Laserfiche WebLink
f <br /> �� <br /> � <br /> , <br /> i <br /> � P/N 30-220070•039, rated �2V, 12 AH. Replace in pairs TECHNICAI SPECIFICATIONS <br /> only to assure maximum capaciry. (Note Fenwal P/N 30- CompaNbil(ty Identifier Number:C20FE1 <br /> 220070-039 denotes a pair of batteries.) Power Supply: <br /> BATTERY POWER Input: 120 VAC, 50/60 Hz,02A max. <br /> � •.` - Batteries provide 24 hours standby supervision plus 5 mi- putputs: <br /> � � nutes alarm load at the end of tha!time contingent upon polarity Reversing Alarm Signals(1): Rated 24-25 <br /> *■ detection and output limitation stated herein. Panel load- VDC,02A max. <br /> .: ` ing and battery standby comply with NFPA Standard 72A. puxiliary PrrAlarm relay contact(1):Form C rated <br /> 2A max.24 VDC or 1 A 120 VAC <br /> r NOTE: Batteries supplied with control panel shall be i <br /> � r+or placed in service within 3 months o/shipment date ii Auxiliary Pre-Releaae relay contact (t): Form C <br /> ?AMf stored at approximately 70°F, or within one month i/ �ated 2A max. 24 VDC or 1.4 120 VAC <br /> � storedatapproximately 100°F. Forlongerstoragetime AuxUlary Reisass relay contact (1): Form C rated i <br /> they require charging per manutacturers specification 2A max. 24 VDC or 7 A 120 VAC <br /> ur�+us to prevent permanent loss ol capaciry. i Auxfliary Trouble Relay Contact (1): Form C rated � <br /> :UMPERn 2A max. 24 VDC or 1A 120 VAC <br /> , � �lOd�0070 ; <br /> Initietor Output: � <br /> CAUTION: Total Loop Resistance: 10.0 ohms <br /> � To avoid damaging the power supply,lirst connect DC ; Total Energy Avallable:3.0 J <br /> r power, observing proper battery polariry. Should the ', Supervlaory Current:2.SmA <br /> � battery polariry reversal LED be illumina[ed, correct <br /> � ! � battery polariry before applying AC power. � Actuator Device: 1 —PM 31-194135-OOX <br /> t Be%re servicing batteries, disconnect AC power. Baf- � Maximum EED Devices: 2—P/N 31-199932-004 <br /> f � teries should be replaced at least once every 48 i Detection Circuits: <br /> � � � months, or as directed by the local authorities having ; Output Voltage: 24.0 to 27.0 VDC <br /> � jurisdiction. , Maximum number twawire smoke detectora per I <br /> � circuit: 5 Detector?ypes: Fenwal 24 VDC, <br /> � 7021, 71XX <br /> � : . <br /> INSTALLATION INSTRUCTIONS MeximumnumberContactDevices:Upto25ohmswire <br /> INSTRUCTIONS FOR MOUNTING resistance <br /> � ` (REFERENCE FIGURE 2) Meximum Contact Device <br /> 1. Remove knockouts at top and bottom as required. Alarm Current:75 mA � <br /> � 2. Insert number i0 screws (not provided) into wall. End-of•Line Reaiators: <br /> spaced to match key holes on back of box. Detection Circuita: 10K ohms 1/2W, 2 turnished <br /> 3. Mount bax onto the screws. Signelling Circuft:3.OK ohms 1I2W. 1 turnished <br /> ( 4, Insert number 10 screws in remaining two holes in the Meter Test Pointa: Ammeter or Voltmeter <br /> i bottom oi the box and tighten all screws. Standby Betterles: <br /> 5. See installation wiring diagram for turther instructions. Sealed Lead Acid: 2-12V. 1.2 AH (std.) <br /> � Battery Recherge Time: 20 hours minimum from deep <br /> discharge <br /> � Bettery Standby Time: See Battery Power <br /> Time Delays per Module:20 or 40 seconds, field <br /> KNOCNOUTS SeleCtable. <br /> ■■■ -�' See Programming Instructions. <br /> ■. � �V Dimensfons(nominal): 14"H x 12"W x 3-3/4"D <br /> . , ��� <br /> � ° � m ° � ' I ORDERING INFORMATION <br /> � o aa <br /> ' ° � °a °o o Deeerlption Part Number <br /> � � Model 2220 Single Zone Control Panel 30-222000-001 <br /> �;i o , w/Battery Bracket and containing: <br /> � � �� Two 12V,1.2 AH Sealed Lead Acid Batteries 30420070-039 <br /> �,. . � n Battery Hamess for above Battery Set 30-220070•036 <br /> '� �� ' " Component Board Panel Ass'y 30•222000-701 <br /> � KNOCKOUTS � � Accessory Kit(Resistors) 30-220070•033 <br /> f FIGURE 2 <br /> •' S <br /> .. . _ . _ ... . . . . . . — � <br /> ( <br />