My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3927 RUCKER AVE 2ND FLOOR 2019-04-17
>
Address Records
>
RUCKER AVE
>
3927
>
2ND FLOOR
>
3927 RUCKER AVE 2ND FLOOR 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 7:27:00 AM
Creation date
4/17/2019 7:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: The Everett Clinic-Hand Therapy Remodel Date 8/30/2018 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NA Item 3rooms control of all installed luminaires and switched receptacles in <br /> guest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> YES control for supplemental task lighting,including under-shelf or Sheet A-131 <br /> Item 4 lighting <br /> under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, <br /> include sq.ft.area of each lighting control zone; <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NA Item 5 visual applications independently from both general area lighting and other lighting <br /> applications within the same space; <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or <br /> Lighting equipment demonstration are controlled independently from both general <br /> C405.2.5- area lighting and other lighting applications within the same <br /> NA for sale or <br /> Item 6 space; <br /> demonstration <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal <br /> and emergency means of egress illumination; <br /> Provide calculation of lighting power density of total egress <br /> NA C405.2.5- Means of egress lighting; <br /> Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq. <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off control <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and <br /> locations served; <br /> For building facade and landscape lighting,indicate automatic <br /> Exterior lighting controls shut off lighting as a function of dawn/dusk and fixed <br /> NA C405.2.7 opening/closing time; <br /> controls <br /> For all other exterior lighting,indicate automatic controls shut off <br /> lighting as a function of available daylight;include control <br /> sequence that also reduces lighting power by at least 30% <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate on <br /> NA C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or; <br /> controls are controlled by motion sensor,or are exempt lighting per <br /> C405.5.2 <br /> Area controls- Indicate location(s)of master control switch(es)intended to <br /> C405.2.5 Master control control multiple independent switches;circuit breaker may not Not in Scope <br /> Yes (listed after be used as a master control switch; <br /> switches and circuit <br /> C405.2.7) power limit Verify that no 20 amp circuit controlled by a single switch or Sheet A-131 <br /> automatic control is loaded beyond 80% <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION-ENHANCED DIGITAL LIGHTING CONTROLS <br /> To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed <br /> NA C406.4 <br /> Enhanced digital and provided with continuous dimming,or exception taken; <br /> lighting controls Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control <br /> functions(min 90%to comply with additional efficiency package <br /> option) <br /> � l� <br />
The URL can be used to link to this page
Your browser does not support the video tag.