Laserfiche WebLink
work are 20 minute assemblies. In the two locations where <br />glazing is shown on an exit corridor, the area of glazing is <br />significant less than 25% of the area of the common wall. and <br />are wire glass conforming to 3/4 hr. rated assembly. <br />6. The change to the Conference/Break Room eliminates the <br />rear corridor. As a precaution, I have created a rated <br />enclosure at the rear exit. <br />7. 1 have added a separation wall and door #29 on the second <br />floor between the elevator and the corridor, creating an <br />enclosed elevator lobby. This correction is shown on sheet <br />A-2. <br />8. 1 have clarified the label for the Equipment Room on sheet A-1 <br />by changing it to say 'Computer' Equipment Room. Since the <br />room requires no special separation, none is provided. <br />9. - All doorways leading to accessible rooms have an <br />unobstructed clear width of not less than 32 inches. No <br />adjustments were required to meet this requirement. <br />10. I have changed the width of the corridor approaching door <br />#27 on the second floor to provide the required maneuvering <br />Blaines1 S1 clearances. This correction is shown on sheet A-2. <br />a�Se <br />SedIlle , <br />WN 96119 <br />