My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3927 RUCKER AVE 2ND FLOOR 2019-04-17
>
Address Records
>
RUCKER AVE
>
3927
>
2ND FLOOR
>
3927 RUCKER AVE 2ND FLOOR 2019-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2019 7:27:00 AM
Creation date
4/17/2019 7:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> 4 <br /> Lighting Summary, cent. LTG-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: The Everett Clinic-Hand Therapy Remodel Date 8/30/2018 <br /> Change of Space Use ❑ Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2). <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table <br /> in LTG-INT-BLD or LTG-INT-SPACE form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced Q ❑ ❑ <br /> Select all Lighting Power and Lighting Less than 50%of existing are replaced ❑ ❑ ❑ <br /> Control elements that apply to the scope <br /> of the retrofit project.If project includes a <br /> combination of spaces where less than Lamp and/or ballast replacement only <br /> 50%of the existing fixtures are replaced —existing total wattage not increased ❑ ❑ ❑ <br /> in some spaces,and 50%or more of the 50%or more replaced-Total lighting power of new+existing-to-remain fixtures shall comply with total <br /> fixtures are replaced in others,then LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-remain fixtures in Proposed <br /> provide separate lighting power Lighting Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> compliance forms for the two retrofit a <br /> conditions.Spaces undergoing the same Less than 50%replaced-Total lighting power of new+existing-to-remain fixtures shall not exceed the <br /> type of retrofit may be combined into one total lighting power prior to alteration. Include new+existing-to-remain fixtures in the Proposed Lighting <br /> lighting power compliance form. Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages,and total <br /> Refer to Section C503.6 for additional installed wattage for exterior luminaires. <br /> requirements. <br /> Lighting Controls Interior lighting Parking garage Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added <br /> commissioned per C408.3. fixtures and/or fixtures relocated to new ❑I ❑ ❑ <br /> circuit(s) <br /> New or moved lighting panel ❑ ❑ ❑ <br /> Interior space is reconfigured- ❑ <br /> luminaires unchanged or relocated only <br /> New wiring or circuit-For interior lighting,provide required manual controls per C405.2.3,occupancy <br /> sensor controls per C405.2.1,daylight responsive controls per C405.2.4 and application specific lighting <br /> No changes are being made to controls per C405.2.5.For exterior lighting,provide required controls per C405.2.7. <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2. <br /> uses and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior space. <br /> changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. <br /> C/ /° <br />
The URL can be used to link to this page
Your browser does not support the video tag.