My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2821
>
NW TELCO
>
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 8:32:43 AM
Creation date
4/12/2019 8:32:26 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2821
Tenant Name
NW TELCO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � <br /> I <br /> � <br /> � <br /> f� � <br /> � FIRE PROTECTION <br /> '� CONTROL UNIT <br /> , l-•• _ '-�' P/N 30-222000-001 <br /> PROTECTION SYSTEMS DIVISIO�! ' �sso-oas <br /> ' � EMective:March, 1988 <br /> GENERAL FEATURES <br /> � ' • Fully Regulated Power Supply <br /> � • Buiit-In Battery Charger& Batteries <br /> � : <br /> • Ground Fault Supervision <br /> ; • • Trouble Isolation Fault Indicators <br /> ; • Solid State Circuitry <br /> ` • UL Listed to Standard 864 � 1lLEASE <br /> • Panel Mounted Abort and Release Switches '°""' "`""" <br /> , . • • <br /> ; • Transient and Noise Isolation � <br /> ADDITIONAL FEATURES A �+ s�ro, <br /> • Class"B"Alarm Detection Circuits `1��„ w ,r+�a�E <br /> • Supervised Poiarity Reversing Output for. <br /> Pre-Alarm <br /> Pre-Release <br /> ; Release Signals <br /> • Auxiliary Contacts for Troubie and Alarm Signals <br /> • Releasing Output for Initiators or 24 VDC Actuator <br /> ! • Field Selectable Time Delays <br /> , � • • Supervised Abort Circuit �Q <br /> • Differentiates between Fenwai Smoke Detectors and -4, �'u.e <br /> Contact Devices on Same Detection Circuit • ��.w� <br /> • Ease of Wiring <br /> • Supervised Loop tor Closed Circuit Contacts <br /> ' GENERAL <br /> � This low cost, versatile single zone Control Unit super- and a continuous release signal is triggered unless the <br /> vises one Halon 1301 fire protection system. It meets the system abort teature has been enabled. <br /> ` requirements of NFPA Standard 72A and is UL Listed per A contact device in either detection circuit will trigger the <br /> Slandard 864. State•of-the-art solid state circuitry pro- release signals releasing the extinguishant. <br /> vides increased protection from transients and noise while <br /> increasing reliabiliry. ALARMS <br /> - A single three-level alarm output circuit is Class"B"super- <br /> DETECTION vised and operates polarized signalling devices. An inde- <br /> A special feature of this unit is the abiiiry to ditferentiate pendent dry Form C auxiliary relay contact is associated <br /> between two-wire smoke detectors and contact rype alarm With each output function. <br /> actuators on the same detection circuit,simpiifying instal- An Alarm Silence Switch located on the module board will � <br /> lation and reducing wiring costs.The suppression module silence the alarm signal output; however, a subsequent <br /> . has two independent aiarm detection circuits which are alarm will override the Alz•m Silence Switch. <br /> wired for Class"B"operation.Up to 5 Fenwal 24 VDC ioni- <br /> • zationorphotoelectricsmokedetectorsmaybeconnected EXTINGUISHING AGENT RELEASE <br /> to each circuit. Contact devices such as Fenwal's The Control Unit drives either initiator or 1-i/2" pilot re- <br /> � DETECT-A-FIRE^ heat detectors or manual pull stations tease valve so the unit is compatible with either Fenwal <br /> also may be connected in the same circuit.Total lead wire Moduiar or Centrat Storage extinguishing systems. Re- <br /> resistance of 25 ohms allows extended detection circuit lease circuit will actuate either two electro-explosive in- <br /> wire runs. itiators (Fenwal P/N 31-199932-OOX) or one 24 VDC ac- <br /> � A single smoke detector in either of the two detection cir- tuator on ASC (Fenwal PM 31-19203X•OOX) with 1-1/2" <br /> � cuits initiates a Pre-Alarm signal.When a smoke detector P�lot release valve. <br /> � • in both loops of the control unit is in alarm,a Pre-Release WARNING: Release circult !s not compatlble wlth <br /> signal is generated and time delay circuit,ii used,will acti- Fenwal P/N 31•19203X-XXX 2" Pllot Release Valve <br /> Ivate. When the time delay is satisfied, agent is released Tanks and 31•19204X•XXX 3"Burst Dlsc Valve Tanka. <br /> �_ <br /> � - <br />
The URL can be used to link to this page
Your browser does not support the video tag.