�EGEf� D <br /> E � RECEPTACLE IN FLOOR BOX <br /> C D GFCI <br /> , <br /> 1/2"C, (6) �14 TO MCB-26 <br /> VIA PULL BOX AND CONDUIT F30 <br /> E 1 . REFERENCE DRAWINGS E510 THROUGH E522 FOR <br /> . <br /> EMBEDDED CONDUIT. DO NOT INSTALL EMBEDDED <br /> CONDUIT FROM THIS DRAWING. <br /> #14 TO PANEL „ <br /> 2V37-02C14RP 2. ALL CONDUIT 3/4 UNLESS NOTED OTHERWISE. <br /> CKTS. 37a,39b 41 c �7 <br /> ' ��4 MATCH LINE 3. ALL WIRING TO BE #10 AWG STRANDED COPPER WITH . <br /> THHN INSULATION. <br /> `��� 16EXP . 14 �i � ',����E62;� 4. REFERENCE DRAWING EO FOR NOTES, SYMBOLS AND <br /> � � #14 <br /> � � � E COLOR CODE. <br /> � % � i 4a _ �_—� <br /> � 39b 5. THE FIRST FLOOR SHALL NOT BE CORE DRILLED AT ANY . <br /> � C� 13a � 2V37-02C13RP16 <br /> i ��., � C KT. 13a LOCATIO N. <br /> � �� � � XP 6. EMBEDDED CONDUIT SHALL BE 1 ". RIGID GALVANIZED <br /> � � � � � � <br /> XP 14 � � �� STEEL (RSG). <br /> .�c 18c EXP � ��„ 7. CONDUIT IN CLASSIFIED AREAS SHALL BE EXPOSED, <br /> TO PANEL � ►�1 � -��F,; ROUTING SHALL BE RESTRICTED TO THE TOP SECTIONS <br /> 2V37-02C14RP2 \/ � _;�; ,,, <br /> � 1 c ( -�-�, OF ROOMS WITH VERTICAL DROPS TO UTILIZATION <br /> CKTS. 14a,16b,18c I a 6b EXP DEVICES. <br /> —� �i� <br /> �� P EXP �O � � , 8. CONDUIT IN OFFICES LUNCH ROOMS RESTROOMS AND <br /> ,�—_j �� I— �' � SIMILAR AREAS SHALL BE CONCEALED INSIDE WALLS OR ' <br /> � �--� � <br /> � ----�� �� EXP 16b �� <br /> ! ABOVE CEILINGS WHENEVER POSSIBLE. <br /> 6 � <br /> � � � �� 3���,7a ' <br /> � � � �� <br /> �-- --, 18c EXP _ <br /> � 0 0 � , ���� __ _ �� EXP � 9. CONDUIT SHALL NOT BE INSTALLED IN LOCATIONS <br /> � ' -- I -_-- SUBJECT TO IMPACT OR DAMAGE DUE TO NORMAL <br /> ' � � ; \ _.__�__ _ ACTIVITI ES I N TH E AR EA. <br /> � � ` %" � <br /> �'` � 10. ALL CONDUIT 11 2" AND BELOW BETWEEN COLUMNS "C" <br /> � � �` � � » » � <br /> � 16b / � 18c METDALLDIC TUBENG (EMRj OM 124 SHALL BE ELECTRICAL <br /> EXP -��— 14a EXP � 16b � <br /> ----_ - , X � 37 <br /> EX ;; � 11 , ALL CONDUIT IN ROOM 124 AND OTHER AREAS , <br /> CLASSIFIED AS HAZARDOUS SHALL BE RIGID GALVANIZED <br /> � STEEL (RGS). <br /> 18c EXP ` 14a EXP ' <br /> 10 #14 TO MCB-26 12 50VA 120/24VAC TRANSFORMER PER DETAIL 1 ON <br /> 8 12 3 � VIA 1 "C � DRAWING 40-037-E500. <br /> � ; O 13 1/2"-2�16 TO 50VA TRANSFORMER. <br /> � � 13 SENSOR FAUCET <br /> I 2V37-02C 13RP 16-1/28b,30c 41 c � � 120V (TYP OF 3) a � C 0 �l S T R U C T I 0 �l �l O T E S <br /> 4�10 W/ 1#10GND #14 � PROVIDE NEW RECEPTACLE, CIRCUIT AS SHOWN. <br /> , <br /> CHATSW TH � <br /> 2� SAWCUT AND REMOVE FLOOR SLAB DOWN TO SOIL <br /> ENCLOS E � AFTER IMAGING SLAB TO LOCATE EXISTING <br /> 5 CONDUITS/PIPING. <br /> � 28b � 2 � INSTALL NEW FLOOR BOX HUBBELL �B2506 SERIES <br /> �. 