My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2821
>
NW TELCO
>
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 8:32:43 AM
Creation date
4/12/2019 8:32:26 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2821
Tenant Name
NW TELCO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> ; <br /> i <br /> ABORT SWITCH RELEASE CIRCUIT CONFIGURATIONS r <br /> A Supervised Abort Switch is mounted on the Control Unit ��,,,�„�,� <br /> door.While the button is depressed,agent release is pre- "^°�' <br /> vented but alarms continue to sound.A contact device ac FlGURe u ��_(�I <br /> tuation overrides the Abort Switch and time delays to re- one zavoC Acweror t_t:i �i� � <br /> P/N 31-194135•001 or _I-=' <br /> 1885@89@M. 31-194135-002 9� p <br /> Term.9 to 10 """„°, �-- 101 FJ <br /> TIME DELAY f osw.�M,�,a...»���na.,..�.z. ' <br /> ro u�o-�n.�m.m..a��mm�on <br /> Control Unit can be programmed tor 20 or 40 seconds <br /> delay between pre-release and agent release. Abort FIGURE 18 ' <br /> switch actuation shall not prevent time out of delay. Re- Comiyura�ionwim 00nC""'"°""'-"� <br /> lease of abort to normal position shall result in agent re- aeiease Circui� �.,,� n � <br /> lease if panel is in pre-release.time delay has elapsed and Usetl to Fire — Bi � <br /> Initiators PIN 37-799932•OOX <br /> panel has not been properly reset. iniiiamr c�rcuic ;,`;;;o;�y '91 <br /> � ' Supen�isoryCurrenC w,. —101 <br /> � P.Sf1�A. D.C. t OSW�hM�n IA�Mu�4r:�eaanuncr !'. <br /> SUPERVISION 7otalEnergy:3.OJoules �o��o=�n»�'^^^u��^� 1 <br /> The Control Unit is fully supervised. Supervision includes „ <br /> but is not limited to the following: <br /> • AC Powsr • abort switch circuit •• <br /> • batteryvoltage • releasingoutputs <br /> � • batteryconnections • groundtault yyppNlNG: RNawelreultbnotcompaqEle " <br /> • alarm detection circuits • pressure switch(NC) wlth F�nwal PIN 91-19203%-X%X 2' j, <br /> • alarm output Pllot RN�au Wlw T�nks entl <br /> 91-19201X-XXX 3'Burnt Dlse Valve <br /> The Control Unit includes four indicators visible with the reak■ " <br /> enclosure door closed (AC Power, Alarm. Alarm silence. �� <br /> a <br /> ` System trouble). Additional LED trouble indicators are NOTES: „ <br /> ' located on the module printed circuit board as shown in Alarm Output: <br /> ' t Use only polanzed signallinq devices. • <br /> Figure 1. _ <br /> i ?. Polari0es shown are lor normal stantlby. _ <br /> 3. TotalSystemCurremshallnotexceetl0.2ADCat <br /> 2aVDC. <br /> TROUBLE INDICATION i, Supervisory Currenc 2 MA <br /> Trouble conditions result in an audible signal and illumina- Rei�y ou�pu�e: �` <br /> tion of an LED annunciator on the affected circuiL The au- s. �u reiay concaccs snown wnn power apPuea�n <br /> dible signal may be silenced by ihe Trouble-Silence normal stand�y conCition. <br /> Switch on the module panel. Fault isolation is facilitated by Tima Delay: �� <br /> el ht trouble indicators and a trouble rin back. A trouble 6. This uNt may be lield programmed lor release + <br /> g 9 time ae�ays o�20 or ao seconds. <br /> condition activates a set of dry Form C contacts, yyi�i„y; <br /> � ;. All wiring ro initiaror output and detection circwis <br /> � must be shieldetl or electrically isolated trom all . <br /> POWER SUPPLY otherwiring Shie'leaconductors.Mlcable.EMT. <br /> or rigid conduit may be used.Compliance will ail <br /> The Control Unit contains a 24 VDC regulated power sup- national and local Iire cotles is required. I <br /> ply with overload protection provided by electronic current rowar. - , <br /> limiting.A fuse is utilized in the battery circuit only.A Class 8. 120VAC SO/60Hz with Banery Stantlby. � <br /> II design transformer protects AC i,�put. Inieletor�l24voc Actuetor Rsleese clrcuit: , <br /> 9. ThereleasecircuRwillenergizelorapproximarely <br /> The control module contains a built•in battery charger and 200 m.s.on initietorrelease system.AttheenC ot . <br /> 1 set of 1.2 ampere/hour sealed lead acid batteries che 200 m.s.the release arcuits will de•energize. <br /> housed within the control unit enclosure. A trouble signal <br /> is generated if battery volta9e drops below acceptable - <br /> 18V@IS. � Contml unit features not applicable tor connection ol <br /> Iwaterllow alarm tlevices. <br /> ENCLOSURE ` � <br /> The panel enclosure is rugged 18 gauce steel and is � <br /> painted beige. A steel door is held closeC hy a key lock. <br /> All switches and indicators, with the exception of Manual - <br /> Reiease and Abort Switch, are located behind the locked <br /> cover. ' ' <br /> i <br /> 2 � <br />