LIGHT ASSEMBLIES WITH EMERGENCY FIXTURE SHALL <br /> TO PANEL HAVE BOTTOM FIXTURE CONNECTED TO EMERGENCY <br /> TO PANEL 3V37-02C14LP2 4� PROVIDE NEW SWITCH. CIRCUIT. <br /> 3V37-02C14LP2 MATCH LINE � PROVIDE LED DOWNLIGHT. � MOUNT FIXTURE AT 14'-0" ABOVE FINISHED FLOOR. <br /> SEF SHT. 1 E12 <br /> � I , � CONNECT TO EXISTING CIRCUIT 1 a. 6. CONDUIT: 1�2" MINIMUM. <br /> E O 5 <br /> 1 � 7� PROVIDE SWITCH TO CONTROL SHOWER LIGHTS. 7. CONDUCTORS SHOWN: �10 AWG, STRANDED COPPER, � <br /> NEL % ` H 6 9b 9b <br /> X3V37- 14�LP2 � 70 1 a F3 ! , o � CONNECT TO EXISTING EMERGENCY CIRCUIT 5c. NO ED.TION TYPE THHN/THWN, UNLESS OTHERWISE <br /> \`�,� F8 � FS w 68 <br /> 1 0 4 EA. �� 180 4 EA. i ' <br /> 2 , Oa,22b,24c 22b,22b,24c,20a 9� PROVIDE UL 924 RELAY (FLUSH MOUNT 8. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br /> I � 9b ' 9b 9 ENCLOSURE) TO AUTOMATICALLY TURN ON THE WHICH DO NOT APPROPRIATELY COLORED INSULATION <br /> EMERGENCY LIGHTS IN THE EVENT OF A POWER WITH COLOR TAPE WHEREVER CONDUCTORS ARE <br /> �� 1 a �i ' � � i FAILURE. ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS <br /> ( 4 F9 � '� E ' 24o IN ACCORDANCE WITH THE LATEST NEC (USING TAPE). <br /> �� 180 1 EA. � <br /> E ' 9b 5c �i ' 9 COLOR CODE AS FOLLOWS: <br /> �� <br /> � Fs E Y 120V 480Y 277V <br /> �so 3 EA. 5c � � 9b � 208 <br /> � � <br /> � <br /> � � 20a, b,24c EXP A� (LEFT BUS IN PNL) BLACK BROWN <br /> � 9b �9 � B� (CENTER BUS IN PNL) RED ORANGE <br /> � � I � o <br /> � � - <br /> � � � � � ' C� (RIGHT BUS IN PNL) BLUE YELLOW <br /> F8 10b -- �' � a NEUTRAL WHITE GRAY <br /> I �$0 4 EA. 18s� � EA� � x2 � w EQUIPMENT GROUND GREEN GREEN <br /> F9 1 EA. 20a,20a,22b,24c �80 3 EA. ' `�� g 20 1 1 1 ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> 180 F$ <br /> 10b 20a,22b,24c 10b *GREEN WITH YELLOW TRACER <br /> I �ao 3 EA, 4 TYP I �1 <br /> 10b 20a,22b,24c EXP � a ( � �E G E D <br /> 4 5 9. SWITCH LEG COLOR: YELLOW/BLACK <br /> E E E 8 � " 5c � � D2 SURFACE MOUNT LED 5" DIAMETER DOWNLIGHT. <br /> � � D2 10 MOUNTS IN J-BOX. 1000 LUMENS, 3500K, 10. THREE-WAY AND FOUR-WAY SWITCH TRAVELERS: <br /> _- <br /> a _ COOPER HALO SLD612-8-35-WH-UNV-JB <br /> - ---- -- - <br /> 7 10 ORANGE BLACK <br /> —�/ 10b � � b �—/// E5c i ' a � 1 E 1 � F14 WALL MOUNT LUMINAIRE, Al2 ACRYLIC BLUE/BLACK <br /> �so 4 EA. EXP E E E a � � 14 WRAPAROUND LENS; 1 LAMP T8 WITH BALLAST 11 . LIGHT FIXTURE LOCATIONS ARE APPROXIMATE AND <br /> H16 H16 24c,24c,20a,22b 5� 5c D2 1 1 REMOVED. FOR USE WITH 4100K, 14W LED 4 T8 > » <br /> I70 �� X2 , — <br /> 5 5 �0 1 a <br /> � ,�, 3 a 1 E SYLVANIA �LED14T8/L48/FG/841/BF • <br /> � VERTICAL PA T g p �2 � 12. MOUNT SWITCHES AT A HEIGHT OF 54" ABOVE FINISHED <br /> ww 5 <br /> BOOTH CABI T 1 a 5c 1 10 � R13 3" RECESSED LINEAR LUMINAIRE. SATINE LENS FLOOR UNLESS OTHERWISE NOTED. <br /> a 14 1 LAMP T8 WITH BALLAST REMOVED. FOR USE <br /> z = i Ei E540 � " 2 � WITH 4100K, 14W LED 4' T8 REPLACEMENT LAMP. 13.REFERENCE DRAWING E509 FOR FIXTURE SCHEDULE. <br /> "' 3 ACUITY MARK LIGHTING PART N0. <br /> Q � F 1 14 � SL4F-4-GB-1 -T8-REMOVE BALLAST-277-FA 14. REFERENCE DRAWING E510 THROUGH E522 FOR <br /> � �� 6 5c 4 � 5c 4 1 SYLVANIA LED14T8/L48/FG/841/BF EMBEDDED CONDUIT