30c 37 WASH FOUNTAIN � WITH BRASS COVER. <br /> I � 120V 1� <br /> 37 � � INSTALL NEMA 5-15R RECEPTACLE IN PONY WALL. <br /> I 3 COORDINATE EXACT BUTTON WITH WASH FOUNTAIN <br /> � SHOP DRAWINGS. <br /> I r <br /> - - 1 � 2 � INSTALL PVC COATED RIGID CONDUIT. <br /> 11 13 FLUSH <br /> �2� � 29 1 T VALVES 120V 6 CONNECT TO EXISTING BRANCH CIRCUITS. <br /> � (TYP -0 F �-) - - � <br /> � m � � � m m m m o 5 39 I <br /> 2V37-02C12/4 2V37-02C12/2,4 2V37-02C10RP4/29c T 9 2 5 7� PROVIDE 20A-1P GFCI BREAKER TO SERVE WASH <br /> 3/4 C 2#12 #12G 3/4 C 4#12 �12G 1E6 E540 I g 12 � FOUNTAIN, FLUSH VALVES AND SENSOR FAUCETS <br /> I I (CIRCUITS 37 & 39). <br /> � <br /> = I I � 8� INSTALL AND WIRE TRANSFORMER (PROVIDED BY <br /> I EXP 2a � _ _ _ I _ MECHANICAL) IN FLUSH ENCLOSURE BELOW SINK. <br /> I <br /> 4 39 9� INSTALL AND WIRE TRANSFORMER (PROVIDED BY <br /> _ MECHANICAL) IN SURFACE MOUNTED ENCLOSURE. <br /> WASH FOUNTA 10 PROVIDE 1/2"-2�16 FROM IR FAUCET TO <br /> TRANSFORMER. <br /> � 120V-1� <br /> � T PANEL - T 10 11 PROVIDE 1/2"-2#16 FROM FLUSH VALVES TO <br /> � 2 37-02C14RP2 12 TRANSFORMER. <br /> w .- C T. 38a 41 c . <br /> z � SENS R FAUCET 1� REWIRE FROM CIRCUIT 39 TO CIRCUIT 41 . <br /> � ( � EXP 6� % 120V (TYP 2) <br /> �- - �-, 13 RE-FEED EXISTING RECEPTACLES. <br /> � , i , <br /> R A B C D <br /> 41c <br /> 2V37-02C12/6 EXP '- �, <br /> 3/4"C 2#12 #12G <br /> 2 14 <br /> � m � m m EXP �8a m � m o 38a MATCH LINE ' <br /> SEE�HT. I 39 �� 1 E60 1 E61 1 E62 <br /> - — �— i — , <br /> � � � _ _ 13 <br /> 1E63 i 1E64 � 65 12 <br /> 1E72 — — <br /> 1E66 1E67 1E68 11 <br /> PART AL 120 208� POWER P �AN 1E69 ,E�o 1E71 <br /> SCALE: 1/8" =1 '-0" N OFFMAN W5741115 �o' <br /> N G I N E E R S PHASE 1 RENOVATION PACKAGE KEY PLAN �sEcr�o�R\ <br /> 1101 2nd Ave.,Suite 400�Seattle,WA 98101 � 4� 8' 16' 2 4' N.T.S. N DETAIL NUMBER <br /> ph 206.623.0717�fax 206.624.3775 I F C S U B M I TTAL <br /> coffman.com 07.02.1$ &EDET�AIL TA EN SHO N <br /> LASTING creativity�results�relationships FROM ON <br /> KEY N , <br /> SYM REVI510N BY APPROVED DATE SYM REVISION BY APPROVED DATE J� DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE � <br /> yS • tL � N�S ACCEPTABILITY D.MELLNICK 3 92 W5741115 E 07.02.18 " <br /> A CENTRAL AMMONIA SYSTEM 977017 AKC 03/94 �1'� ��t �f�� r THIS DESIGN AND/OR CHECKED PARTIAL 1 ST FLOOR 120/208V POWER PLAN � <br /> � -> r SPECIFICATION IS APPROVED B.KNAGGS 3 92 SHEEf \ <br /> B SHOP REARRANGEMENT 1001330082 BWC 08.10.04 BOE,�� � � 1 � APPROVED BY DEPT. DATE A.BREWTON 3 92 TITLE WORKPLACE ENVIRONMENT INVESTMENT 1 E E 1 c <br /> CHECKED 6 5 � � <br /> C 100Mb TECH REFRESH 578917-54 JRL KR�WL 07.13.08 A.BREWTON 4�93 B U I LD I N G 40'O�� a <br /> APPROVED <br /> JOB N0. COMP N0. <br /> D ROBOT UTILITIES W4028096 SJO KER/MNH 01.28.16 �� r�f , �;j w�~ A.BREWTON 4/93 W4028096 n <br /> �c�, �t.���rt.'� �: <br /> E RESTROOM RENOVATION � D13 W5741115 CEI PWJ 07.02.18 S'S L�cs L.ELLISE� 4/93 ELECTRICAL MASTER COL. C-D/12-13 SITE °wc No. 40-37-1 E65 <br /> 6/27/2018 <br />