My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
>
Address Records
>
HEWITT AVE
>
2821
>
NW TELCO
>
2821 HEWITT AVE NW TELCO 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 8:32:43 AM
Creation date
4/12/2019 8:32:26 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2821
Tenant Name
NW TELCO
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II <br /> � <br /> I <br /> 1 <br /> OPERATING INSTRUCTIONS AIARM SILENCE SWITCH 1 , <br /> NORMAL STANDBY Sil�nces audibie and visual alarm devices. Receipt of a i <br /> sutsequent alarm will reactivate the alarm outputs. <br /> Green —AC "On" Indicaror shaii illuminate through panel � ', <br /> door. All other indicators shall be extinguished. Momentary action switch returns to Normal position when <br /> ALARM—CIRCUIT 1 6 2 released. but alarm outputs remain silenced until sub- '� <br /> Red—ALARM CIRCUIT Indicator shall illuminate through sequent alarm is received andlor Reset switch is acti• <br /> panel door,indicating activation of detection device or ac- vated. <br /> tivation of manual release switch mounted on panel door. SUPERVISORY TR�UBLE ANNUNCIATOR <br /> PRE-ALAFiM SIGNAL—Audible Amber indicator illuminates inside panel if closed contact <br /> Activates when Detection Circuit 1 or Detection Circuit 2 loop circuit (i.e. pressure swiich) opens during normal <br /> activates 1/2 second on,2-1/2 seconds oif. standby condition. <br /> PRE-RELEASE SIGNAL—Audible TESTING RECOMMENDATIONS <br /> Activates when Detection Circuit t and Detection Circuit 2 At least once a week or as required by local authoritiea <br /> are activated by smoke detectors connected to both alarm having jurisdiction, the following testing program should <br /> detection circuits. 1 second on, t second off. be conducted. <br /> RELEASESIGNAL—Audible t. Depress Alarm Test Switch to Test position and ob- <br /> serve operation of Audible and Visual Alarm devices. <br /> : Activates immediately upon activation of extinguishing 2 perform Battery Maintenance procedure as outlined <br /> agent release output—on continuously. below. <br /> NOTE: Operation ot Manual release switch or conta;r FUSE REPLACEMENT <br /> rype detection devices (DAF. etc.) connecte�l to The battery circuit is protected by a 5A Type 3 AG glass <br /> either Alarm Detection Circuit 1 or 2 will act vate cartridge fuse.Replace only with a fuse of the same rating. <br /> release lunctions. Should service be required,contact your local service rep- <br /> SYSTEM TROUBLE ANNUNCIATOR resentative. <br /> Amber Indicator illuminates through panel door whtn a BATTERY MAINTENANCE <br /> trouble condition exists in any of the system supervi�,d The following testing program should be conducted at <br /> circuits. least once a week, or as required by locai inspection au- <br /> GROUND FAULT ANNUNCIATOR thorities having jurisdiction. <br /> Amber indicator inside panel illuminates when a grouna Disconnect AC power and silence trouble. <br /> fault that could intertere with system operation exists. ' <br /> DETECTION CIRCUIT TROUBLE ANNUNCIATOR Actuate Alarm test switch to test positiun. If Ammeter is <br /> Amber indicator iiluminates inside panel when a trouble connected,it should momentarily indicate 120-300mA and <br /> condition exists in alarm detection circuit 1 andlor 2. Battery Trouble indicator should not light. It voltmeter is <br /> used in lieu of ammeter, voltmeter should read 21.5 volt� <br /> RELEASE AND SIGNAL OUTPUT CIRCUIT TROUBLE minimum and then return to 24 volts minimum. <br /> ANNUNCIATOR Failure of the ammeter to indicate 120-300mA and/or fs.il- <br /> Amber indicator illuminates inside panel when a trouble ure oi the voltmeter to register 21.5 volts minimum, or il- <br /> condition exists in Ihe supervised agent release or alarm �umination of the Batterv Trouble indicator indicates insuf- <br /> output circuit. ' <br /> ficient battery capacity. <br /> ALARM SILENCE ANNUNCIATOR <br /> Amber i�dicator illuminates through panel door when NOTE: If arolonged AC power lailure has occurrecl <br /> alarm silence switch has been actuated and an alarm con- within 20 hours o/bariery test, allow a[least 20 hour:: <br /> dition exists. /or the battery to recharge before taking lurther action. � <br /> BATTERY TROUBLE ANNUNCIATOR ; <br /> Amber indicator illuminates inside panel when a fault � <br /> exists in the supervised battery circuit and illuminates if RECOMMENDED WIRING COLOR CODE FOR � <br /> battery voltage falls below acceptable limits. HALON 1301 FIRE SUPPRESSION INSTALLATIONB� ' <br /> BATTERYPOLARITYANNUNCIATOR WIRINGCOLORCODE (SINGLECONDUCTORWIRES) I <br /> Amber indicator illuminates inside panel it battery is con- 'Black = BK forAC power hot <br /> nected with improper polarity, extinguishes when polariry 'White = WH AC neutral <br /> is corrected. 'Green = GR ground <br /> ALARM TEST SWITCH 'Mandatory per N.E.C. <br /> Activates Pre-alarm audible — visual signalling circuit. WIRE SIZES <br /> Momentary action switch retums to Normal position when AC powerfeed #14 minimum(#12 max.) <br /> released. Allothers #14,16or18 <br /> ABORT TROUBLE ANNUNCIATOR If aRer 20 hours total recharge a failure indication occur:�, <br /> Amber indicator illuminates inside panel if abort circuit replace the batteries with the same rype and capacit�. <br /> opens during normal standby condition. Batteries originally furnished by Fenwal are:2 ea. Fenwcd <br /> a <br /> � <br /> - � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.