PLAN. <br /> I 1a 6 # <br /> � E � � 15• LOCA IIONT FLOOR SHALL NOT BE DRILL NY <br /> I D2 <br /> 3 - , G a 1 a 10 16.CONDUIT IN CLASSIFIED AREAS SHALL BE EXPOSED OR <br /> - - - — — W 1 1 1 0 0 � � EMBEDDED IN CONCRETE, WHERE APPLICABLE ROUTING <br /> '�' 5c SHALL BE RESTRICTED TO THE TOP SECTIONS OF THE <br /> 9 - <br /> 3 o ROOMS WITH VERTICAL DROPS TO UTILIZATION DEVICES. <br /> � m � m m � m � � o I CHASE 1a 1 1 1 <br /> o E 17. CONDUIT IN OFFICES, LUNCH ROOMS, RESTROOMS AND <br /> 2 _ SIMILAR AREA SHALL BE CONCEALED INSIDE WALLS OR <br /> TYP ABOVE CEILINGS. <br /> � = m <br /> � � � 18.CONDUIT SHALL NOT BE INSTALLED IN LOCATIONS <br /> � <br /> = 5c 9 � 5c ! SUBJECT TO IMPACT OR DAMAGE DUE TO NORMAL <br /> I 4 w 3 ACTIVITIES IN THE AREA. <br /> = CORRIDOR 2 1 1 <br /> E D2 1 1 19. CONDUITS 1 -1/2" AND BELOW IN ALL AREAS BETWEEN <br /> 1 a � COLUMNS 'C' AND 'D' EXCEPT IN ROOM 124 SHALL BE <br /> 1 4 � ELECTRICAL METAL�IC TUBING (EMT). ALL EMBEDDED <br /> - ; - '� 1 CONDUIT AND CONDUIT WITHIN HAZARDOUS AREAS <br /> --��---- SHALL BE RIGID GALVANIZED STEEL RGS CONDUIT. <br /> 1a � <br /> 2 5c o I 20 UL 924 RELAY IN A NEMA 1 ENCLOSURE PER DETAIL 2 <br /> I ON DRAWING 40-037-E500. <br /> � w � 20 � o 0 <br /> I �a 7 � R A B C D <br /> = 5c 9 <br /> 14 <br /> T T 3 ° � D � D2 1 1 � <br /> �� +48„ �� , �Q 1 E10 1 E11 1 E12 13 <br /> +48" a 1 —� <br /> m � $� � m � MATCH LINE m a 1 a �� � 1 1 1 <br /> � — — _ � � 1E13 1E14 �1E15 12 <br /> SEE SHT. 1 E18 � <br /> . 1E122 <br /> T � 14 2 1E16 1E17 1E18 <br /> -TO PANEL 11' <br /> SUPPORT FIXTURE 70 <br /> ON "UNISTRUT" CHANNELS. 3V37-02C10LP4 1 E19 1 E120 1 E121 <br /> CKT. 1 a �o' <br /> P �AI� �I EW BUILDING 40-37 <br /> SCALE: 1/8"=� '-o" N KEY PLAN <br /> OFFMAN <br /> W5741115 N <br /> N G I N E E R S PHASE 1 RENOVATION PACKAGE SCALE: NONE <br /> 8' 4' 0 4' 8' 1 6' <br /> 1101 2nd Ave.,Suite 400�Seattle,WA 98101 IFC SUBMITTAL <br /> `n <br /> ph 206.623.0717�fax 206.624.3775 <br /> coffman.com 07.02.�8 a � n � <br /> LASTING creativity�results�relationships SCALE: 1/8 -1 -0 <br /> ac <br /> � <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE `� <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE �V � J�N�� ACCEPTABILITY D. MELLNICK 03.02.92 W5741115 � 07.02.� 8 K <br /> v �� „ ��� FIRST FLOOR LIGHTING PLAN <br /> � f THIS DESIGN AND�OR CHECKED � <br /> A RECORD DWG — LOCKWOOD GREENE 03.01.94 F RESTROOM RENOVATION � D13 W5741115 CEI PWJ 07.02.18 �`' � ��� r� SPECIFICATION IS APPROVED D. ROBINSON 03.02.92 SHEET a <br /> B ADD LIGHT & SWITCH AT SCHEDULING TABLE 91297-04 DLH REL 04.24.95 �,�� � r `°`i f- � APPROVED BY DEPT. DATE qH gRED ON 03.02.92 TITLE WORKPLACE ENVIRONMENT INVESTMENT 1 E 15 E 14 � <br /> BO � <br /> C REPLACED SINGLE WITH DUAL SWITCH 91431-03 DLH REL 05.02.95 c c _ <br /> A. BREWTON 11.19.92 B U I L D I N G 40 37 <br /> APPROVED JOB N0. COMP N0. _ <br /> � t- ��j - ti� A. BREWTON 11.19.92 10296292 � <br /> D LIGHT TIMER INSTALLATION 10296292 BDH TT/FB 08.12.10 0 , r <br /> �f,� =l,ti'1'T.������' APPROVED <br /> E 40-37 HLFC AND RECORD SET 10854589 SAZAN/FW 12.01.13 owc No. <br /> W.C. HARRISON 11.19.s2 ELECTRICAL MASTER COL. C-D/12-13 EVERETT, WA 40-037-1 E15 <br /> 6/2712018 <br />