My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3927 RUCKER AVE 2ND FLOOR 2019-04-17
>
Address Records
>
RUCKER AVE
>
3927
>
2ND FLOOR
>
3927 RUCKER AVE 2ND FLOOR 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 7:27:00 AM
Creation date
4/17/2019 7:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Ectrical Permit Checklist, Pg. LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: The Everett Clinic-Hand Therapy Remodel Date 8/30/2018 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method on plans <br /> Yes C405.2 general for spaces and lighting zone(s)served,or exception taken Sheet A-131 <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of <br /> NA C405.2 lighting controls C405.2 lighting controls;provide description of control <br /> (LLLC) capabilities and performance parameters <br /> For permanently installed lighting fixtures in dwelling units, <br /> NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and <br /> units lighting zone(s)served,or demonstrate compliance with high <br /> efficacy exception <br /> C405.2.3 Indicate on plans the method of manual lighting control(whether <br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction, <br /> Yes C405.2.2.2 Manual controls Sheet A-131 <br /> C405.2.4 daylight responsive or specific application controls),location of <br /> C405:2:5 manual control device and area or specific application it serves <br /> C405.2.2.1 Indicate on plans which method of manual 50%lighting load <br /> NA C405.2.2.2 Manual interior light reduction is provided,or whether lighting load is reduced via Sheet A-131 <br /> C405.2.3 reduction controls occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control <br /> during unoccupied periods(occupancy sensor,time switch or Sheet A-131 <br /> NA C405.2.2 Method of automatic digital timer switch)for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which <br /> time switch control exception applies <br /> Sheet A-131- <br /> Indicate on plans the spaces served by occupancy sensors; Exempt <br /> NA C405.2.1 Occupancy sensor healthcare <br /> C405.2.1.1 controls Indicate whether occupancy sensor controls are configured to Sheet A-131- <br /> be manual-on,automatic 50%-on,or serve a space eligible for Exempt <br /> automatic 100%-on per exception healthcare <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting <br /> warehouses power by 50% <br /> NA C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting <br /> switch controls zone(s)served,include area sq.ft. <br /> NA C405.2.6 Digital timer switch Indicate digital timer switch control includes:manual on/off,time <br /> delay,audible and visual indication of impending time-out <br /> Indicate primary and secondary sidelight daylight zone areas on Exempt- <br /> plans,include sq.ft.; healthcare <br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include sq.ft.; NA <br /> NA C405.2.4.3 Sidelight and toplight For small vertical fenestration assemblies(rough opening less <br /> than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area <br /> to daylight zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive Exempt- <br /> controls; healthcare <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s) NA <br /> NA C405.2.4 Daylight responsive that apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least <br /> two even steps between 0%-100%of rated power; <br /> Indicate that daylight sensing controls are configured to <br /> completely shut off all controlled lights in the lighting zone <br /> Additional controls Identify spaces and lighting fixtures on plans that require <br /> NA C405.2.5 Specific application specific application lighting controls per this section <br /> lighting controls <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent case lighting are controlled independently from both general <br /> NA Items 1&2 lighting area lighting and other lighting applications within the same <br /> space; <br /> Indicate manual and automatic lighting control method <br /> "„), <br /> s � � <br />
The URL can be used to link to this page
Your browser does not support the video tag.